Xiaoyuan Wang, Yongqing Guo, Chen Chen, Yuanyuan Xia and Yaqi Liu

This study aims to analyze the differences of electrocardiograph (ECG) characteristics for female drivers in calm and anxious states during driving.

Abstract

Purpose

This study aims to analyze the differences of electrocardiograph (ECG) characteristics for female drivers in calm and anxious states during driving.

Design/methodology/approach

The authors used various materials (e.g. visual materials, auditory materials and olfactory materials) to induce drivers’ mood states (calm and anxious), and then conducted the real driving experiments and driving simulations to collect driver’s ECG signal dynamic data. Physiological changes in ECG during the stimulus process were recorded using PSYLAB software. The paired T-test analysis was conducted to determine if there is a significant difference in driver’s ECG characteristics between calm and anxious states during driving.

Findings

The results show significant differences in the characteristic parameters of female driver’s ECG signals, including (average heart rate), (atrioventricular interval), (percentage of NN intervals > 50ms), (R wave average peak), (Root mean square of successive), (Q wave average peak) and ( S wave average peak), in time domain, frequency domain and waveform in emotional states of calmness and anxiety.

Practical implications

Findings of this work show that ECG can be used to identify driver’s anxious and calm states during driving. It can be used for the development of personalized driver assistance system and driver warning system.

Originality/value

Only a few attempts have been made on the influence of human emotions on physiological signals in the transportation field. Hence, there is a need for transport scholars to begin to identify driver’s ECG characteristics under different emotional states. This study will analyze the differences of ECG characteristics for female drivers in calm and anxious states during driving to provide a theoretical basis for developing the intelligent and connected vehicles.

Details

Journal of Intelligent and Connected Vehicles, vol. 2 no. 2
Type: Research Article
ISSN: 2399-9802

Keywords

Article
Publication date: 28 April 2020

Gennadiy Evtushenko, Inna A. Lezhnina, Artem I. Morenetz, Boris N. Pavlenko, Arman A. Boyakhchyan, Stanislav N. Torgaev and Irina Nam

The purpose of this paper is the development and study of capacitive coupling electrodes with the ability to monitor the quality of the skin–electrode contact in the process of…

Abstract

Purpose

The purpose of this paper is the development and study of capacitive coupling electrodes with the ability to monitor the quality of the skin–electrode contact in the process of electrocardiogram (ECG) diagnostics. The study’s scope embraces experimental identification of distortions contributed into the recorded ECG signal at various degrees of disturbance of the skin–electrode contact.

Design/methodology/approach

A capacitive coupling electrode is designed and manufactured. A large number of experiments was carried out to record ECG signals with different quality of the skin–electrode contact. Using spectral analysis, the characteristic distortions of the ECG signals in the event of contact disturbance are revealed.

Findings

It was found that the violation of the skin–electrode contact leads to significant deterioration in the recorded signal. In this case, the most severe distortions appear with various violations of the skin–electrode contact of two sensors in one lead. It has been experimentally shown that the developed sensor allows monitoring the quality of the contact, and therefore, improvement of the quality of signal registration, enabled by the use of bespoke processing algorithms.

Practical implications

These sensors will be used in personalized medicine devices and tele-ECG devices.

Originality/value

In this work, authors studied the effect of the skin–electrode contact of a capacitive electrode with the body on the quality of the recorded ECG signal. Based on the studies, the necessity of monitoring contact was shown to improve the quality of diagnostics provided by personalized medicine devices; the capacitive sensor with contact feedback was developed.

Details

Sensor Review, vol. 40 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 24 September 2021

Qiang Wang, Chen Meng and Cheng Wang

This study aims to reveal the essential characteristics of nonstationary signals and explore the high-concentration representation in the joint time–frequency (TF) plane.

Abstract

Purpose

This study aims to reveal the essential characteristics of nonstationary signals and explore the high-concentration representation in the joint time–frequency (TF) plane.

Design/methodology/approach

In this paper, the authors consider the effective TF analysis for nonstationary signals consisting of multiple components.

Findings

To make it, the authors propose the combined multi-window Gabor transform (CMGT) under the scheme of multi-window Gabor transform by introducing the combination operator. The authors establish the completeness utilizing the discrete piecewise Zak transform and provide the perfect-reconstruction conditions with respect to combined TF coefficients. The high-concentration is achieved by optimization. The authors establish the optimization function with considerations of TF concentration and computational complexity. Based on Bergman formulation, the iteration process is further analyzed to obtain the optimal solution.

