Search results
1 – 10 of 196Tao Lin, Yaning Li, Rongjin Zhao, Zekun Ma and Jianan Xie
This paper aims to improve the device performance from the perspective of reducing ohmic contact resistance; the effects of different electrode structures and alloying parameters…
Abstract
Purpose
This paper aims to improve the device performance from the perspective of reducing ohmic contact resistance; the effects of different electrode structures and alloying parameters on the series resistance and power-current-voltage of laser diodes (LDs) have been investigated in this paper.
Design/methodology/approach
Four groups of p-GaAs side metal electrodes with different metal layer arrangements and thicknesses are fabricated for the investigated LDs. The investigated p-GaAs side electrodes are based on Ti/Pt/Au material and the n-GaAs side metal electrodes all have a same structure of Ni/Ge/Ni/Au/Ti/Pt/Au. The LDs with different electrodes were alloyed at 380°C for 60 s and 420°C for 80 s.
Findings
The experimental results show that the series resistance decreases by 14%–20%, the output power increases by 2%–2.2% and the conversion efficiency increases by 1.69%–2.16% for the LDs prepared with optimized alloying parameters (420°C for 80 s). The laser diode with p-GaAs side Ti/Pt/Au electrode of 30/70/100 nm has the best device characteristics under both annealing conditions.
Originality/value
The utilization of this improvement on ohmic contact property in electrode is not only very important for upgrading high-power LDs but also helpful for GaAs-based microelectronic devices such as HBT and monolithic microwave integrated circuit.
Details
Keywords
Jinwei Zhao, Shuolei Feng, Xiaodong Cao and Haopei Zheng
This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and…
Abstract
Purpose
This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and systems developed specifically for monitoring health and fitness metrics.
Design/methodology/approach
In recent decades, wearable sensors for monitoring vital signals in sports and health have advanced greatly. Vital signals include electrocardiogram, electroencephalogram, electromyography, inertial data, body motions, cardiac rate and bodily fluids like blood and sweating, making them a good choice for sensing devices.
Findings
This report reviewed reputable journal articles on wearable sensors for vital signal monitoring, focusing on multimode and integrated multi-dimensional capabilities like structure, accuracy and nature of the devices, which may offer a more versatile and comprehensive solution.
Originality/value
The paper provides essential information on the present obstacles and challenges in this domain and provide a glimpse into the future directions of wearable sensors for the detection of these crucial signals. Importantly, it is evident that the integration of modern fabricating techniques, stretchable electronic devices, the Internet of Things and the application of artificial intelligence algorithms has significantly improved the capacity to efficiently monitor and leverage these signals for human health monitoring, including disease prediction.
Zhen Li, Jianqing Han, Mingrui Zhao, Yongbo Zhang, Yanzhe Wang, Cong Zhang and Lin Chang
This study aims to design and validate a theoretical model for capacitive imaging (CI) sensors that incorporates the interelectrode shielding and surrounding shielding electrodes…
Abstract
Purpose
This study aims to design and validate a theoretical model for capacitive imaging (CI) sensors that incorporates the interelectrode shielding and surrounding shielding electrodes. Through experimental verification, the effectiveness of the theoretical model in evaluating CI sensors equipped with shielding electrodes has been demonstrated.
Design/methodology/approach
The study begins by incorporating the interelectrode shielding and surrounding shielding electrodes of CI sensors into the theoretical model. A method for deriving the semianalytical model is proposed, using the renormalization group method and physical model. Based on random geometric parameters of CI sensors, capacitance values are calculated using both simulation models and theoretical models. Three different types of CI sensors with varying geometric parameters are designed and manufactured for experimental testing.
Findings
The study’s results indicate that the errors of the semianalytical model for the CI sensor are predominantly below 5%, with all errors falling below 10%. This suggests that the semianalytical model, derived using the renormalization group method, effectively evaluates CI sensors equipped with shielding electrodes. The experimental results demonstrate the efficacy of the theoretical model in accurately predicting the capacitance values of the CI sensors.
