Search results

1 – 10 of over 1000
Article
Publication date: 18 December 2023

Hamdi Ercan, Cüneyt Öztürk and Mustafa Akın

This paper aims to assess the impact of electrifying the environmental control system (ECS) and ice protection system (IPS), the primary pneumatic system consumers in a…

Abstract

Purpose

This paper aims to assess the impact of electrifying the environmental control system (ECS) and ice protection system (IPS), the primary pneumatic system consumers in a conventional commercial transport aircraft, on aircraft weight, range, and fuel consumption.

Design/methodology/approach

The case study was carried out on Airbus A321-200 aircraft. Design, modelling and analysis processes were carried out on Pacelab SysArc software. Conventional and electrical ECS and IPS architectures were modelled and analysed considering different temperature profiles.

Findings

The simulation results have shown that the aircraft model with ±270 VDC ECS and IPS architecture is lighter, has a more extended range and has less relative fuel consumption. In addition, the simulation results showed that the maximum range and relative fuel economy of all three aircraft models increased slightly as the temperature increased.

Practical implications

Considering the findings in this paper, it is seen that the electrification of the conventional pneumatic system in aircraft has positive contributions in terms of weight, power consumption and fuel consumption.

Social implications

The positive contributions in terms of weight, power consumption and fuel consumption in aircraft will be direct environmental and economic contributions.

Originality/value

Apart from the conventional ECS and IPS of the aircraft, two electrical architectures, 230 VAC and ±270 VDC, were modelled and analysed. To see the effects of the three models created in different temperature profiles, analyses were done for cold day, ISA standard day and hot day temperature profiles.

Details

Aircraft Engineering and Aerospace Technology, vol. 96 no. 2
Type: Research Article
ISSN: 1748-8842

Keywords

Article
Publication date: 3 April 2024

Erol Can and Ugur Kilic

Static inverters are very important for the emergency energy distribution system of aircraft and similar machines. At the same time, the electrical energy produced at high…

Abstract

Purpose

Static inverters are very important for the emergency energy distribution system of aircraft and similar machines. At the same time, the electrical energy produced at high frequency for electrical devices is used to reduce the weight of the cables in the aircraft and spacecraft because of the skin effect. In the high-frequency system, a thinner cable cross-section is used, and a great weight reduction occurs in the aircraft. So, fuel economy, less and late wear of the materials (landing gear, etc.) can be obtained with decreasing weight. This paper aims to present the development of a functional multilevel inverter (FMLI) with fractional sinus pulse width modulation (FSPWM) and a reduced number of switches to provide high-frequency and quality electrical energy conversion.

Design/methodology/approach

After the production of FSPWM for FMLI with a reduced component, which, to the best of the authors’ knowledge, is presented for the first time in this study, is explained step by step, and eight operating states are given according to different FSPWMs operating the circuit. The designed inverter and modulation technique are compared by testing the conventional modular multilevel inverter on different loads.

Findings

According to application results, it is seen that there is a 50% reduction in cross-section from 100 Hz to 400 Hz with the skin effect. At 1000 Hz, there is a 90% cross-section reduction. The decrease can be in cable weights that may occur in aircraft from 10 kg to 100 kg according to different frequencies. It causes less harmonic distortion than conventional converters. This supports the safer operation of the system. Compared to the traditional system, the proposed system provides more amplitude in converting the source to alternating voltage and increases the efficiency.

Practical implications

FSPWM is developed for multilevel inverters with reduced components at the high frequency and cascaded switching studies in the power electronics of aircraft.

Social implications

Although the proposed system has less current and power loss as mentioned in the previous sections, it contains fewer power elements than conventional inverters that are equivalent for different hardware levels. This not only reduces the cost of the system but also provides ease of maintenance. To reduce the cable load in aircraft and create more efficient working conditions, 400 Hz alternative voltage is used. The proposed system causes less losses and lower harmonic distortions than traditional systems. This will reduce possible malfunctions and contribute to aircraft reliability for passengers and cargo. As technology develops, it is revealed that the proposed inverter system will be more efficient than traditional inverters when devices operating at frequencies higher than 400 Hz are used. With the proposed inverter, safer operation will be ensured, while there will be less energy loss, less fuel consumption and less carbon emissions to the environment.

Originality/value

The proposed inverter structure shows that it can provide energy transmission for electrical devices in space and aircraft by using the skin effect. It also contains less power elements than the traditional inverters, which are equivalent for different levels of hardware.

Details

Aircraft Engineering and Aerospace Technology, vol. 96 no. 3
Type: Research Article
ISSN: 1748-8842

Keywords

Article
Publication date: 12 March 2024

Dhobale Yash and R. Rajesh

The study aims to identify the possible risk factors for electricity grids operational disruptions and to determine the most critical and influential risk indicators.