Originality/value

With numerical experiments, it is verified that the proposed CMGT performs better in TF analysis for multi-component nonstationary signals.

Details

Engineering Computations, vol. 39 no. 4
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 16 April 2024

Jinwei Zhao, Shuolei Feng, Xiaodong Cao and Haopei Zheng

This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and…

Abstract

Purpose

This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and systems developed specifically for monitoring health and fitness metrics.

Design/methodology/approach

In recent decades, wearable sensors for monitoring vital signals in sports and health have advanced greatly. Vital signals include electrocardiogram, electroencephalogram, electromyography, inertial data, body motions, cardiac rate and bodily fluids like blood and sweating, making them a good choice for sensing devices.

Findings

This report reviewed reputable journal articles on wearable sensors for vital signal monitoring, focusing on multimode and integrated multi-dimensional capabilities like structure, accuracy and nature of the devices, which may offer a more versatile and comprehensive solution.

Originality/value

The paper provides essential information on the present obstacles and challenges in this domain and provide a glimpse into the future directions of wearable sensors for the detection of these crucial signals. Importantly, it is evident that the integration of modern fabricating techniques, stretchable electronic devices, the Internet of Things and the application of artificial intelligence algorithms has significantly improved the capacity to efficiently monitor and leverage these signals for human health monitoring, including disease prediction.

Details

Sensor Review, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 14 January 2014

Zhelong Wang, Cong Zhao and Sen Qiu

– The purpose of this paper is to develop a health monitoring system that can measure human vital signs and recognize human activity based on body sensor network (BSN).

Abstract

Purpose

The purpose of this paper is to develop a health monitoring system that can measure human vital signs and recognize human activity based on body sensor network (BSN).

Design/methodology/approach

The system is mainly composed of electrocardiogram (ECG) signal collection node, blood oxygen signal collection node, inertial sensor node, receiving node and upper computer software. The three collection nodes collect ECG signals, blood oxygen signals and motion signals. And then collected signals are transmitted wirelessly to receiving node and analyzed by software in upper computer in real-time.

Findings

Experiment results show that the system can simultaneously monitor human ECG, heart rate, pulse rate, SpO2 and recognize human activity. A classifier based on coupled hidden Markov model (CHMM) is adopted to recognize human activity. The average recognition accuracy of CHMM classifier is 94.8 percent, which is higher than some existent methods, such as supported vector machine (SVM), C4.5 decision tree and naive Bayes classifier (NBC).

Practical implications

The monitoring system may be used for falling detection, elderly care, postoperative care, rehabilitation training, sports training and other fields in the future.

Originality/value

First, the system can measure human vital signs (ECG, blood pressure, pulse rate, SpO2, temperature, heart rate) and recognizes some specific simple or complex activities (sitting, lying, go boating, bicycle riding). Second, the researches of using CHMM for activity recognition based on BSN are extremely few. Consequently, the classifier based on CHMM is adopted to recognize activity with ideal recognition accuracies in this paper.

Details

Sensor Review, vol. 34 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 22 April 2022

Sreedhar Jyothi and Geetanjali Nelloru

Patients having ventricular arrhythmias and atrial fibrillation, that are early markers of stroke and sudden cardiac death, as well as benign subjects are all studied using the…

Abstract

Purpose

Patients having ventricular arrhythmias and atrial fibrillation, that are early markers of stroke and sudden cardiac death, as well as benign subjects are all studied using the electrocardiogram (ECG). In order to identify cardiac anomalies, ECG signals analyse the heart's electrical activity and show output in the form of waveforms. Patients with these disorders must be identified as soon as possible. ECG signals can be difficult, time-consuming and subject to inter-observer variability when inspected manually.

Design/methodology/approach

There are various forms of arrhythmias that are difficult to distinguish in complicated non-linear ECG data. It may be beneficial to use computer-aided decision support systems (CAD). It is possible to classify arrhythmias in a rapid, accurate, repeatable and objective manner using the CAD, which use machine learning algorithms to identify the tiny changes in cardiac rhythms. Cardiac infractions can be classified and detected using this method. The authors want to categorize the arrhythmia with better accurate findings in even less computational time as the primary objective. Using signal and axis characteristics and their association n-grams as features, this paper makes a significant addition to the field. Using a benchmark dataset as input to multi-label multi-fold cross-validation, an experimental investigation was conducted.

