1 – 10 of over 2000As arc suppression coils (ASCs), magnetically controlled reactors (MCRs) are usually operated in the single-phase mode. Due to the lack of a third order harmonic compensation…
Abstract
Purpose
As arc suppression coils (ASCs), magnetically controlled reactors (MCRs) are usually operated in the single-phase mode. Due to the lack of a third order harmonic compensation circuit, the current harmonics are high. The purpose of this paper is to propose a novel structure of MCR and a genetic algorithm (GA) to determine the parameters which will result in minimum total harmonics.
Design/methodology/approach
This paper proposes the structure and the working principle of the multi-valve controlled saturable reactor (MCSR). There are several sorts of magnetic valves in the iron cores of the MCSR. The saturation degree of each magnetic valve is different when the same direct component of the magnetic flux is generated in the iron core, therefore current harmonics of different phases emerging, i.e. the total harmonics can be reduced. The magnetization characteristics and the mathematical model of the current harmonics of the MCSR are presented by introducing three parameters. The optimal values of the parameters that result in the smallest total harmonic distortion in the output current are calculated by a GA.
Findings
The simulation and experimental results are coincident with the theoretical analyses, which prove the effectiveness of the proposed method on harmonic suppression.
Practical implications
The method proposed in this paper can successfully reduce the current harmonics of the conventional MCR, including but not limited to the ASC. A prototype MCSR (540 kVA/10 kV) has been designed and constructed.
Originality/value
In this paper, a MCSR is proposed. The mathematical model of the MCSR for harmonic analysis is developed. The optimal parameters that result in the smallest THD in the output current are calculated. The mathematical model can be also used for the harmonic analysis of conventional MCRs.
Details
Keywords
Lieven Degroote, Lieven Vandevelde, Bert Renders and Johan Gyselinck
The aim is to develop a nonlinear transformer model to achieve an accurate model to obtain the frequency components of the magnetizing current based on the harmonic voltages at…
Abstract
Purpose
The aim is to develop a nonlinear transformer model to achieve an accurate model to obtain the frequency components of the magnetizing current based on the harmonic voltages at the primary and secondary side. So, it can easily be implemented in a harmonic load‐flow program.
Design/methodology/approach
The transformer model is based on the harmonic balance method. The electric and magnetic equations of the transformer are derived from the electric and magnetic equivalent circuits.
Findings
The transformer model can be easily implemented in a harmonic load‐flow program. The accuracy of the model has been shown by comparing it with a finite element simulation. The transformer model can be used with asymmetrical supply voltages, because different saturation levels of the phases can occur. There is a coupling between the phases which can be concluded out of the asymmetrical currents in the transformer under symmetrical supply voltages.
Research limitations/implications
The transformer model does not consider the iron losses and the interharmonics. In future work the transformer model will be used to study the harmonic losses in distribution networks, so the transformer losses due to these harmonics have to be considered. This can be achieved with a postcalculation process where the magnetic flux density is used to calculate the eddy current losses and the magnetic field intensity will be applied in a static Preisach model to quantify the hysteresis losses.
Practical implications
The model can be used in a harmonic load‐flow program in order to obtain more accurate simulations for the power system analysis and design.
Originality/value
The model presented in this paper is more detailed than similar papers found in literature (saturation of the yokes, coupling between the phases, interaction between different harmonics) and still it takes a brief simulation time.
Details
Keywords
A new method of spectral analysis has been proposed for non‐stationary harmonic analysis of corrosion processes. The current of a model circuit has been considered which would…
Abstract
A new method of spectral analysis has been proposed for non‐stationary harmonic analysis of corrosion processes. The current of a model circuit has been considered which would simulate a first‐order electrode reaction proceeding in conditions of a linearly changing electrode potential with a superimposed sinusoid signal. It has been shown that the Fourier transformation approach does not reflect the amplitude changes of harmonic components as a function of constant potential. In addition, it has been shown mathematically that application of Gabor transformation in spectral analysis is a means of obtaining the correct frequency components. The Gabor transform correctly reflects amplitude changes of harmonic components as a function of potential. Digital analysis of current changes by Gabor transformation unequivocally confirmed the usability of this method for harmonic analysis of corrosion processes.
Details
Keywords
U. Grasselli, R. Lamedica and A. Prudenzi
The present paper is intended to analyze time‐varying harmonic absorption of single‐phase non‐linear loads. To this aim, it is demonstrated that a continuous harmonic monitoring…
Abstract
The present paper is intended to analyze time‐varying harmonic absorption of single‐phase non‐linear loads. To this aim, it is demonstrated that a continuous harmonic monitoring can be of a certain utility, since this practice allows a better characterization of harmonic spectra and an improved understanding of impact due to the various stages of typical operation. Some selected results obtained from a wide monitoring activity performed in a lab are reported in this paper. The results are relevant to NL appliances with power ratings ranging from less than 10 W to several hundred watts, such as desktop PC, printer (both laser and ink‐jet), cell phone battery charger, and photocopier. The data thus obtained have been processed in order to determine probability density functions and distribution functions well evidencing the time‐varying behavior of harmonic content of the absorbed current. Since a continuous harmonic monitoring allows to follow the nearly instantaneous evolution of the physical quantities (voltage and current) a cross‐correlation based analysis of the various harmonic quantities among themselves is more meaningful than the monitoring activities providing longer observation time windows (up to minutes). The results obtained with such calculations can provide good indications for determining the origin of the time‐varying behavior as evidenced.
