Search results

1 – 10 of 20
Article
Publication date: 23 August 2022

Shireen Mohammed Abed, Sabah M. Mohammad, Zainuriah Hassan, Aminu Muhammad and Suvindraj Rajamanickam

The purpose of this study is to fabricate an ultraviolet (UV) metal-semiconductor-metal (MSM) photodetector based on zinc oxide nanorods (ZnO NRs) grown on seeded silicon (Si…

Abstract

Purpose

The purpose of this study is to fabricate an ultraviolet (UV) metal-semiconductor-metal (MSM) photodetector based on zinc oxide nanorods (ZnO NRs) grown on seeded silicon (Si) substrate that was prepared by a low-cost method (drop-casting technique).

Design/methodology/approach

The drop-casting method was used for the seed layer deposition, the hydrothermal method was used for the growth of ZnO NRs and subsequent fabrication of UV MSM photodetector was done using the direct current sputtering technique. The performance of the fabricated MSM devices was investigated by current–voltage (I–V) measurements. The photodetection mechanism of the fabricated device was discussed.

Findings

Semi-vertically high-density ZnO (NRs) were effectively produced with a preferential orientation along the (002) direction, and increased crystallinity is confirmed by X-ray diffraction analysis. Photoluminescence results show a high UV region. The fabricated MSM UV photodetector showed that the ZnO (NRs) MSM device has great stability over time, high photocurrent, good sensitivity and high responsivity under 365 nm wavelength illumination and 0 V, 1 V, 2 V and 3 V applied bias. The responsivity and sensitivity for the fabricated ZnO NRs UV photodetector are 0.015 A W-1, 0.383 A W-1, 1.290 A W-1 and 1.982 A W-1 and 15,030, 42.639, 100.173 and 334.029, respectively, under UV light (365 nm) illumination at (0 V, 1 V, 2 V and 3 V).

Originality/value

This paper uses the drop-casting technique and the hydrothermal method as simple and low-cost methods to fabricate and improve the ZnO NRs photodetector.

Details

Microelectronics International, vol. 40 no. 1
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 12 August 2021

Amrita M., Rukmini Srikant Revuru, Sreeram Chatti, Sree Satya Bharati Sri Satya Moram, Chandu Byram and Venugopal Rao Soma

Ti6Al4V is a commonly used titanium alloy with several applications in aerospace industry due to its excellent strength to weight ratio. But due to low thermal conductivity, it is…

Abstract

Purpose

Ti6Al4V is a commonly used titanium alloy with several applications in aerospace industry due to its excellent strength to weight ratio. But due to low thermal conductivity, it is categorized as “difficult to machine.” Though machinability can be improved with cutting fluids, it is not preferred due to associated problems. This study aims at eliminating the use of cutting fluid and finding an alternate solution to dry machining of Ti6Al4V. AlTiN coated tools provide good heat and oxidation resistance but have low lubricity. In the present work, graphene, which is known for lubricating properties, is added to the tools using five different methods (tool condition) to form graphene self-lubricated cutting tools.

Design/methodology/approach

Graphene-based self-lubricating tools are prepared by using five methods: dip coating (10 dips and 30 dips); drop casting; and filling of micro/macroholes. Performance of these tools is evaluated in terms of cutting forces, surface roughness and tool wear by machining Ti6Al4V and comparing with conventional coated cutting tool.

Findings

Self-lubricating tool with micro holes filled with graphene outperformed other tools and showed maximum decrease of 33.42% in resultant cutting forces, 35% in surface roughness (Ra) and 30% in flank wear compared to conventional cutting tool.

Originality/value

Analysis of variance for all forces show that tool condition and machining time have significant influence on all components of cutting forces and resultant cutting forces.

Details

World Journal of Engineering, vol. 19 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 7 December 2022

Haowei Zhang, Lili Sun, Chengli Song, Ying Liu, Xueting Xuan, Fei Wang, Jing Zhong and Li Sun

Design, fabricate and evaluate all-solid-state wearable sensor systems that can monitor ion concentrations in human sweat to provide real time health analysis and disease…

Abstract

Purpose

Design, fabricate and evaluate all-solid-state wearable sensor systems that can monitor ion concentrations in human sweat to provide real time health analysis and disease diagnosis capabilities.

