Search results

1 – 10 of over 2000
Article
Publication date: 1 February 1991

David Golding

This article describes the design and application of underwater cable location systems.

Abstract

This article describes the design and application of underwater cable location systems.

Details

Sensor Review, vol. 11 no. 2
Type: Research Article
ISSN: 0260-2288

Article
Publication date: 30 September 2014

Michael J. Armstrong and Christine A.H. Ross

This article is aims to inform aircraft propulsion system designers of the implications which fundamental power distribution design assumptions have on the effectiveness and…

Abstract

Purpose

This article is aims to inform aircraft propulsion system designers of the implications which fundamental power distribution design assumptions have on the effectiveness and viability of turboelectric distributed propulsion (TeDP) systems. Improvements and challenges associated with selecting alternating or direct current for normal- and superconducting distribution systems are presented. Additionally, for superconducting systems, the benefits of bi-polar DC distribution are discussed, as well as the implications of operating voltage on the mass and efficiency of TeDP grid components.

Design/methodology/approach

The approach to this paper selects several high-level fundamental configuration decisions, which must be made, and it qualitatively discusses potential implications of these decisions.

Findings

Near term TeDP architectures which employ conventionally conducting systems may benefit from alternating current (AC) distribution concepts to eliminate the mass and losses associated with power conversion. Farther term TeDP concepts which employ superconducting technologies may benefit from direct current (DC) distribution to reduce the cryocooling requirements stemming from AC conduction losses. Selecting the operating voltage for superconducting concepts requires a divergence from the present day criteria employed with terrestrial superconducting transmission systems.

Practical implications

The criteria presented in the paper will assist in the early conceptual architecting of TeDP systems.

Originality/value

The governing principles behind the configuration of multi-MW airborne electrical microgrid systems are presently immature. This paper represents a unique look and the motivating principles behind fundamental electrical configuration decisions in the context of TeDP.

Details

Aircraft Engineering and Aerospace Technology: An International Journal, vol. 86 no. 6
Type: Research Article
ISSN: 0002-2667

Keywords

Article
Publication date: 6 July 2015

Nebojsa B. Raicevic and Nikola Raicevic

Underground cables can produce higher electromagnetic fields directly above them than an overhead line. The majority of cable failures on distribution system are caused by defects…

Abstract

Purpose

Underground cables can produce higher electromagnetic fields directly above them than an overhead line. The majority of cable failures on distribution system are caused by defects in the cable accessories. Nowadays, significant research has been carried out worldwide into examining whether electricity, and in particular, the presence of electric and magnetic fields have an adverse impact on health, especially the occurrence of cancer and childhood leukemia. The purpose of this paper is to optimize the electric field distribution in underground cable accessories. This reduces the impact of the harmful effects of the fields on living beings and humans.

Design/methodology/approach

Cable terminations and joints are designed to eliminate the stress concentration at the termination screen to avoid the breakdown of the cable and high values of electric field at these points. Any improvement in the cable termination and joints construction is of great interest. There are several methods for the solution of electric field distribution. These can be summarized as analytical, experimental, free-hand field mapping, analogue methods and numerical methods. In this paper cable accessories are modeled by using multilayer dielectric system and very thin deflector’s cones.

Findings

This model includes specific insulators design and smart choice of electrodes position. Stress-grading nonlinear materials in form of tapes and tubes were used with much success. In order to optimize the cable joint parameters, two criteria were monitored – total electric field magnitude and magnitude of the tangential component. More than 30 percent is reduced impact of cables on the environment.

Originality/value

In order to investigate the accuracy of the applied numerical model, various configurations of the cable accessories are studied. The first time is applied new Hybrid Boundary Elements Method on the protection of the environment.

Details

COMPEL: The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, vol. 34 no. 4
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 8 May 2018

Miao He, Miao Hao, George Chen, Wenpeng Li, Chong Zhang, Xin Chen, Haitian Wang, Mingyu Zhou and Xianzhang Lei

For the dramatically developed high voltage direct current (HVDC) power transmission, HVDC cables play a vital role in the power transmission across seas and connections with…

Abstract

Purpose

For the dramatically developed high voltage direct current (HVDC) power transmission, HVDC cables play a vital role in the power transmission across seas and connections with renewable power sources. However, the condition monitoring of HVDC cables is still a challenging research topic. This paper aims to understand the influence of external factors, namely, current, cavity location and material properties, on partial discharge (PD) characteristics in HVDC cable in a numerical way referring to the refined Niemeyer’s model.

Design/methodology/approach

The influences of the three external factors are studied by a proposed numerical model for DC PDs based on the modification of a conventional PD model for AC voltage via a finite element analysis method.

Findings

The external factors can influence the discharge magnitude and discharge repetition rate via affecting the electrical conductivity of the material: DC PD is more frequent and with higher discharge magnitude when the cavity is closer to the conductor or the current through the conductor is higher. Both DC PD repetition rate and average discharge magnitude in long-term aged material are lower than virgin material. The effect of discharge on insulation degradation becomes decreasingly significant.