Details
Keywords
Oleksii V. Bialobrzheskyi, Dmytro RodKin and Andrii Gladyr
At the current stage of electrical technology development, it is relevant to take into account the quality of electrical energy. It can be implemented if an assessed energy…
Abstract
Purpose
At the current stage of electrical technology development, it is relevant to take into account the quality of electrical energy. It can be implemented if an assessed energy quality indicator is available. The amount of electrical energy is determined by active power, which is transmitted over a certain time period. In some cases, reactive power is included in the metering system. The distortion power is justifiably criticized and is not taken into account. The purpose of this paper consists in the substantiation of the indicator of the distortion of the periodic polyharmonic current electrical energy power, by separating from the instantaneous power such harmonics, which formed by same frequencies current and voltage harmonics.
Design/methodology/approach
Using the method of calculating linear polyharmonic current circuits, the following quantities are identified in instantaneous power: active, reactive and apparent powers of each harmonic. These components are known from references as canonical.
Findings
By the method of instantaneous power harmonic analysis, the components formed by current and voltage harmonics of the same frequency and different frequencies are distinguished.
Research limitations/implications
The RMS value of the instantaneous power due to current and voltage harmonics of different frequencies is justified in the work. This quantity allows you to distinguish the instantaneous power distortion level in comparison with the existing quantity.
Practical implications
The results can be used to assess the level of instantaneous power distortion level in commercial and technical metering systems.
Originality/value
The definition of instantaneous power distortion by extracting the canonical components from it and determining the root mean square value of the remainder is proposed.
Details
Keywords
Hongbo Qiu, Kaiqiang Hu, Ran Yi and Wei Yanqi
A large number of high-frequency harmonic voltages exist in the output voltage of the inverter, which will affect the performance of the motor. The purpose of this paper is to…
Abstract
Purpose
A large number of high-frequency harmonic voltages exist in the output voltage of the inverter, which will affect the performance of the motor. The purpose of this paper is to obtain the influence of high frequency harmonic voltage on the performance of the line start permanent magnet synchronous motor (LSPMSM) and reveal the mechanism of influence. The research results can provide help for the design of LSPMSM driven by inverter drives.
Design/methodology/approach
First, the actual output voltage data of the inverter is collected, and then the fundamental voltage and high frequency harmonic voltage data can be obtained by performing the fast Fourier transformation method on the voltage data. Second, the finite element model is established. During the finite element calculation, the obtained fundamental voltage and the main harmonic voltage components are used as the voltage source. To research the effect of high frequency harmonic voltage on the performance of motor, a reference group without high frequency harmonic voltage is set up, which is used to compare and analyze the effect of high-frequency harmonics on the performance of the motor. To verify the correctness of the model, a prototype based on the model parameters is manufactured, and then the back EMF experiment and load experiment are performed. The test data and calculation results are compared and analyzed.
Findings
The coupling relationship between high frequency time harmonic magnetic field and low frequency space harmonic magnetic field is obtained. The stator copper loss and rotor eddy-current loss are calculated and analyzed under normal supply voltage and abnormal supply voltage, and the influence mechanism is revealed
Originality/value
The coupling relationship between high frequency time harmonic magnetic field and low frequency space harmonic magnetic field is obtained. The sensitivity of the high frequency harmonic voltage to the stator copper loss and rotor eddy-current loss is obtained, and the mechanism of losses change is revealed.
Details
Keywords
Vasundhara Mahajan, Pramod Agarwal and Hari Om Gupta
The active power filter with two-level inverter needs a high-rating coupling transformer for high-power applications. This complicates the control and system becomes bulky and…
Abstract
Purpose
The active power filter with two-level inverter needs a high-rating coupling transformer for high-power applications. This complicates the control and system becomes bulky and expensive. The purpose of this paper is to motivate the use of multilevel inverter as harmonic filter, which eliminates the coupling transformer and allows direct control of the power circuit. The advancement in artificial intelligence (AI) for computation is explored for controller design.
Design/methodology/approach
The proposed scheme has a five-level cascaded H-bridge multilevel inverter (CHBMLI) as a harmonic filter. The control scheme includes one neural network controller and two fuzzy logic-based controllers for harmonic extraction, dc capacitor voltage balancing, and compensating current adjustment, respectively. The topology is modeled in MATLAB/SIMULINK and implemented using dSPACE DS1103 interface for experimentation.