33

Abstract

Purpose

The study aims to identify the possible risk factors for electricity grids operational disruptions and to determine the most critical and influential risk indicators.

Design/methodology/approach

A multi-criteria decision-making best-worst method (BWM) is employed to quantitatively identify the most critical risk factors. The grey causal modeling (GCM) technique is employed to identify the causal and consequence factors and to effectively quantify them. The data used in this study consisted of two types – quantitative periodical data of critical factors taken from their respective government departments (e.g. Indian Meteorological Department, The Central Water Commission etc.) and the expert responses collected from professionals working in the Indian electric power sector.

Findings

The results of analysis for a case application in the Indian context shows that temperature dominates as the critical risk factor for electrical power grids, followed by humidity and crop production.

Research limitations/implications

The study helps to understand the contribution of factors in electricity grids operational disruptions. Considering the cause consequences from the GCM causal analysis, rainfall, temperature and dam water levels are identified as the causal factors, while the crop production, stock prices, commodity prices are classified as the consequence factors. In practice, these causal factors can be controlled to reduce the overall effects.

Practical implications

From the results of the analysis, managers can use these outputs and compare the risk factors in electrical power grids for prioritization and subsequent considerations. It can assist the managers in efficient allocation of funds and manpower for building safeguards and creating risk management protocols based on the severity of the critical factor.

Originality/value

The research comprehensively analyses the risk factors of electrical power grids in India. Moreover, the study apprehends the cause-consequence pair of factors, which are having the maximum effect. Previous studies have been focused on identification of risk factors and preliminary analysis of their criticality using autoregression. This research paper takes it forward by using decision-making methods and causal analysis of the risk factors with blend of quantitative and expert response based data analysis to focus on the determination of the criticality of the risk factors for the Indian electric power grid.

Details

Benchmarking: An International Journal, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1463-5771

Keywords

Article
Publication date: 12 April 2022

Jingbo Zhao, Yan Tao and Zhiming Sun

This paper aims to clarify voltage sourced converter’s (VSC’s) influence rules on the alternating current (AC) short-circuit current and identify the key factors, so as to propose…

131

Abstract

Purpose

This paper aims to clarify voltage sourced converter’s (VSC’s) influence rules on the alternating current (AC) short-circuit current and identify the key factors, so as to propose the short-circuit current suppression strategy.

Design/methodology/approach

This paper investigates the key factors which impact the short-circuit current supplied by the VSC based on the equivalent current source model. This study shows that the phase of the VSC equivalent current source is mainly affected by the type of fault, whereas the amplitude is mainly decided by the control mode, the amplitude limiter and the electrical distance. Based on the above influence mechanism, the dynamic limiter with short-circuit current limiting function is designed. The theoretical analysis is verified by simulations on PSCAD.

Findings

The short-circuit current feeding from VSC is closely related to the control mode and control parameters of the VSC, fault type at AC side and the electrical distance of the fault point. The proposed dynamic limiter can make VSC absorb more reactive power to suppress the short-circuit current.

Research limitations/implications

The dynamic limiter proposed in this paper is limited to suppress three-phase short-circuit fault current. The future work will focus more on improving and extending the dynamic limiter to the fault current suppression application in other fault scenarios.

Practical implications

The research results provide a reference for the design of protection system.

Originality/value

The key influence factors are conducive to put forward the measures to suppress the fault current, eliminate the risk of short-circuit current exceeding the standard and reduce the difficulty of protection design.

Details

Circuit World, vol. 49 no. 4
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 19 December 2022

Mohammad Fathi, Roya Amjadifard, Farshad Eshghi and Manoochehr Kelarestaghi

Photovoltaic (PV) systems are experiencing exponential growth due to environmental concerns, unlimited and ubiquitous solar energy, and starting-to-make-sense panel costs…

Abstract

Purpose

Photovoltaic (PV) systems are experiencing exponential growth due to environmental concerns, unlimited and ubiquitous solar energy, and starting-to-make-sense panel costs. Alongside designing more efficient solar panels, installing solar trackers and special circuitry for optimizing power delivery to the load according to a maximum power point tracking (MPPT) algorithm are other ways of increasing efficiency. However, it is critical for any efficiency increase to account for the power consumption of any amendments. Therefore, this paper aims to propose a novel tracker while using MPPT to boost the PV system's actual efficiency accounting for the involved costs.

Design/methodology/approach

The proposition is an experimental pneumatic dual-axis solar tracker using light-dependent resistor (LDR) sensors. Due to its embedded energy storage, the pneumatic tracker offers a low duty-cycle operation leading to tracking energy conservation, fewer maintenance needs and scalability potential. While MPPT assures maximum load power delivery, the solar PV's actual delivered power is calculated for the first time, accounting for the solar tracking and MPPT power costs.