Originality/value
The theoretical model of CI sensors is described by incorporating the interelectrode shielding and surrounding shielding electrodes into the model. This comprehensive approach allows for a more accurate evaluation of the detecting capability of CI sensors, as well as optimization of their performance.
Details
Keywords
Xingxing Li, Shixi You, Zengchang Fan, Guangjun Li and Li Fu
This review provides an overview of recent advances in electrochemical sensors for analyte detection in saliva, highlighting their potential applications in diagnostics and health…
Abstract
Purpose
This review provides an overview of recent advances in electrochemical sensors for analyte detection in saliva, highlighting their potential applications in diagnostics and health care. The purpose of this paper is to summarize the current state of the field, identify challenges and limitations and discuss future prospects for the development of saliva-based electrochemical sensors.
Design/methodology/approach
The paper reviews relevant literature and research articles to examine the latest developments in electrochemical sensing technologies for saliva analysis. It explores the use of various electrode materials, including carbon nanomaterial, metal nanoparticles and conducting polymers, as well as the integration of microfluidics, lab-on-a-chip (LOC) devices and wearable/implantable technologies. The design and fabrication methodologies used in these sensors are discussed, along with sample preparation techniques and biorecognition elements for enhancing sensor performance.
Findings
Electrochemical sensors for salivary analyte detection have demonstrated excellent potential for noninvasive, rapid and cost-effective diagnostics. Recent advancements have resulted in improved sensor selectivity, stability, sensitivity and compatibility with complex saliva samples. Integration with microfluidics and LOC technologies has shown promise in enhancing sensor efficiency and accuracy. In addition, wearable and implantable sensors enable continuous, real-time monitoring of salivary analytes, opening new avenues for personalized health care and disease management.
Originality/value
This review presents an up-to-date overview of electrochemical sensors for analyte detection in saliva, offering insights into their design, fabrication and performance. It highlights the originality and value of integrating electrochemical sensing with microfluidics, wearable/implantable technologies and point-of-care testing platforms. The review also identifies challenges and limitations, such as interference from other saliva components and the need for improved stability and reproducibility. Future prospects include the development of novel microfluidic devices, advanced materials and user-friendly diagnostic devices to unlock the full potential of saliva-based electrochemical sensing in clinical practice.
Details
Keywords
Wen Pin Gooi, Pei Ling Leow, Jaysuman Pusppanathan, Xian Feng Hor and Shahrulnizahani Mohammad Din
As one of the tomographic imaging techniques, electrical capacitance tomography (ECT) is widely used in many industrial applications. While most ECT sensors have electrodes placed…
Abstract
Purpose
As one of the tomographic imaging techniques, electrical capacitance tomography (ECT) is widely used in many industrial applications. While most ECT sensors have electrodes placed around a cylindrical chamber, the planar ECT sensor has been investigated for depth and defect detection. However, the planar ECT sensor has limited height and depth sensing capability due to its single-sided assessment with the use of only a single-plane design. The purpose of this paper is to investigate a dual-plane miniature planar 3D ECT sensor design using the 3 × 3 matrix electrode array.
Design/methodology/approach
The sensitivity map of dual-plane miniature planar 3D ECT sensor was analysed using 3D visualisation, the singular value decomposition and the axial resolution analysis. Then, the sensor was fabricated for performance analysis based on 3D imaging experiments.
Findings
The sensitivity map analysis showed that the dual-plane miniature planar 3D ECT sensor has enhanced the height sensing capability, and it is less ill-posed in 3D image reconstruction. The dual-plane miniature planar 3D ECT sensor showed a 28% improvement in reconstructed 3D image quality as compared to the single-plane sensor set-up.
Originality/value
The 3 × 3 matrix electrode array has been proposed to use only the necessary electrode pair combinations for image reconstruction. Besides, the increase in number of electrodes from the dual-plane sensor setup improved the height reconstruction of the test sample.