Design/methodology/approach

A human health monitoring system includes disposable customized flexible electrode array and a compact signal transmission-processing electronic unit.

Findings

Patterned rGO (reduced-graphene oxide) layers can replace traditional metal electrodes for the fabrication of free-standing all solid film sensors to provide improved flexibility, sensitivity, selectivity, and stability in ion concentration monitoring. Electrochemical measurements show the open circuit potential of current selective electrodes exhibit near Nernst responses versus Na+ and K+ ion concentration in sweat. These signals show great stability during a typical measurement period of 3 weeks. Sensor performances evaluated through real time measurements on human subjects show strong correlations between subject activity and sweating levels, confirming high degree of robustness, sensitivity, reliability and practicality of current sensor systems.

Originality/value

In improving flexibility, stability and interfacial coherency of chemical sensor arrays, rGO films have been the developed as a high-performance alternative to conventional electrode with significant cost and processing complexity reduction. rGO supported solid state electrode arrays have been found to have linear potential response versus ion concentration, suitable for electrochemical sensing applications. Current sweat sensor system has a high degree of integration, including electrode arrays, signal processing circuits, and data visualization interfaces.

Details

Sensor Review, vol. 42 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 3 January 2017

Khasan S. Karimov, Zubair Ahmad, Noshin Fatima, Muhammad Mansoor Ahmed and Muhammad Abid

The paper aims to study the effects of humidity on the electrical properties of copper phthalocyanine (CuPc) thin films deposited at different gravity conditions.

Abstract

Purpose

The paper aims to study the effects of humidity on the electrical properties of copper phthalocyanine (CuPc) thin films deposited at different gravity conditions.

Design/methodology/approach

Surface-type samples were fabricated on glass substrates with preliminary-deposited copper electrodes. The CuPc solution was prepared in benzene. The thin films of CuPc were deposited on these substrates at diverse gravity conditions by drop-casting and centrifugation at 1 × g and 70 × g, respectively. Impedance and capacitance of the fabricated devices were measured against the different relative humidity ranging from 32 to 98 per cent.

Findings

The impedance and the capacitance of the CuPc film were found to be dependent on the ambient humidity levels (32-98 per cent) and the gravity conditions (1 × g and 70 × g) opted during the fabrication process.

Research limitations/implications

The centrifugation technique can potentially be used in the instrumentation industry for the fabrication of humidity sensors.

Practical implications

The results of the investigations can potentially be used in the instrumentation and optoelectronics industry for the fabrication of humidity sensors.

Originality/value

CuPc films were deposited from a solution in benzene using drop-casting and centrifugation. The electrical properties of the films were found to be dependent on film fabrication conditions and ambient humidity levels. Growth-dependent electrical properties of the CuPc films can be explained by considering their structure.

Details

Pigment & Resin Technology, vol. 46 no. 1
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 17 June 2021

Mohammed Gamil, Nagih M. Shaalan and Ahmed Abd El-Moneim

This study aims to present an efficient and reliable graphene nanoplatelets (GNPs)-based temperature sensor.

343

Abstract

Purpose

This study aims to present an efficient and reliable graphene nanoplatelets (GNPs)-based temperature sensor.

Design/methodology/approach

A high-quality dispersion of GNPs was dropped by casting method on platinum electrodes deposited on a polyethylene terephthalate (PET) substrate. The GNPs were characterized by scanning electron microscope, Raman spectroscopy and X-ray diffraction spectra to ensure its purity and quality. The temperature sensing behavior of the fabricated sensor was examined by subjecting it to different temperatures, range from room temperature (RT) to 150 °C.

Findings

Excellent resistance linearity with temperature change was achieved. Temperature coefficient of resistance of the fabricated sensor was calculated as 1.4 × 10–3°C. The sensor also showed excellent repeatability and stability for the measured temperature range. Good response and recovery times were evaluated at all the measured temperatures. With measuring the sensor response, the ambient temperature can be determined.

