Search results
1 – 10 of 443Neno Toric, Rui Rui Sun and Ian W. Burgess
This paper aims to propose a methodology to remove inherent implicit creep from the Eurocode 3 material model for steel and to present a creep-free analysis on simply supported…
Abstract
Purpose
This paper aims to propose a methodology to remove inherent implicit creep from the Eurocode 3 material model for steel and to present a creep-free analysis on simply supported steel members.
Design/methodology/approach
Most of the available material models of steel are based on transient coupon tests, which inherently include creep strain associated with particular heating rates and load ratios.
Findings
The creep-free analysis aims to reveal the influence of implicit creep by investigating the behaviour of simply supported steel beams and columns exposed to various heating regimes. The paper further evaluates the implicit consideration of creep in the Eurocode 3 steel material model.
Originality/value
A modified Eurocode 3 carbon steel material model for creep-free analysis is proposed for general structural fire engineering analysis.
Details
Keywords
Osama A.B. Hassan and Christopher Johansson
This paper aims to compare glued laminated timber and steel beams with respect to structural design, manufacturing and assembly costs and the amount of greenhouse gas emissions.
Abstract
Purpose
This paper aims to compare glued laminated timber and steel beams with respect to structural design, manufacturing and assembly costs and the amount of greenhouse gas emissions.
Design/methodology/approach
This paper presents structural design requirements in conformance with EN 1993: Eurocode 5 and Eurocode 3. With the help of these standards, expressions are derived to evaluate the design criteria of the beams. Based on the results of life-cycle analysis, the economic properties and environmental impact of the two types of beam are investigated. In this paper, the effect of beam span on the design values, costs and carbon dioxide emissions is analysed when investigating aspects of the structural design, economy and environmental impact. Different cross-sections are chosen for this purpose.
Findings
The study shows that the glued laminated (abbreviated as “glulam”) beams have a smaller tendency to lateral torsional buckling than the steel beams, and that they can be cheaper. From an environmental point of view, glulam beams are the more environmentally friendly option of the two beam materials. Furthermore, glulam beams may have a direct positive effect on the environment, considering the carbon storage capacity of the wood. The disadvantage of glued wood is that larger dimensions are sometimes required.
Research limitations/implications
Wind load and the effect of second-order effects have not been considered when analysing the static design. Only straight beams have been studied. Furthermore, the dynamic design of the beams has not been investigated, and the bearing pressure capacity of the supports has not been analyzed. We have investigated timber beams with a rectangular cross-section, and steel beams of rolled I-sections, known as “HEA profiles”. The cost analysis is based mainly on the manufacturing and assembly costs prevalent on the Swedish market. The only environmental impact investigated has been the emission of greenhouse gases. The design calculations are based on the European standards Eurocode 5 and Eurocode 3.
Practical implications
To achieve sustainability in construction engineering, it is important to study the environmental and economic consequences of the building elements. By combining these two effects with the technical design of buildings made of steel and/or timber, the concept of sustainable development can be achieved in the long run.
Social implications
The study concerns sustainability of building structures, which is an important of the sustainable development of the society.
Originality/value
The paper contains new information and will be useful to researchers and civil engineers.
Details
Keywords
Flávio Arrais, Nuno Lopes and Paulo Vila Real
Steel beams composed of cold-formed sections are common in buildings because of their lightness and ability to support large spans. However, the instability phenomena associated…
Abstract
Purpose
Steel beams composed of cold-formed sections are common in buildings because of their lightness and ability to support large spans. However, the instability phenomena associated to these members are not completely understood in fire situation. Thus, the purpose of this study is to analyse the behaviour of beams composed of cold-formed lipped channel sections at elevated temperatures.
Design/methodology/approach
A numerical analysis is made, applying the finite element program SAFIR, on the behaviour of simply supported cold formed steel beams at elevated temperatures. A parametric study, considering several cross-sections with different slenderness’s values, steel grades and bending diagrams, is presented. The obtained numerical results are compared with the design bending resistances determined from Eurocode 3 Part 1-2 and its French National Annex (FN Annex).
Findings
The current design expressions revealed to be too conservative when compared with the obtained numerical results. It was possible to observe that the FN Annex is less conservative than the Annex E, the first having a better agreement with the numerical results.