Findings
The exhaustive simulation and experimental results demonstrate the robustness and effectiveness of the proposed topology and controllers for harmonic minimization for RL/RC load and change in load. The comparison between traditional PI controller and proposed AI-based controller is presented. It indicates that the AI-based controller is fast, dynamic, and adaptive to accommodate the changes in load. The total harmonic distortion obtained by applying AI-based controllers are well within the IEEE519 std. limits.
Originality/value
The simulation of high-power, medium-voltage system is presented and a downscaled prototype is designed and developed for implementation. The laboratory module of CHBMLI-based harmonic filter and AI-based controllers modeled in SIMULINK is executed using dSPACE DS1103 interface through real time workshop.
Details
Keywords
S. El Ferik, C.B. Ahmed, L. Ben Amor and S.A. Hussain
The purpose of this paper is to reduce the inrush current and dip in voltage for energy‐ saving purposes in relation to residential air‐conditioning systems.
Abstract
Purpose
The purpose of this paper is to reduce the inrush current and dip in voltage for energy‐ saving purposes in relation to residential air‐conditioning systems.
Design/methodology/approach
The paper focuses on the experimental harmonic investigation of a window‐type residential AC unit line current under time‐based soft‐starting control strategy. The control strategy assumes that only source voltage and current measurements are available. The soft‐starter is based on power electronic devices controlled through a firing signal generated by a programmed microcontroller during the first 500 ms.
Findings
The harmonic content shows the effect of the soft‐starter in exciting high‐frequency components of the line current. Harmonics investigations show that the high frequencies – even or odd multiples – of the fundamental line frequency are all excited by the soft‐starter approach. Some of these frequencies may harm the life cycle of the air‐conditioner.
Research limitations/implications
The real data harmonic analysis shows that the adopted approach excites the entire frequency spectrum of the signal. A better monitoring of the harmonics is required. A closed loop adaptive soft‐starting control may perform much better than a time‐based soft‐starting strategy.
Originality/value
The paper assesses the power quality related to time‐based soft‐starting strategy of a residential air‐conditioning system to reduce the inrush current and the dip in voltage, both with a serious effect on energy savings, especially when the AC load is around 65 per cent of the total power demand load.
Details
Keywords
Congliang Fei, Pengfei Xiahou and Fujun Wang
This study aims to focus on the grid connected inverter.
Abstract
Purpose
This study aims to focus on the grid connected inverter.
Design/methodology/approach
The grid connected inverter for harmonic suppression was designed, the topological structure of the inverter and the design of LCL filter were analyzed, then a PIR controller was proposed and finally simulation and experiment were carried out.
Findings
The simulation results showed that the distortion rates of the 5th, 7th and 11th harmonics under PIR control were 0.14%, 0.13% and 0.06%, respectively, which were significantly lower than that under PI control. The system test results also showed that the current waveform under PI control was rough and total harmonic distortion (THD) content was 3.8%; under PIR control, the grid connected current waveform was relatively smooth, with fewer spikes and burrs, and the THD content was 1.9%, indicating that the harmonics were effectively suppressed.
Originality/value
The experimental results verify that the inverter and PIR controller designed in this study are effective for harmonic suppression. This work makes some contributions to the improvement of the effect of harmonic suppression and promotion of the better application of grid connected inverter.
Details
Keywords
Lei Xiong, Hongjun Shi and Qixin Zhu
This study aims to construct a novel maximum power tracking control system for the direct drive permanent magnet synchronous generator (PMSG) of the wind energy conversion system…
Abstract
Purpose
This study aims to construct a novel maximum power tracking control system for the direct drive permanent magnet synchronous generator (PMSG) of the wind energy conversion system (WECS) to solve the following problems: how to effectively eliminate the system’s model parameter disturbances and speed up the dynamic performance of the system; and how to eliminate harmonics in WECS under different wind speeds.
Design/methodology/approach
To obtain the maximum output power of PMSG at WECS under different wind speeds, the following issues should be considered: (1) how to effectively eliminate the system’s model parameter disturbances and speed up the dynamic performance of the system; and (2) how to suppress system harmonics. For Problem 1, adding d–q compensation factors to active disturbance rejection control (ADRC) for the current loop realizes the d–q axis decoupling control, which speeds up the dynamic performance of the system. For Problem 2, the resonant controller is introduced into the ADRC for the current loop to suppress harmonic current in WECS under different wind speeds.
Findings
The simulation results demonstrate that the proposed control method is simpler and more reliable than conventional controllers for maximum power tracking.
Originality/value
Compared with traditional controllers, the proposed controller can speed up the dynamic performance of the system and suppress the current harmonic effectively, thus better achieving maximum power tracking.