Research limitations/implications

The current work is based on the numerical modelling of DC PDs. Further experimental validations and comparisons are essential for improving the model.

Practical implications

The studies of the influence factors for PDs under HVDC voltage can benefit the research and practical power transmission on DC PDs, contributing the design and test of DC PDs in HVDC cables, exploring the understandings of the DC PDs’ mechanism.

Originality/value

This paper, to the best of author’s knowledge, first studies the influence factors on DC PDs based on the numerical modelling work.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 37 no. 3
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 1 January 2014

Jerzy Golebiowski and Robert Piotr Bycul

– The paper aims to propose a parallel algorithm in order to increase speed and efficiency of an analysis of transient thermal field in layered DC cables.

Abstract

Purpose

The paper aims to propose a parallel algorithm in order to increase speed and efficiency of an analysis of transient thermal field in layered DC cables.

Design/methodology/approach

Initial-boundary problem of thermal field was discretized by means of implicit finite difference method in cylindrical coordinates. A two-stage time decomposition method was applied to introduce parallel computations. An assumed duration of the transient state was decomposed. The system of algebraic equations was being solved with the use of a conjugate gradient method (with diagonal preconditioning) in all time intervals simultaneously.

Findings

A method for solving (with the use of parallel computing system) the transient heat conduction equation in a DC cable consisting of arbitrary number of material layers was given. The dependence of the convective heat transfer coefficient on the location on the perimeter of the cable and on its surface temperature (which introduced non-linearity in the boundary condition) was taken into account. The influence of the determined field on the efficiency of the heat source was also taken into consideration in the model.

Research limitations/implications

The main limitation is induced by cylindrical and coaxial structure of the consecutive layers of the system. Thermal field is generated by direct current flow only. The length of the fragment of the cable under consideration should be much greater than its diameter.

Practical implications

The time-spatial distribution of thermal field in the cross-section of the cable can be used for analysis of its reliability and for determination of important characteristics and parameters of the system.

Originality/value

A parallel algorithm of solving initial-boundary parabolic problem was proposed as a result of synthesis of three methods (finite difference, time decomposition and conjugate gradient). An algorithm of minimization of disturbances of the solution introduced at the division points was given. Equations approximating real distribution of heat transfer coefficient from the surface of the cable were proposed.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 24 no. 1
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 3 January 2017

Kosei Shinoda, Xavier Guillaud, Seddik Bacha, Abdelkrim Benchaib and Bruno Francois

Self-commuted voltage source converter (VSC) can significantly extend the flexibility and operability of an HVDC system and be used to implement the concept of multi-terminal HVDC…

Abstract

Purpose

Self-commuted voltage source converter (VSC) can significantly extend the flexibility and operability of an HVDC system and be used to implement the concept of multi-terminal HVDC (MTDC) grid. To take full advantage of MTDC systems, its overall behaviour must be characterized in quasi static and dynamic states. Based on the numerous literatures, a dedicated two-level VSC model and its local controllers and DC grid voltage regulators are developed for this purpose. Furthermore, the requirement of the system to guarantee all the physical constrains must be well assessed and concrete demonstrations must be provided by numerical simulations.

Design/methodology/approach

First, a two-level VSC model and its local controllers and DC grid voltage regulators are developed. Then, DC cable models are investigated and their characteristics are assessed in the frequency domain. Those developed models are combined to form a three-terminal HVDC grid system on Matlab/Simulink platform. To analyze the stability of this electrical system, the dynamics of the system against variations of power dispatch are observed.

Findings

To analyze the stability of this electrical system, the dynamics of the system against variations of power dispatch are observed. The differences in the DC grid voltage dynamics and the power flow of the converter stations coming from the embedded primary controls are analysed, and the technical requirements for both cases are assessed.

Originality/value

In this paper, the dynamic stability of an MTDC system has been analysed and assessed through an adequate simulation model, including its control scheme and the cable models. The interest of the improved PI model for cables is highlighted.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 36 no. 1
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 5 March 2018

Miao He, Miao Hao, George Chen, Xin Chen, Wenpeng Li, Chong Zhang, Haitian Wang, Mingyu Zhou and Xianzhang Lei

High voltage direct current (HVDC) cable is an important part in the electric power transmission and distribution systems. However, very little research has been carried out on…

Abstract

Purpose

High voltage direct current (HVDC) cable is an important part in the electric power transmission and distribution systems. However, very little research has been carried out on partial discharge under direct current (DC) conditions. Niemeyer’s model has been widely used under alternating current (AC) conditions. This paper aims to intend to modify the Niemeyer’s model considering both electric field and charge dynamics under DC conditions, and therefore proposes a numerical model describing partial discharge characteristics in HVDC cable.