Findings

This dataset was used as input for cross-validation on contemporary models and the resulting cross-validation metrics have been weighed against the performance metrics of other contemporary models. There have been few false alarms with the suggested model's high sensitivity and specificity.

Originality/value

The results of cross validation are significant. In terms of specificity, sensitivity, and decision accuracy, the proposed model outperforms other contemporary models.

Details

International Journal of Intelligent Unmanned Systems, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2049-6427

Keywords

Article
Publication date: 16 August 2022

Anil Kumar Gona and Subramoniam M.

Biometric scans using fingerprints are widely used for security purposes. Eventually, for authentication purposes, fingerprint scans are not very reliable because they can be…

Abstract

Purpose

Biometric scans using fingerprints are widely used for security purposes. Eventually, for authentication purposes, fingerprint scans are not very reliable because they can be faked by obtaining a sample of the fingerprint of the person. There are a few spoof detection techniques available to reduce the incidence of spoofing of the biometric system. Among them, the most commonly used is the binary classification technique that detects real or fake fingerprints based on the fingerprint samples provided during training. However, this technique fails when it is provided with samples formed using other spoofing techniques that are different from the spoofing techniques covered in the training samples. This paper aims to improve the liveness detection accuracy by fusing electrocardiogram (ECG) and fingerprint.

Design/methodology/approach

In this paper, to avoid this limitation, an efficient liveness detection algorithm is developed using the fusion of ECG signals captured from the fingertips and fingerprint data in Internet of Things (IoT) environment. The ECG signal will ensure the detection of real fingerprint samples from fake ones.

Findings

Single model fingerprint methods have some disadvantages, such as noisy data and position of the fingerprint. To overcome this, fusion of both ECG and fingerprint is done so that the combined data improves the detection accuracy.

Originality/value

System security is improved in this approach, and the fingerprint recognition rate is also improved. IoT-based approach is used in this work to reduce the computation burden of data processing systems.

Details

International Journal of Pervasive Computing and Communications, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1742-7371

Keywords

Article
Publication date: 29 July 2021

Aarathi S. and Vasundra S.

Pervasive analytics act as a prominent role in computer-aided prediction of non-communicating diseases. In the early stage, arrhythmia diagnosis detection helps prevent the cause…

Abstract

Purpose

Pervasive analytics act as a prominent role in computer-aided prediction of non-communicating diseases. In the early stage, arrhythmia diagnosis detection helps prevent the cause of death suddenly owing to heart failure or heart stroke. The arrhythmia scope can be identified by electrocardiogram (ECG) report.

Design/methodology/approach

The ECG report has been used extensively by several clinical experts. However, diagnosis accuracy has been dependent on clinical experience. For the prediction methods of computer-aided heart disease, both accuracy and sensitivity metrics play a remarkable part. Hence, the existing research contributions have optimized the machine-learning approaches to have a great significance in computer-aided methods, which perform predictive analysis of arrhythmia detection.

Findings

In reference to this, this paper determined a regression heuristics by tridimensional optimum features of ECG reports to perform pervasive analytics for computer-aided arrhythmia prediction. The intent of these reports is arrhythmia detection. From an empirical outcome, it has been envisioned that the project model of this contribution is more optimal and added a more advantage when compared to existing or contemporary approaches.

Originality/value

In reference to this, this paper determined a regression heuristics by tridimensional optimum features of ECG reports to perform pervasive analytics for computer-aided arrhythmia prediction. The intent of these reports is arrhythmia detection. From an empirical outcome, it has been envisioned that the project model of this contribution is more optimal and added a more advantage when compared to existing or contemporary approaches.

Details

International Journal of Pervasive Computing and Communications, vol. 20 no. 1
Type: Research Article
ISSN: 1742-7371

Keywords

Article
Publication date: 3 July 2020

Ali Ghasemi, Farzin Shama, Gholamreza Karimi and Farshad Khosravi

The purpose of this paper is to provide appropriate methods for reducing the abnormalities on the extracted fetal heart signal from the maternal electrocardiogram (ECG).

Abstract

Purpose

The purpose of this paper is to provide appropriate methods for reducing the abnormalities on the extracted fetal heart signal from the maternal electrocardiogram (ECG).

