Search results

1 – 10 of over 4000
Article
Publication date: 15 February 2024

D.S.N. Senarathna, K.G.A.S. Waidyasekara and S.S.C.G. Vidana

The Heating, Ventilation and Air Conditioning (HVAC) system is a significant energy consumer in built environments, and the building energy consumption could be minimised by…

Abstract

Purpose

The Heating, Ventilation and Air Conditioning (HVAC) system is a significant energy consumer in built environments, and the building energy consumption could be minimised by optimising HVAC controls. Hence, this paper aims to investigate the applicability of Variable Refrigerant Flow (VRF) air conditioning systems for optimising the indoor comfort of buildings in Sri Lanka.

Design/methodology/approach

To address the research aim, the quantitative approach following the survey research strategy was deployed. Data collected through questionnaires were analysed using descriptive statistical tools, including Mean Rating (MR), Relative Important Index (RII) and Standard Deviation (SD).

Findings

The findings revealed that VRF systems are popularly used in Sri Lankan apartment buildings. Furthermore, energy efficiency and comfort were recognised as the most significant top-ranked benefits, while ventilation issues and initial cost were recognised as significant challenges. Moreover, the allocation of trained technicians and provision of proper ventilation through a Dedicated Outdoor Air System (DOAS) were highlighted as applicable mitigation strategies for the identified challenges in VRFs.

Practical implications

The study recommends VRF systems as a suitable technology to ensure energy efficiency, reduce GHG emissions and achieve climate performance within the built environment. The opportunities for adopting VRF systems for developing countries could be explored based on the research findings. The identified challenges would assist the design engineers and facilities professionals to devise suitable strategies to mitigate issues of VRF systems in developing countries.

Originality/value

This research provides empirical proof of the energy efficiency and comfort aspects of VRFs. The study has explored and recommended VRF technology as a beneficial application to overcome the persistent energy crisis in developing countries.

Details

Property Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0263-7472

Keywords

Article
Publication date: 24 April 2024

Haider Jouma, Muhamad Mansor, Muhamad Safwan Abd Rahman, Yong Jia Ying and Hazlie Mokhlis

This study aims to investigate the daily performance of the proposed microgrid (MG) that comprises photovoltaic, wind turbines and is connected to the main grid. The load demand…

Abstract

Purpose

This study aims to investigate the daily performance of the proposed microgrid (MG) that comprises photovoltaic, wind turbines and is connected to the main grid. The load demand is a residential area that includes 20 houses.

Design/methodology/approach

The daily operational strategy of the proposed MG allows to vend and procure utterly between the main grid and MG. The smart metre of every consumer provides the supplier with the daily consumption pattern which is amended by demand side management (DSM). The daily operational cost (DOC) CO2 emission and other measures are utilized to evaluate the system performance. A grey wolf optimizer was employed to minimize DOC including the cost of procuring energy from the main grid, the emission cost and the revenue of sold energy to the main grid.

Findings

The obtained results of winter and summer days revealed that DSM significantly improved the system performance from the economic and environmental perspectives. With DSM, DOC on winter day was −26.93 ($/kWh) and on summer day, DOC was 10.59 ($/kWh). While without considering DSM, DOC on winter day was −25.42 ($/kWh) and on summer day DOC was 14.95 ($/kWh).

Originality/value

As opposed to previous research that predominantly addressed the long-term operation, the value of the proposed research is to investigate the short-term operation (24-hour) of MG that copes with vital contingencies associated with selling and procuring energy with the main grid considering the environmental cost. Outstandingly, the proposed research engaged the consumers by smart meters to apply demand-sideDSM, while the previous studies largely focused on supply side management.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 16 May 2022

Gökçe Tomrukçu and Touraj Ashrafian

The residential buildings sector has a high priority in the climate change adaptation process due to significant CO2 emissions, high energy consumption and negative environmental…

356

Abstract

Purpose

The residential buildings sector has a high priority in the climate change adaptation process due to significant CO2 emissions, high energy consumption and negative environmental impacts. The article investigates how, conversely speaking, the residential buildings will be affected by climate change, and how to improve existing structures and support long-term decisions.

Design/methodology/approach

The climate dataset was created using the scenarios determined by the Intergovernmental Panel on Climate Change (IPCC), and this was used in the study. Different building envelope and Heating, Ventilating and Air Conditioning (HVAC) systems scenarios have been developed and simulated. Then, the best scenario was determined with comparative results, and recommendations were developed.

Findings

The findings reveal that future temperature-increase will significantly impact buildings' cooling and heating energy use. As the outdoor air temperatures increase due to climate change, the heating loads of the buildings decrease, and the cooling loads increase significantly. While the heating energy consumption of the house was calculated at 170.85 kWh/m2 in 2020, this value shall decrease significantly to 115.01 kWh/m2 in 2080. On the other hand, the cooling energy doubled between 2020 and 2080 and reached 106.95 kWh/m2 from 53.14 kWh/m2 measured in 2020.