Originality/value
Following the previous comparisons, new fire design formulae are tested. This new methodology, which introduces minimum changes in the existing formulae, provides safety and accuracy at the same time when compared to the numerical results, considering the occurrence of local, distortional and lateral torsional buckling phenomena in these members at elevated temperatures.
Details
Keywords
Qingfeng Xu, Hèrm Hofmeyer and Johan Maljaars
Simulations exist for the prediction of the behaviour of building structural systems under fire, including two-way coupled fire-structure interaction. However, these simulations…
Abstract
Purpose
Simulations exist for the prediction of the behaviour of building structural systems under fire, including two-way coupled fire-structure interaction. However, these simulations do not include detailed models of the connections, whereas these connections may impact the overall behaviour of the structure. Therefore, this paper proposes a two-scale method to include screw connections.
Design/methodology/approach
The two-scale method consists of (a) a global-scale model that models the overall structural system and (b) a small-scale model to describe a screw connection. Components in the global-scale model are connected by a spring element instead of a modelled screw, and the stiffness of this spring element is predicted by the small-scale model, updated at each load step. For computational efficiency, the small-scale model uses a proprietary technique to model the behaviour of the threads, verified by simulations that model the complete thread geometry, and validated by existing pull-out experiments. For four screw failure modes, load-deformation behaviour and failure predictions of the two-scale method are verified by a detailed system model. Additionally, the two-scale method is validated for a combined load case by existing experiments, and demonstrated for different temperatures. Finally, the two-scale method is illustrated as part of a two-way coupled fire-structure simulation.
Findings
It was shown that proprietary ”threaded connection interaction” can predict thread relevant failure modes, i.e. thread failure, shank tension failure, and pull-out. For bearing, shear, tension, and pull-out failure, load-deformation behaviour and failure predictions of the two-scale method correspond with the detailed system model and Eurocode predictions. Related to combined load cases, for a variety of experiments a good correlation has been found between experimental and simulation results, however, pull-out simulations were shown to be inconsistent.
Research limitations/implications
More research is needed before the two-scale method can be used under all conditions. This relates to the failure criteria for pull-out, combined load cases, and temperature loads.
Originality/value
The two-scale method bridges the existing very detailed small-scale screw models with present global-scale structural models, that in the best case only use springs. It shows to be insightful, for it contains a functional separation of scales, revealing their relationships, and it is computationally efficient as it allows for distributed computing. Furthermore, local small-scale non-convergence (e.g. a screw failing) can be handled without convergence problems in the global-scale structural model.
Details
Keywords
Thac Quang Nguyen, Xuan Tung Nguyen, Tri N. M. Nguyen, Thanh Bui-Tien and Jong Sup Park
The strength and stiffness of steel deteriorate rapidly at elevated temperatures. Thus, the characteristics of steel structures exposed to fire have been concerned in recent…
Abstract
Purpose
The strength and stiffness of steel deteriorate rapidly at elevated temperatures. Thus, the characteristics of steel structures exposed to fire have been concerned in recent years. Most studies on the fire response of steel structures were conducted at uniformly distributed temperatures. This study aims to evaluate the buckling capacity of steel H-beams subjected to different loading conditions under non-uniform heating.
Design/methodology/approach
A numerical investigation was conducted employing finite element analysis software, ABAQUS. A comparison between the numerical analysis results and the experimental data from previous studies was conducted to verify the beam model. Simply supported beams were loaded with several loading conditions including one end moment, end equal moments, uniformly distributed load and concentrated load at midspan. The effects of initial imperfections were considered. The buckling capacities of steel beams under fire using the existing fire design code and the previous study were also generated and compared.
Findings
The results showed that the length-to-height ratio and loading conditions have a great effect on the buckling resistance of steel beams under fire. The capacity of steel beams under non-uniform temperature distribution using the existing fire design code and the previous study can give unconservative values or too conservative values depending on loading conditions. The maximum differences of unconservative and conservative values are −44.5 and 129.2% for beams subjected to end equal moments and one end moment, respectively.
Originality/value
This study provides the buckling characteristics of steel beams under non-uniform temperature considering the influences of initial imperfections, length-to-height ratios, and loading conditions. This study will be beneficial for structural engineers in properly evaluating structures under non-uniform heating conditions.