Details
Keywords
Yanyan Shi, Fenglan Huang, Meng Wang and Yongheng Li
To solve the problem of low sensitivity of traditional capacitive proximity sensor, this paper aims to propose a novel capacitive sensor for detection of an approaching conductor.
Abstract
Purpose
To solve the problem of low sensitivity of traditional capacitive proximity sensor, this paper aims to propose a novel capacitive sensor for detection of an approaching conductor.
Design/methodology/approach
Five capacitive proximity sensors with different structures are designed and the performance is compared with the traditional capacitive sensor. The impacts of geometrical parameters on the performance of the proposed capacitive sensor are studied. Furthermore, the sensitivity of the proposed capacitive sensor to an approaching conductor with different sizes is discussed. Also, how the designed capacitive sensor is sensitive to the lateral placement of the approaching object is analyzed.
Findings
Several capacitive proximity sensor structures have been designed and analyzed. It is found that the capacitive sensor with the top small ring-bottom large ring structure shows stronger electric field distribution around the top electrode and higher sensitivity to the approaching conductor than other sensors. Through further analysis of the proposed sensor, the results demonstrate that proposed capacitive sensor is effective for proximity object detection.
Originality/value
This paper proposes a novel capacitive proximity sensor with top small ring-bottom large ring structure. Compared with the traditional capacitive sensor, the proposed capacitive sensor is more sensitive to the approaching object. This would be helpful for the accurate detection of the approaching object. Also, the top and bottom electrodes are much smaller.
Details
Keywords
Xiaoping Lin, Xiaoyan Li, Jiming Yao, Xianghong Li and Jianlin Xu
To develop electrode materials for supercapacitor with superior electrochemical performance and simple preparation process, the purpose of this study is to prepare flexible…
Abstract
Purpose
To develop electrode materials for supercapacitor with superior electrochemical performance and simple preparation process, the purpose of this study is to prepare flexible CC/NiS/a-NiS electrodes with self-supporting structure by loading hydrothermally synthesized a-NiS particles along with nano-NiS on carbon cloth by electroplating method.
Design/methodology/approach
The effects of current densities, temperatures and pH values on the loading amount and uniformity of the active substances during the plating process were investigated on the basis of optimization of surface morphology, crystalline structure and electrochemical evaluation as the cyclic voltammetry curves, constant current charge–discharge curves and AC impedance.
Findings
The a-NiS particles on CC/NiS/a-NiS were mostly covered by the plated nano-NiS, which behaved as a bulge and provided a larger specific surface area. The CC/NiS/a-NiS electrode prepared with the optimized parameter exhibited a specific capacitance of 115.13 F/g at a current density of 1 A/g and a Coulomb efficiency of 84% at 5 A/g, which is superior to that of CC/NiS electrode prepared by electroplating at a current density of 10 mA/cm2, a temperature of 55°C and a pH of 4, demonstrating its fast charge response of the electrode and potential application in wearable electronics.
Originality/value
This study provides an integrated solution for the development of specifically structured NiS-based electrode for supercapacitor with simple process, low cost and high electrochemical charge/discharge performance, and the simple and easy-to-use method is also applicable to other electrochemically active composites.
Details
Keywords
Borja López-Alonso, Pablo Briz, Hector Sarnago, José M. Burdio and Oscar Lucia
This paper aims to study the feasibility of proposed method to focus the electroporation ablation by mean of multi-output multi-electrode system.
Abstract
Purpose
This paper aims to study the feasibility of proposed method to focus the electroporation ablation by mean of multi-output multi-electrode system.