Originality/value

Single-family houses constitute a significant proportion of the building stock. An in-depth analysis of such a building type is necessary to cope with the devastating consequences of climate change. The study developed and scrutinised energy performance improvement scenarios to define the climate change adaptation process' impact and proper procedure. The study is trying to create a strategy to increase the climate resistance capabilities of buildings and fill the gaps in this regard.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 16 June 2023

Haider Jouma Touma, Muhamad Mansor, Muhamad Safwan Abd Rahman, Yong Jia Ying and Hazlie Mokhlis

This study aims to investigate the feasibility of proposed microgrid (MG) that comprises photovoltaic, wind turbines, battery energy storage and diesel generator to supply a…

57

Abstract

Purpose

This study aims to investigate the feasibility of proposed microgrid (MG) that comprises photovoltaic, wind turbines, battery energy storage and diesel generator to supply a residential building in Grindelwald which is chosen as the test location.

Design/methodology/approach

Three operational configurations were used to run the proposed MG. In the first configuration, the electric energy can be vended and procured utterly between the main-grid and MG. In the second configuration, the energy trade was performed within 15 kWh as the maximum allowable limit of energy to purchase and sell. In the third configuration, the system performance in the stand-alone operation mode was investigated. A whale optimization technique is used to determine the optimal size of MG in all proposed configurations. The cost of energy (COE) and other measures are used to evaluate the system performance.

Findings

The obtained results revealed that the first configuration is the most beneficial with COE of 0.253$/KWh and reliable 100%. Furthermore, the whale optimization algorithm is sufficiently feasible as compared to other techniques to apply in the applications of MG.

Originality/value

The value of the proposed research is to investigate to what extend the integration between MG and main-grid is beneficial economically and technically. As opposed to previous research studies that have focused predominantly only on the optimal size of MG.

Details

International Journal of Energy Sector Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1750-6220

Keywords

Article
Publication date: 6 June 2022

Abdullahi Mohammed Usman and Kamil Abdullah

The purpose of this study is to develop a set of parameters universally acceptable for assessing design and construction strategies for reducing operational energy usage and its…

Abstract

Purpose

The purpose of this study is to develop a set of parameters universally acceptable for assessing design and construction strategies for reducing operational energy usage and its associated greenhouse gas (GHG) emission. Also, the parameters are intended to estimate the quantity of energy and its associated GHG emission reduction over the assessment period.

Design/methodology/approach

This study used five steps framework comprising definition of purpose, selecting the candidate parameters, criteria selection and description, selecting proposed parameters and defining the proposed parameters. The criteria used were the parameter’s prevalence, measurability, preference and feasibility toward adaptability to the relevant stakeholders.

Findings

This study consolidated 11 parameters. Seven cover designs and construction strategies comprising energy monitoring, natural lighting and ventilation design. Others are building thermal performance, efficient equipments, renewable energy and energy policy. The remaining four consider operational energy consumption, GHG emission quantification and their reduction over time.

Practical implications

Providing suitable indicators for assessing direct and indirect GHG emission with easily accessible data is essential for assessing built environment. The consolidated parameters can be used in developing rating systems, monitoring GHG inventories and activities of building related industries.

Originality/value

This study was conducted at the CEIES UTHM and used 11 existing rating systems open for research purposes, International Panel for Climate Change reports and GHG protocol report and guides and several other standards.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 10 May 2023

Flavio Celis-D’Amico, Ernesto Echeverria-Valiente, Rodrigo Garcia-Alvarado, Olavo Escorcia-Oyola and Fernando da Casa-Martín

This study aims to introduce the results of a research carried out to develop a prototype of a highly energy-efficient modular detached house, called CASA+ CASA means HOUSE in…

Abstract

Purpose

This study aims to introduce the results of a research carried out to develop a prototype of a highly energy-efficient modular detached house, called CASA+ CASA means HOUSE in spanish, adapted to the climatic features of central-southern Chile. The project enables a sustainable alternative to facilitate the reconstruction of the residential areas after the impact of the 2010 earthquake.

Design/methodology/approach

The methodology is based on an “integrated design process” of a case study that proposes a constructive response that quantitatively and qualitatively improves the initial data of traditional dwellings. The characteristics of the new system have been simulated with specific software to validate the final decisions, considering the cost–benefit ratio.

Findings

Simulation tools were used to assess and improve the system’s energy performance with respect to present options and to analyse its economic and construction viability. We obtained several economically competitive housing prototypes that substantially reduced energy consumption and the CO2 footprint by between 20% and 80%.

Research limitations/implications

The prototype has not been developed, as we are waiting for funding, but all its energy features have been simulated.

