1 – 10 of 17Hassan Th. Alassafi, Khalid S. Al-Gahtani, Abdulmohsen S. Almohsen and Abdullah M. Alsugair
Heating, ventilating, air-conditioning and cooling (HVAC) systems are crucial in daily health-care facility services. Design-related defects can lead to maintenance issues…
Abstract
Purpose
Heating, ventilating, air-conditioning and cooling (HVAC) systems are crucial in daily health-care facility services. Design-related defects can lead to maintenance issues, causing service disruptions and cost overruns. These defects can be avoided if a link between the early design stages and maintenance feedback is established. This study aims to use experts’ experience in HVAC maintenance in health-care facilities to list and evaluate the risk of each maintenance issue caused by a design defect, supported by the literature.
Design/methodology/approach
Following semistructured interviews with experts, 41 maintenance issues were identified as the most encountered issues. Subsequently, a survey was conducted in which 44 participants evaluated the probability and impact of each design-caused issue.
Findings
Chillers were identified as the HVAC components most prone to design defects and cost impact. However, air distribution ducts and air handling units are the most critical HVAC components for maintaining healthy conditions inside health-care facilities.
Research limitations/implications
The unavailability of comprehensive data on the cost impacts of all design-related defects from multiple health-care facilities limits the ability of HVAC designers to furnish case studies and quantitative approaches.
Originality/value
This study helps HVAC designers acquire prior knowledge of decisions that may have led to unnecessary and avoidable maintenance. These design-related maintenance issues may cause unfavorable health and cost consequences.
Details
Keywords
Shichao Jiang, Xinliang Lu, Hongliang Wang, Kai Song and Yuanyuan Jiang
Detection of hidden defects of aluminum alloy plate with damping coating is a challenging problem. At present, only a few non-destructive testing methods exist to address this…
Abstract
Purpose
Detection of hidden defects of aluminum alloy plate with damping coating is a challenging problem. At present, only a few non-destructive testing methods exist to address this engineering problem. Without the restriction of skin effect, remote field eddy current (RFEC) overcomes the interference caused by the damping coating. The RFEC, which has potential advantages for detecting the hidden defects of aluminum plate with damping coating, can penetrate the metal plate to detect buried depth defects. This study aims to test how thick the RFEC sensor can penetrate the metal plate to detect the buried defects.
Design/methodology/approach
The magnetic field distribution characteristics are analyzed, the magnetic field intensity distribution is calculated, and the structure and parameters of the coil, magnetic circuit and shielding damping are determined through the two- and three-dimensional finite element simulation methods. Optimal excitation frequency is obtained, and the distance between the excitation coil and detection coil is determined by analyzing the relationship between excitation frequency and remote field points.
Findings
Simulation and experimental results verify the feasibility of applying the RFEC detection technology in detecting the hidden defects of aluminum alloy plate with damping coating.
Originality/value
In this paper, the RFEC testing model of hidden defects in aluminum plate sample with damping coating is established by using the finite element method.