Details
Keywords
Md Azlin Md Said, Fatimah De’nan, Nor Salwani Hashim, Bong Wely and Chuah Hoi Ching
The purpose of this study is to further investigate the potential benefits brought about by the development of modern technology in the steel construction industry. Specifically…
Abstract
Purpose
The purpose of this study is to further investigate the potential benefits brought about by the development of modern technology in the steel construction industry. Specifically, the study focuses on the optimization of tapered members for pre-engineered steel structures, aligning with Eurocode 3 standards. By emphasizing the effectiveness of material utilization in construction, this research aims to enhance the structural performance and safety of buildings. Moreover, it recognizes the pivotal role played by such advancements in promoting economic growth through the reduction of material waste, optimization of cost-efficiency and support for sustainable construction practices.
Design/methodology/approach
Structural performance at initial analysis and final analysis of the selected critical frame were carried out using Dlubal RSTAB 8.18. The structural frame stability and sway imperfections were checked based on MS EN1993-1-1:2005 (EC3). To assess the structural stability of the portal frame using MS EN 1993-1-1:2005 (EC3), cross-sectional resistance and member buckling resistance were verified based on Clause 6.2.4 – Compression, Clause 6.2.5 – Bending Moment, Clause 6.2.6 – Shear, Clause 6.2.8 – Bending and Shear, Clause 6.2.9 – Bending and Axial Force and Clause 6.3.4 – General Method for Lateral and Lateral Torsional Buckling of Structural Components.
Findings
In this study, the cross sections of the web-tapered rafter and column were classified under Class 4. These involved the consideration of elastic shear resistance and effective area on the critical steel sections. The application of the General Method on the verification of the resistance to lateral and lateral torsional buckling for structural components required the extraction of some parameters using structural analysis software. From the results, there was only 5.90% of mass difference compared with the previous case study.
Originality/value
By classifying the web-tapered cross sections of the rafter and column under Class 4, the study accounts for important factors such as elastic shear resistance and effective area on critical steel sections.
Details
Keywords
Mohamed A. Shaheen, Lee S. Cunningham and Andrew S.J. Foster
The effect of bolt stripping failure on the ductility of steel end plate beam-column connections has received relatively little investigation to date. The objective with the…
Abstract
Purpose
The effect of bolt stripping failure on the ductility of steel end plate beam-column connections has received relatively little investigation to date. The objective with the present work is to establish a validated numerical model of end plate connections at elevated temperatures, which predicts the mechanical behaviour and failure modes observed in the experimental tests including the bolt stripping failure. Furthermore, the validated FE model was used to investigate the effect of stripping failure on both the rotational and load-bearing capacity of end plate connection.
Design/methodology/approach
The analysis was conducted on a validated numerical model of end plate connections at elevated temperatures, which predicts the mechanical behaviour and failure modes observed in the experimental tests including the bolt stripping failure. The material was modelled considering ductile damage initiation and evolution featured in ABAQUS/Standard.
Findings
This study demonstrates that thick end plates can prevent stripping failure which significantly improves the rotational capacity of the connection. This failure mode can develop readily with thin end plates; however the effect is often unrealistically mitigated through idealised experimental tests. The rotational capacity of a connection can be 5.0 times higher if stripping failure is avoided, particularly at elevated temperatures. Eurocode 3 part 1.8 does not consider the possibility of stripping failure when discussing the requirements for plastic analysis. It is concluded in the present study that by allowing for the possibility of bolt stripping, the mode of failure can often shift from end plate failure to bolt stripping, this in turn significantly reduces the connection rotational capacity.
Originality/value
The effect of bolt stripping failure on the ductility of steel end plate beam-column connections has received relatively little investigation to date.
Details
Keywords
Flávio Arrais, Nuno Lopes and Paulo Vila Real
Sigma cross-section profiles are often chosen for their lightness and ability to support large spans, offering a favourable bending resistance. However, they are more susceptible…
Abstract
Purpose
Sigma cross-section profiles are often chosen for their lightness and ability to support large spans, offering a favourable bending resistance. However, they are more susceptible to local, distortional and lateral-torsional buckling, as possible failure modes when compared to common I-sections and hollow cross-sections. However, the instability phenomena associated to these members are not completely understood in fire situation. Therefore, the purpose of this study is to analyse the behaviour of beams composed of cold-formed sigma sections at elevated temperatures.