Practical implications

Furthermore, this experience also identified similar modifications made to the design of the houses, which revealed general possibilities for improving energy performance.

Social implications

The origin of this research is a public call for international researchers to improve the quality of the new homes to be built in Chile after the strong earthquake of 2010. The result of the research has been put at the direct service of Chilean society and in other international projects for the construction of low-energy social housing.

Originality/value

These are the result of a long research aimed at establishing a new architectural model that, in addition to improving the architectural quality of the product, obtains significant improvements in energy consumption and CO2 emissions. The most particular aspect is the practical vocation and its implementation with real construction with the support of construction companies.

Details

Construction Innovation , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 1 April 2024

Armin Saadatian and Svetlana Olbina

The retail sector has the largest energy consumption among commercial buildings in the U.S. Although previous studies explored benefits, barriers and solutions for implementing…

Abstract

Purpose

The retail sector has the largest energy consumption among commercial buildings in the U.S. Although previous studies explored benefits, barriers and solutions for implementing sustainability in various building sectors, research focused on retail facilities has been very scarce. This study aims to explore U.S. facilities managers’ perceptions of barriers that prevented the implementation of energy-efficiency practices in the retail sector. Their perceptions were compared by facility size and facilities management company’s business revenue.

Design/methodology/approach

An online survey was distributed to the members of the International Facility Management Association and the author's LinkedIn network. The survey responses were analyzed using descriptive statistical analysis and ANOVA.

Findings

Managers from large facilities, as opposed to those from small ones, significantly more agreed that the unavailability of building automation systems, a lack of professional writing skills and a lack of awareness of life cycle cost (LCC) were the barriers. Business revenue did not cause significantly different perceptions of the barriers except for a lack of awareness of LCC and a lack of support from upper management.

Originality/value

This study fills the research gap on energy efficiency in the retail sector by revealing U.S. facilities managers’ perceptions of the barriers to the implementation of energy-efficiency practices in retail stores. This novel study compares perceptions of the facilities managers by facility size and business revenue; this comparison has not been performed before. The study also identified several new barriers to the implementation of energy efficiency in the retail sector.

Details

Facilities , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0263-2772

Keywords

Article
Publication date: 22 August 2023

Xian Yun Tan, Norhayati Mahyuddin, Syahrul Nizam Kamaruzzaman, Norhayati Mat Wajid and Abdul Murad Zainal Abidin

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in…

Abstract

Purpose

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in the number of buildings is a positive sign of the rapid development of Malaysia. However, most Malaysian government office buildings tend to consume energy inefficiently due to lack of energy optimization. Most of the previous studies focused on the performance of green buildings in fulfilling the green development guidelines. As such, it is essential to study the energy performance of existing government office buildings that were constructed before most energy-efficient standards were implemented to mitigate energy wastage due to the lack of energy optimization. This study aims to analyse the energy performance of existing non-green Malaysian government office buildings and the factors that influence building energy consumption, as well as to evaluate the efficacy of the existing energy conservation measures.

Design/methodology/approach

This study was conducted by a literature review and case study. The chosen buildings are six government office building blocks located in Kuala Lumpur, the capital city of Malaysia. In this study, a literature review has been conducted on the common factors affecting energy consumption in office buildings. The energy consumption data of the buildings were collected to calculate the building energy intensity (BEI). The BEI was compared to the MS1525:2019 and GBI benchmarks to evaluate energy performance. SketchUp software was utilized to illustrate the solar radiation and sun path diagram of the case study buildings. Finally, recommendations were derived for retrofit strategies based on non-design factors and passive design factors.

Findings

In typical government office buildings, the air-conditioning system consumed the most energy at 65.5%, followed by lighting system at 22.6%, and the remaining 11.9% was contributed by office appliances. The energy performance of the case study buildings is considered as satisfactory as the BEI did not exceed the MS1525:2019 benchmark of 200 kWh/m2/year. The E Block recorded the highest BEI of 183.12 kWh/m2/year in 2020 due to its north-east orientation which is exposed to the most solar radiation. Besides, E Block consists of rooms that can accommodate large number of occupants. As such, non-design factors which include higher occupancy rate and higher cooling demand due to high outdoor temperature leads to higher energy consumption. By considering passive design features such as building orientation and building envelope thermal properties, energy consumption can be reduced significantly.