Originality/value

The present work presents a new simply and low cost fabricated temperature sensor based on GNPs working at a wide temperature range.

Details

Sensor Review, vol. 41 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 11 April 2022

Hadeel Alhazimeh, Mohamed Ghazi Al-Fandi and Lina M.K. Al-Ebbini

Ascorbic acid (AA) is an essential vitamin for human health. Therefore, fast and cost-effective detecting of AA is essential, whether in human or food samples. The purpose of this…

Abstract

Purpose

Ascorbic acid (AA) is an essential vitamin for human health. Therefore, fast and cost-effective detecting of AA is essential, whether in human or food samples. The purpose of this paper is to develop an electrochemical nanosensor for AA detection.

Design/methodology/approach

The proposed nanosensor was developed by printing carbon nanoparticles ink and silver nanoparticles ink on a polydimethylsiloxane (PDMS) substrate. The surface of the PDMS substrate was first treated by corona plasma. Then, the nanomaterials printer was used to deposit both inks on the substrate. The working electrode surface was modified by drop-casting of carbon nanotubes. Morphological evaluation was applied using scanning electron microscopy and cyclic voltammetry. Also, a potentiostat was used to detect AA by differential pulse voltammetry.

Findings

It has been shown that the developed nanosensor linearly worked at a range of (0–5 mM), with a limit of detection lower than 0.8 mM and a relative standard deviation of 6.6%.

Originality/value

The developed nanosensor is characterized by a simple and cost-effective sensing tool for AA. In particular, the nanomaterials enhanced the nanosensor’s sensitivity due to the high catalytic activity.

Details

Sensor Review, vol. 42 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 5 May 2015

Kh.S. Karimov, Nisar Ahmed, M. Mehran Bashir, Fakhra Aziz, M.Zeeshan Rizvi, Adam Khan, M. Tahir, Nayyer Abbas Zaidi, Muhammad Hafeez and Arshad Saleem Bhatti

The purpose of this paper is to fabricate and investigate sensing properties of a novel, flexible resistive tensile load cells based on multi-walled carbon nano-tubes…

Abstract

Purpose

The purpose of this paper is to fabricate and investigate sensing properties of a novel, flexible resistive tensile load cells based on multi-walled carbon nano-tubes (MWCNTs)/rubber composites. The use of carbon nanotubes makes it very attractive for being used as sensors.

Design/methodology/approach

On thin rubber substrate, MWCNTs powder was deposited and pressed at elevated temperature. Two types of samples were prepared: first sample was made by depositing MWCNTs suspension in water on the substrate, then the sample was dried at room temperature; the second sample was prepared by applying dry MWCNTs powder directly on the substrate.

Findings

The resistances of the cells made from wet MWCNT powder are much lower than those made with dry powder. It was found that the fabricated load cells were highly sensitive to the force and showed good repeatability. The resistance of the flexible resistive tensile MWCNTs/rubber composite load cells increased 1.37 times, on average, with the increasing force (up to 0.045 N). The sensitivity of the cells was equal to 142 N-1.

Practical implications

The device fabrication method used here provides a simple, less expensive and effective approach for preparing resistive tensile load cells.

Originality/value

A novel, flexible resistive tensile load cells using MWCNTs/rubber composites have been successfully fabricated and investigated. MWCNTs, in dry and wet form, have been deposited on thin rubber substrates by adopting a very simple and inexpensive technique.

Details

Pigment & Resin Technology, vol. 44 no. 3
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 17 July 2018

A.G. Mohan Das Gandhi, K. Soorya Prakash and V. Kavimani

This paper aims to examine the investigations made on the corrosion behaviour of magnesium (Mg) substrate electrodeposited using different nano-materials.

Abstract

Purpose

This paper aims to examine the investigations made on the corrosion behaviour of magnesium (Mg) substrate electrodeposited using different nano-materials.