Findings

The experiments' results show an increase of 37.6% in total and 35.3% in actual power production for the proposed solar tracking system compared to the fixed panel system, with an MPPT efficiency of 90%. Thus, the pneumatic tracking system offers low tracking-energy consumption and good actual power efficiency. Also, the newly proposed pneumatic stimulant can significantly simplify the tracking mechanism and benefit from several advantages that come along with it.

Originality/value

To the best of the authors’ knowledge, this work proposes, for the first time, a single-motor pneumatic dual-axis tracker with less implementation cost, less frequent operation switching and scalability potential, to be developed in future works. Also, the pneumatic proposal delivers high actual power efficiency for the first time to be addressed.

Details

World Journal of Engineering, vol. 21 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Open Access
Article
Publication date: 28 February 2023

Mohammed Jawad Abed and Anis Mhalla

The paper aims to present a grid-connected multi-inverter for solar photovoltaic (PV) systems to enhance reliability indices after selected the placement and level of PV solar.

Abstract

Purpose

The paper aims to present a grid-connected multi-inverter for solar photovoltaic (PV) systems to enhance reliability indices after selected the placement and level of PV solar.

Design/methodology/approach

In this study, the associated probability is calculated based on the solar power generation capacity levels and outages conditions. Then, based on this probability, dependability indices like average energy not supplied (AENS), expected energy not supplied and loss of load expectations (LOLE) are computed, also, another indices have been computed such as (customer average interruption duration index (CAIDI), system average interruption frequency index (SAIFI) and system average interruption duration index (SAIDI)) addressing by affected customers with distribution networks reliability assessment, including PV. On the basis of their dependability indices and active power flow, several PV solar modules installed in several places are analyzed. A mechanism for assessing the performance of the grid's integration of renewable energy sources is also under investigation.

Findings

The findings of this study based on data extracted form a PV power plant connected to the power network system in Diyala, Iraq 132 kV, attempts to identify the system's weakest points in order to improve the system's overall dependability. In addition, enhanced reliability indices are given for measuring solar PV systems performance connected to the grid and reviewed for the benefit of the customers.

Originality/value

The main contributions of this study are two methods for determining the reliability of PV generators taking into consideration the system component failure rates and the power electronic component defect rates in a PV system which depend on the power input and the power loss using electrical transient analysis program (ETAP) program.

Details

Arab Gulf Journal of Scientific Research, vol. 42 no. 1
Type: Research Article
ISSN: 1985-9899

Keywords

Article
Publication date: 7 April 2023

Pedro Bento, Sílvio Mariano, Pedro Carvalho, Maria do Rosário Calado and José Pombo

This study is a targeted review of some of the major changes in European regulation that guided energy policy decisions in the Iberian Peninsula and how they may have aggravated…

Abstract

Purpose

This study is a targeted review of some of the major changes in European regulation that guided energy policy decisions in the Iberian Peninsula and how they may have aggravated the problem of lack of flexibility. This study aims to assess some of the proposed short-term solutions to address this issue considering the underlying root causes and suggests a different course of action, that in turn, could help alleviate future market strains.

Design/methodology/approach

The evolution of the most important (macro) energy and price-related variables in both Portugal and Spain is assessed using market and grid operator data. In addition, the authors present critical viewpoints on some of the most recent EU and national regulation changes (official document analysis).

Findings

The Iberian energy policy and regulatory agenda has successfully promoted a rapid adoption of renewables (main goal), although with insufficient diversification of generation technologies. The compulsory closings of thermal plants and an increased tax (mainly carbon) added pressure toward more environmentally friendly thermal power plants. However, inevitably, this curbed the bidding price competitiveness of these producers in an already challenging market framework. Moving forward, decisions must be based on “a bigger picture” that does not neglect system flexibility and security of supply and understands the specificities of the Iberian market and its generation portfolio.

Originality/value

This work provides an original account of unprecedented spikes in energy prices in 2021, specifically in the Iberian electricity market. This acute situation worries consumers, industry and governments. Underlining the instability of the market prices, for the first time, this study discusses how some of the most important regulatory changes, and their perception and absorption by involved parties, contributed to the current environment. In addition, this study stresses that if flexibility is overlooked, the overall purpose of having an affordable and reliable system is at risk.

Details

International Journal of Energy Sector Management, vol. 18 no. 2
Type: Research Article
ISSN: 1750-6220

Keywords

Article
Publication date: 6 February 2023

Eric Zanghi, Milton Brown Do Coutto Filho and Julio Cesar Stacchini de Souza

The current and modern electrical distribution networks, named smart grids (SGs), use advanced technologies to accomplish all the technical and nontechnical challenges naturally…

Abstract

Purpose

The current and modern electrical distribution networks, named smart grids (SGs), use advanced technologies to accomplish all the technical and nontechnical challenges naturally demanded by energy applications. Energy metering collecting is one of these challenges ranging from the most basic (i.e., visual assessment) to the expensive advanced metering infrastructure (AMI) using intelligent meters networks. The AMIs’ data acquisition and system monitoring environment require enhancing some routine tasks. This paper aims to propose a methodology that uses a distributed and sustainable approach to manage wide-range metering networks, focused on using current public or private telecommunication infrastructure, optimizing the implementation and operation, increasing reliability and decreasing costs.