Originality/value

This study provided a comprehensive insight into the energy performance of Malaysian government office buildings, which were constructed before the energy-efficient standards being introduced. By calculating the BEI of six government office buildings, it is found that the energy performance of the case study buildings fulfils the MS1525 benchmark, and that all their BEIs are below 200 kWh/m2/year. Malaysia's hot and humid climate significantly affects a building's cooling load, and it is found the air-conditioning system is the major energy consumer of Malaysian government office buildings. This study discusses the efficacy of the energy-saving measures implemented in the case study buildings to optimize energy consumption. Recommendations were derived based on the non-design factors and passive design factors that affected the energy consumption of the case study building. It is envisioned that this study can provide practical strategies for retrofit interventions to reduce energy consumption in Malaysian office buildings as well as for office buildings that are in a similar climate.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 3 March 2022

Mahdiyeh Zaferanchi and Hatice Sozer

The amount of energy consumption of buildings has obtained international concern so the concept of zero energy building becomes a target for building designers. There are various…

Abstract

Purpose

The amount of energy consumption of buildings has obtained international concern so the concept of zero energy building becomes a target for building designers. There are various definitions and evaluation methods for efficient buildings. However, detailed research about the critical parameters that have a major effect through the operational time to reduce the energy consumption is not emphasized as this paper represents. The main aim of this study is to identify the effect of applicable interventions on energy consumption parameters with their sensitivity to each other to reach zero energy building. Relatedly, the cost of energy reduction is also determined.

Design/methodology/approach

Energy consumption parameters were defined as area lightings, space heating, space cooling, ventilation fans, pumps, auxiliary equipment and related miscellaneous equipment. The effect of each applied intervention on energy consumption was classified as high, medium, low, very low, no effect and negative effect by utilizing a sensitivity analysis. The base case's energy model is created by utilizing energy performance software such as e-Quest. Accordingly, energy performance improvement scenarios are developed by applying interventions such as lamp replacements, sensors, heat pumps and photovoltaic panels’ integration. Furthermore, sensitivity analyses of each intervention were developed for consumed energy and its cost.

Findings

Results indicated the electric consumption is more effective than gas consumption on primary energy and energy cost. Solar systems decline primary energy by 78.53%, lighting systems by 13.47% and heat pump by 5.48% in this building; therefore, integrating mentioned strategies could rise the improvement rate to 100%, in other words, zero amount of energy is using from the grid that means saving $ 5,750.39 in one year.

Research limitations/implications

The study can be applied to similar buildings. It is worthwhile to investigate suggested methods in diverse buildings with different functions and climates in future works.

Practical implications

This study aims to investigate of energy consumption of an educational building in the Mediterranean climate to convert an existing building into a zero energy building by saving energy and renewable sources. Subsequent purposes are analyzing the effect of each strategy on energy consumption and cost.

Originality/value

The novelty of this study is filling gaps in sensitivity analysis of energy consumption parameters by not only identifying their effect on overall energy consumption but also identifying their effect on each other. Some interventions may have a positive effect on overall consumption while having a negative effect on each other. Identifying this critical effect in detail not only further improves the energy performance, but also may affect the decision-making of the interventions.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 30 March 2023

Flora Bougiatioti, Eleni Alexandrou and Miltiadis Katsaros

Residential buildings in Greece constitute an important portion of the existing building stock. Furthermore, most of these buildings were built prior to the first Thermal…

Abstract

Purpose

Residential buildings in Greece constitute an important portion of the existing building stock. Furthermore, most of these buildings were built prior to the first Thermal Insulation Code of 1981. The article focuses on existing, typical residences built after 1920, which are found mostly in suburban areas and settlements all around Greece. The purpose of the research is to evaluate the effect of simple bioclimatic interventions focused on the improvement of their diurnal, inter-seasonal and annual thermal performance.

Design/methodology/approach

The applied strategies include application of thermal insulation in the building shell and openings, passive solar systems for the heating period and shading and natural ventilation for the summer period. The effect of the strategies is analysed with the use of building energy analysis. The simulation method was selected because it provides the possibility of parametric analysis and comparisons for different proposals in different orientations.

Findings

The results show that the increased thermal mass of the construction is the most decisive parameter of the thermal behaviour throughout the year.

Research limitations/implications

The typical residences under investigation are often found in urban and/or suburban surroundings. These mostly refer to free-standing buildings situated, which, in many cases, do not have the disadvantages and limitations that the geometrical characteristics of densely built urban locations impose on incident solar radiation (e.g. overshadowing during the winter) and air circulation (e.g. reduce natural ventilation during the summer). Nevertheless, even in these cases, the surrounding built environment may also have relevant negative effects, which were not taken under consideration and could be included in further, future research that will include the effect of various orientations, as well as of neighbouring buildings.

Practical implications

Existing residences built prior to the first Thermal Insulation Code (1981) form an important part of the building stock. Consequently their energy upgrade could contribute to significant conventional energy savings for heating and cooling, along with the inter-seasonal improvement of interior thermal comfort conditions.

Social implications

The proposed interventions can improve thermal comfort conditions and lead to a reduction of energy consumption for heating and cooling, which is an important step against energy poverty and the on-going energy crisis.

Originality/value

The proposed interventions only involve the building envelope and are simple with relatively low cost.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

1 – 10 of over 4000