Design/methodology/approach

This study uses nano-materials such as those of reduced graphene oxide (r-GO), titanium-di-oxide (TiO2) and also r-GO/TiO2 nano-composites (dispersed through ultra-sonication process) at 3-min time interval. Crystalline nature of synthesized TiO2 is studied through X-ray diffraction and its pore volume is measured to be approximately 0.1851ccg-1 by Brunauer Emmett Teller analysis.

Findings

Surface morphology of the developed set of specimens inspected through scanning electron microscopy and energy dispersive spectroscopy establishes a clean surface coating and further witnesses for only minimal defects. Electrochemical behaviour of the developed coating is studied exhaustively using Tafel polarization and electrochemical impedance spectroscopy in 0.1 M Na2SO4 solution.

Originality/value

Incremental corrosion resistance exhibited by developed composite coating owes to the factors viz. chemical stability and hydrophobic tendency of TiO2 and r-GO; these known engineering facts resist the flow of ions into the corrosive media and thereby reduce the rate of corrosion.

Details

Anti-Corrosion Methods and Materials, vol. 65 no. 4
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 14 March 2024

Gülçin Baysal

The aim of this review is to present together the studies on textile-based moisture sensors developed using innovative technologies in recent years.

Abstract

Purpose

The aim of this review is to present together the studies on textile-based moisture sensors developed using innovative technologies in recent years.

Design/methodology/approach

The integration levels of the sensors studied with the textile materials are changing. Some research teams have used a combination of printing and textile technologies to produce sensors, while a group of researchers have used traditional technologies such as weaving and embroidery. Others have taken advantage of new technologies such as electro-spinning, polymerization and other techniques. In this way, they tried to combine the good working efficiency of the sensors and the flexibility of the textile. All these approaches are presented in this article.

Findings

The presentation of the latest technologies used to develop textile sensors together will give researchers an idea about new studies that can be done on highly sensitive and efficient textile-based moisture sensor systems.

Originality/value

In this paper humidity sensors have been explained in terms of measuring principle as capacitive and resistive. Then, studies conducted in the last 20 years on the textile-based humidity sensors have been presented in detail. This is a comprehensive review study that presents the latest developments together in this area for researchers.

Details

International Journal of Clothing Science and Technology, vol. 36 no. 2
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 16 March 2015

Munezza Ata Khan, Umar Ansari and Murtaza Najabat Ali

Real-time monitoring of wound or injured tissues is critical for speedy recovery, and the onset of a cascade of biochemical reactions provides potential biomarkers that facilitate…

Abstract

Purpose

Real-time monitoring of wound or injured tissues is critical for speedy recovery, and the onset of a cascade of biochemical reactions provides potential biomarkers that facilitate the process of wound monitoring, e.g. pH, temperature, moisture level, bacterial load, cytokines, interleukins, etc. Among all the biomarkers, pH has been known to have a profound impact on the wound healing process, and is used to determine the incidence of bacterial infection of the wound (persistently elevated alkaline pH), proteolytic activity at the site of injury, take rate in skin grafting, wound healing stage and preparation for wound debridement.

Design/methodology/approach

This review highlights the significance of pH in determination of clinical parameters and for selection of an appropriate treatment regime, and it presents an in-depth analysis of the designs and fabrication methods that use integrated pH sensors, which have been reported to date for the real-time monitoring of wound healing.

Findings

For an expedited wound healing process, the significance of pH mandated the need of an integrated sensor system that would facilitate real-time monitoring of healing wounds and obviate the requirement of redressing or complicated testing procedures, which are both labor-intensive and painful for the patient. The review also discussed different types of sensor systems which were developed using hydrogel as a pH-responsive system coupled with voltammetry, potentiometry, impedimetric and flex-circuit inductive transducer systems. All of the mentioned devices have considerable potential for clinical applications, and there is need of in vivo testing to validate their efficiency and sensitivity under practical scenarios.

Originality/value

This manuscript is an original review of literature, and permission has been granted to use the figures from previously published papers.

Details

Sensor Review, vol. 35 no. 2
Type: Research Article
ISSN: 0260-2288

Keywords

1 – 10 of 20