Design/methodology/approach
This study presents a numerical analysis, using advanced methods by applying the finite element software SAFIR. A numerical analysis of the behaviour of simply supported cold-formed sigma beams in the case of fire is presented considering different cross-section slenderness values, elevated temperatures, steel grades and bending moment diagrams. Comparisons are made between the obtained numerically ultimate bending capacities and the design bending resistances from Eurocode 3 Part 1–2 rules and its respective French National Annex (FN Annex).
Findings
The current design expressions revealed to be over conservative when compared with the obtained numerical results. It was possible to observe that the FN Annex is less conservative than the general prescriptions, the first having a better agreement with the numerical results.
Originality/value
Following the previous comparisons, new fire design formulae are analysed. This new methodology, which introduces minimum changes in the existing formulae, provides at the same time safety and accuracy when compared to the numerical results, considering the occurrence of local, distortional and lateral-torsional buckling phenomena in these members at elevated temperatures.
Details
Keywords
Anthony Deloge Ariyanayagam and Mahen Mahendran
This paper aims to present the details of a study undertaken to develop an energy-based time equivalent approach to obtain the fire resistance ratings (FRRs) of light gauge steel…
Abstract
Purpose
This paper aims to present the details of a study undertaken to develop an energy-based time equivalent approach to obtain the fire resistance ratings (FRRs) of light gauge steel frame (LSF) walls exposed to realistic design fire curves.
Design/methodology/approach
The energy-based time equivalent method was developed based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of the standard fire time – temperature curve. The FRR predicted by the energy-based method for LSF wall configurations exposed to both rapid and prolonged fires were compared with those from fire design rules and finite element analyses (FEA).
Findings
The proposed energy method can be used to obtain the FRR of LSF walls in case of prolonged fires and cannot be used for rapid fires as the computed FRRs were higher than the results from FEA and fire design rules due to the influence of thermal bowing and its magnification effects at a high temperature gradient across the studs for rapid fires.
Originality/value
The energy-based time equivalent method was developed based on equal fire severity principles. Three different wall configurations were considered and exposed to both rapid and prolonged fires. The FRR obtained from the energy-based method were compared with fire design rules and FEA results to assess the use of the energy-based method to predict the FRR of LSF walls.
Details
Keywords
Fridtjof Holst Øyasæter, Ashish Aeran and Sudath C. Siriwardane
Several experimental and numerical studies were performed in the past to estimate buckling capacity of corroded tubular members. However, the effect of initial imperfections has…
Abstract
Purpose
Several experimental and numerical studies were performed in the past to estimate buckling capacity of corroded tubular members. However, the effect of initial imperfections has not been properly considered in most of these earlier proposed formulas. Therefore, the main objective of this paper is to propose an accurate analytical formula to determine the buckling capacity of patched corroded tubular members.
Design/methodology/approach
Tubular members with initial geometrical imperfections can be regarded as beam-columns because of the combination of axial load and bending moment. The proposed formula is derived for a rectangular corrosion patch. The proposed formula is verified with results from finite element analysis of corroded tubular members and experimental results. The formula is also applied to an existing offshore jacket structure to highlight its significance and applicability. It is found that the buckling capacity of jacket members in splash zone reduces significantly with ageing. This reduction is around 29 and 14% for the selected brace and leg member respectively, during the design life. Finally, it is concluded that corrosion reduces the buckling capacity significantly and the proposed formula can be easily applied by practicing engineers to give an accurate and slightly conservative estimate the remaining buckling capacity.
Findings
The main finding is the new formula which accurately and conservatively estimate the buckling capacity of corroded tubular members. The proposed formula considers the secondary effect of both initial geometrical imperfections and shifting of centroid because of corrosion.
Originality/value
The proposed new formula is unique and original in that it considers both secondary effects from geometrical imperfections, reduction of cross-section from corrosion wastage and shifting of centroid because of corrosion. Finally, it is concluded that corrosion reduces the buckling capacity significantly and the proposed formula can be easily applied by practicing engineers to conservatively estimate the remaining buckling capacity and verify if further, more advanced estimations are needed.
Details