Design/methodology/approach

Inspired by blockchain technology, a collaborative metering system architecture is conceived, managing massive data sets collected from the grid. The use of cryptography handles data integrity and security issues.

Findings

A robust proof-of-concept simulation results are presented concerning the resilience and performance of the proposed distributed remote metering system.

Originality/value

The methodology proposed in this work is an innovative AMI solution related to SGs. Regardless of the implementation, operation and maintenance of AMIs, the proposed solution is unique, using legacy and new technologies together in a reliable way.

Details

International Journal of Innovation Science, vol. 16 no. 2
Type: Research Article
ISSN: 1757-2223

Keywords

Article
Publication date: 1 June 2022

Sagarika Rout and Gyan Ranjan Biswal

Notable energy losses and voltage deviation issues in low-voltage radial distribution systems are a major concern for power planners and utility companies because of the…

Abstract

Purpose

Notable energy losses and voltage deviation issues in low-voltage radial distribution systems are a major concern for power planners and utility companies because of the integration of electric vehicles (EVs). Electric vehicle charging stations (EVCSs) are the key components in the network where the EVs are equipped to energize their battery. The purpose of this paper is coordinating the EVCS and distributed generation (DG) so as to place them optimally using swarm-based elephant herding optimization techniques by considering energy losses, voltage sensitivity and branch current as key indices. The placement and sizing of the EVCS and DG were found in steps.

Design/methodology/approach

The IEEE 33-bus test feeder and 52-bus Indian practical radial networks were used as the test system for the network characteristic analysis. To enhance the system performance, the radial network is divided into zones for the placement of charging stations and dispersed generation units. Balanced coordination is discussed with three defined situations for the EVCS and DG.

Findings

The proposed analysis shows that DG collaboration with EVCS with suitable size and location in the network improves the performance in terms of stability and losses.

Research limitations/implications

Stability and loss indices are handled with equal weight factor to find the best solution.

Social implications

The proposed method is coordinating EVCS and DG in the existing system; the EV integration in the low-voltage side can be incorporated suitably. So, it has societal impact.

Originality/value

In this study, the proposed method shows improved results in terms EVCS and DG integration in the system with minimum losses and voltage sensitivity. The results have been compared with another population-based particle swarm optimization method (PSO). There is an improvement of 18% in terms of total power losses and 9% better result in minimum node voltage as compared to the PSO technique. Also, there is an enhancement of 33% in the defined voltage stability index which shows the proficiency of the proposed analysis.

Details

World Journal of Engineering, vol. 20 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 19 May 2022

Merlin Sajini M.L., Suja S. and Merlin Gilbert Raj S.

The purpose of the study is distributed generation planning in a radial delivery framework to identify an appropriate location with a suitable rating of DG units energized by…

Abstract

Purpose

The purpose of the study is distributed generation planning in a radial delivery framework to identify an appropriate location with a suitable rating of DG units energized by renewable energy resources to scale back the power loss and to recover the voltage levels. Though several algorithms have already been proposed through the target of power loss reduction and voltage stability enhancement, further optimization of the objectives is improved by using a combination of heuristic algorithms like DE and particle swarm optimization (PSO).

Design/methodology/approach

The identification of the candidate buses for the location of DG units and optimal rating of DG units is found by a combined differential evolution (DE) and PSO algorithm. In the combined strategy of DE and PSO, the key merits of both algorithms are combined. The DE algorithm prevents the individuals from getting trapped into the local optimum, thereby providing efficient global optimization. At the same time, PSO provides a fast convergence rate by providing the best particle among the entire iteration to obtain the best fitness value.

Findings

The proposed DE-PSO takes advantage of the global optimization of DE and the convergence rate of PSO. The different case studies of multiple DG types are carried out for the suggested procedure for the 33- and 69-bus radial delivery frameworks and a real 16-bus distribution substation in Tamil Nadu to show the effectiveness of the proposed methodology and distribution system performance. From the obtained results, there is a substantial decrease in the power loss and an improvement of voltage levels across all the buses of the system, thereby maintaining the distribution system within the framework of system operation and safety constraints.

Originality/value

A comparison of an equivalent system with the DE, PSO algorithm when used separately and other algorithms available in literature shows that the proposed method results in an improved performance in terms of the convergence rate and objective function values. Finally, an economic benefit analysis is performed if a photo-voltaic based DG unit is allocated in the considered test systems.

1 – 10 of over 1000