Design/methodology/approach

This paper intends to understand partial discharge characteristics under DC conditions through numerical modelling. Niemeyer’s model that has been widely used under AC conditions has been modified, taking both electric field and charge dynamics under DC conditions into consideration. The effects of loading level or current through the conductor, cavity location and material properties on partial discharges have also been studied.

Findings

Electrical conductivity is important in determining the characteristics of partial discharge under DC conditions and discharges tend to happen in short when the cavity field exceeds the inception level under the parameter values studied in the paper.

Research limitations/implications

Building the numerical model is the purpose of the paper, and there is lack in experiment and the comparison between the simulation results and experiment.

Practical implications

The proposed model provides the numerical model describing partial discharge in HVDC cable and helps understand the partial discharge mechanism under DC voltage.

Originality/value

To the best of the author’s knowledge, this paper is a very early research on the numerical modelling work on partial discharge under DC voltage.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 37 no. 2
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 1 April 2014

Jerzy Golebiowski and Robert Piotr Bycul

The purpose of this paper is to prepare procedures for determination of characteristics and parameters of DC cables on the basis of transient and steady thermal field distribution…

Abstract

Purpose

The purpose of this paper is to prepare procedures for determination of characteristics and parameters of DC cables on the basis of transient and steady thermal field distribution in their cross-sections.

Design/methodology/approach

Steady-state current rating was computed iteratively, with the use of steady thermal field distribution in the cable. The iterative process was regulated with respect to this field by changes of the mean surface temperature of the sheath of the cable. It was also controlled with respect to the unknown current rating by deviations of the temperature of the core from the maximum sustained temperature of the insulation (material zone) adjacent to the core. Heating curves were determined (in arbitrarily selected points of the cross-section of the cable) by a parallel algorithm described thoroughly in the first part of the paper. The algorithm was used for computing of transient thermal field distribution throughout the whole cross-section. Thermal time constant distributions were determined by the trapezium rule, where the upper integration limit of respective thermal field distributions was being changed.

Findings

Using the methods prepared the following characteristics/parameters of the cable were determined: steady-state current rating, spatial-time heating curves, mean thermal time constant distribution. The results were verified and turned to be in conformance with those of the IEC 287 Standard and a commercial software – Nisa v. 16. Speedup and efficiency of the parallel computations were calculated. It was concluded that the parallel computations took less time than the sequential ones.

Research limitations/implications

The specialized algorithms and software are dedicated to cylindrical DC cables.

Practical implications

The knowledge of the determined characteristics and parameters contributes to optimal exploitation of a DC cable during its use.

Originality/value

The algorithms of determination of the steady-state current rating and thermal time constant are original. The software described in the appendix has also been made by the authors.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 24 no. 3
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 1 March 1983

Judith Sessions and Cathy Haworth

This bibliography concentrates on literature sources currently published (as in the case of periodicals) or generally published during the past three years. Annotations are…

Abstract

This bibliography concentrates on literature sources currently published (as in the case of periodicals) or generally published during the past three years. Annotations are provided for periodicals and books, noting strengths of the sources. Selected journal articles, including several pre‐1980 citations, are included without annotations.

Details

Library Hi Tech, vol. 1 no. 3
Type: Research Article
ISSN: 0737-8831

Article
Publication date: 6 March 2009

Jerzy Gołębiowski and Marek Zaręba

The purpose of this paper is to present a method of solving a thermal conduction equation in three‐zone axially‐symmetrical systems.

Abstract

Purpose

The purpose of this paper is to present a method of solving a thermal conduction equation in three‐zone axially‐symmetrical systems.

Design/methodology/approach

In the method developed, the field functions are determined in the analytical way by the superposition of states and separation of variables method. The coefficients of the field functions and eigenvalues of the boundary‐initial problem are computed by the numerical method. The coefficients are the solution to the corresponding sets of equations. These sets are the result of scalar products of non‐orthogonal functions at the respective zones of the cable. The eigenvalues are determined by an algorithm, which uses the field properties and elements of the golden cut method.

Findings

The method made it possible to develop a mathematical model of the dynamics of the thermal field in a polymer DC cable. This model has good physical interpretation. The paper also presents the field distributions determined in an analytical form. Some arguments of the expressions derived are however computed numerically. The results obtained by the paper's method and by the finite elements methods were compared. The relative differences are less than 6 per cent.

Research limitations/implications

The method concerns axially‐symmetrical three‐zone systems under nominal conditions.

Practical implications

By means of the method important parameters of DC lines can be determined (e.g. spatial‐temporal heat‐up curves, admissible sustained currents, time constants).

Originality/value

An analytical‐numerical method of analysis of the thermal field in a three‐zone axially‐symmetrical system was developed. Its original element is the algorithm of determination of eigenvalues of the boundary‐initial problem and coefficients of non‐orthogonal field functions.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 28 no. 2
Type: Research Article
ISSN: 0332-1649

Keywords

1 – 10 of over 2000