Design/methodology/approach
The proposed method has been developed based on a previously designed electroporation system, which has the capabilities to modify the electric field distribution in real time, and to estimate the impedance distribution. Taking into consideration the features of the system and biological tissues, the problem has been addressed in three phases: modeling, control system design and simulation testing. In the first phase, a finite element analysis model has been proposed to reproduce the electric field distribution within the hepatic tissue, based on the characteristics of the electroporation system. Then, a control strategy has been proposed with the goal of ensuring complete ablation while minimizing the affected volume of healthy tissue. Finally, to check the feasibility of the proposal, several representative cases have been simulated, and the results have been compared with those obtained by a traditional system.
Findings
The proposed method achieves the proposed goal, as part of a complex electroporation system designed to improve the targeting, effectiveness and control of electroporation treatments and serve to demonstrate the feasibility of developing new electroporation systems capable of adapting to changes in the preplanning of the treatment in real-time.
Originality/value
The work presents a thorough study of control method to multi-output multi-electrode electroporation system by mean of a rigorous numerical simulation.
Details
Keywords
Yuchen Xi, Qinying Wang, Xinyu Tan, Xingshou Zhang, Lijin Dong, Yuhui Song, Liyang Liu and Dezhi Zeng
The purpose of this work is to design the wire beam electrode (WBE) of P110 steel and study its corrosion behavior and mechanism under high temperature and pressure.
Abstract
Purpose
The purpose of this work is to design the wire beam electrode (WBE) of P110 steel and study its corrosion behavior and mechanism under high temperature and pressure.
Design/methodology/approach
Packaging materials of the new type P110 steel WBE and high pressure stable WBE structure were designed. A metallurgical microscope (XJP-3C) and scanning electron microscopy (EV0 MA15 Zeiss) with an energy dispersive spectrometer were used to analyze the microstructure and composition of the P110 steel. The electrochemical workstation (CS310, CorrTest Instrument Co., Ltd) with a WBE potential and current scanner was used to analyze the corrosion mechanism of P110 steel.
Findings
According to the analysis of Nyquist plots at different temperatures, the corrosion resistance of P110 steel decreases with the increase of temperature under atmospheric pressure. In addition, Rp of P110 steel under high pressure is maintained in the range of 200 ∼ 375 Ωcm2, while that under atmospheric pressure is maintained in the range of 20 ∼ 160 Ωcm2, indicating that the corrosion products on P110 steel under high pressure is denser, which improves the corrosion resistance of P110 steel to a certain extent.
Originality/value
The WBE applied in high temperature and pressure environment is in blank. This work designed and prepared a WBE of P110 steel for high temperature and pressure environment, and the corrosion mechanism of P110 steel was revealed by using the designed WBE.
Details
Keywords
Reetu Yadav, Mamta Kushwah, Anna Nikolaevna Berlina and Mulayam Singh Gaur
The purpose of this study is determination of cadmium using silver-gold bimetallic nanoparticles (Ag-Au BMNPs) and an aptamer modified glassy carbon electrode.
Abstract
Purpose
The purpose of this study is determination of cadmium using silver-gold bimetallic nanoparticles (Ag-Au BMNPs) and an aptamer modified glassy carbon electrode.
Design/methodology/approach
The maximum response of modified electrode was obtained with, 50 mV pulse amplitude, 20 mV/s scan rate in phosphate buffer of pH 4.0. Ag-Au BMNPs, as the mediators improved electron transmit during the entire electron transfer process and the aptasensor response. Herein, the authors used aptamer as the capture probe to prepare an aptasensor with enhanced stability.
Findings
The proposed aptasensor exhibited a wide linearity to cadmium in the range of 0.001–0.100 µg/L with a low detection limit of 0.005×10−3 µg/L. The glassy carbon electrodes with Ag-Au BMNPs showed a lower detection limit.
Originality/value
This aptasensor has good reproducibility, stability and repeatability and is cost-effective to regenerate. The specificity and selectivity of the novel modified electrode is tested in the presence of other interfering metal ions such as Fe2+, Mn2+, Mg2+, Sb3+ and Bi3+. The aptasensor shows 10 times more sensitivity and selectivity for Cd2+ ions.