Design/methodology/approach

In this regard, the extracted signal of the fetal heart from the mother, improved using an active noise cancelation (ANC) system. It uses commonly adaptive algorithms of normalized least mean squares (NLMS). In the present paper, fetal extraction and denoising methodology are proposed. This methodology uses a combination of the NLMS algorithm with Savitzky–Golay (S-G) filter.

Findings

The obtained results show that a combination of NLMS algorithm with filter coefficient of 15 and µ = 0.02 and S-G filter has a better qSNR (qSNR = 3.6727) and good performance for fetal ECG extraction in comparison with the other works for average fmSNR in the range of −30 to −15 dB. Also, with considering the SNR value of −24.7 dB before filtering and SNR = 3.1861 dB after filtering; the SNR improvement of 27.8861 dB has been obtained.

Originality/value

A new method in the extract and noise reduction of fetal ECG from maternal ECG by the combination of NLMS algorithm and S-G filter is proposed.

Details

Circuit World, vol. 47 no. 1
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 8 January 2021

Ashok Naganath Shinde, Sanjay L. Nalbalwar and Anil B. Nandgaonkar

In today’s digital world, real-time health monitoring is becoming a most important challenge in the field of medical research. Body signals such as electrocardiogram (ECG)…

Abstract

Purpose

In today’s digital world, real-time health monitoring is becoming a most important challenge in the field of medical research. Body signals such as electrocardiogram (ECG), electromyogram and electroencephalogram (EEG) are produced in human body. This continuous monitoring generates huge count of data and thus an efficient method is required to shrink the size of the obtained large data. Compressed sensing (CS) is one of the techniques used to compress the data size. This technique is most used in certain applications, where the size of data is huge or the data acquisition process is too expensive to gather data from vast count of samples at Nyquist rate. This paper aims to propose Lion Mutated Crow search Algorithm (LM-CSA), to improve the performance of the LMCSA model.

Design/methodology/approach

A new CS algorithm is exploited in this paper, where the compression process undergoes three stages: designing of stable measurement matrix, signal compression and signal reconstruction. Here, the compression process falls under certain working principle, and is as follows: signal transformation, computation of Θ and normalization. As the main contribution, the theta value evaluation is proceeded by a new “Enhanced bi-orthogonal wavelet filter.” The enhancement is given under the scaling coefficients, where they are optimally tuned for processing the compression. However, the way of tuning seems to be the great crisis, and hence this work seeks the strategy of meta-heuristic algorithms. Moreover, a new hybrid algorithm is introduced that solves the above mentioned optimization inconsistency. The proposed algorithm is named as “Lion Mutated Crow search Algorithm (LM-CSA),” which is the hybridization of crow search algorithm (CSA) and lion algorithm (LA) to enhance the performance of the LM-CSA model.

Findings

Finally, the proposed LM-CSA model is compared over the traditional models in terms of certain error measures such as mean error percentage (MEP), symmetric mean absolute percentage error (SMAPE), mean absolute scaled error, mean absolute error (MAE), root mean square error, L1-norm and L2-normand infinity-norm. For ECG analysis, under bior 3.1, LM-CSA is 56.6, 62.5 and 81.5% better than bi-orthogonal wavelet in terms of MEP, SMAPE and MAE, respectively. Under bior 3.7 for ECG analysis, LM-CSA is 0.15% better than genetic algorithm (GA), 0.10% superior to particle search optimization (PSO), 0.22% superior to firefly (FF), 0.22% superior to CSA and 0.14% superior to LA, respectively, in terms of L1-norm. Further, for EEG analysis, LM-CSA is 86.9 and 91.2% better than the traditional bi-orthogonal wavelet under bior 3.1. Under bior 3.3, LM-CSA is 91.7 and 73.12% better than the bi-orthogonal wavelet in terms of MAE and MEP, respectively. Under bior 3.5 for EEG, L1-norm of LM-CSA is 0.64% superior to GA, 0.43% superior to PSO, 0.62% superior to FF, 0.84% superior to CSA and 0.60% better than LA, respectively.

Originality/value

This paper presents a novel CS framework using LM-CSA algorithm for EEG and ECG signal compression. To the best of the authors’ knowledge, this is the first work to use LM-CSA with enhanced bi-orthogonal wavelet filter for enhancing the CS capability as well reducing the errors.