Search results

1 – 10 of over 2000
Article
Publication date: 1 January 1991

A.K. Woollaston

Outlines the history and uses of copper tubing and its position inthe modern building industry. Discusses its various designations andtempers, its strength and ductility…

Abstract

Outlines the history and uses of copper tubing and its position in the modern building industry. Discusses its various designations and tempers, its strength and ductility, corrosion resistance, compatibility with other plumbing materials, suitability for use with potable water, its potential as a bacteriostat, its biofouling resistance and its availability in a range of sizes. Notes its position as a guaranteed British Standard quality product, and assesses the impact of Water Bylaws, Building Regulations and the British Standard Code of Practice on Water Supply on its use in building today. Explores other current and future applications of copper tube and extols its properties for health.

Details

Structural Survey, vol. 9 no. 1
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 1 August 1959

J.C. Spurr

In the summer of 1954, several A and B row tubes failed in one boiler of an R.C.N. light cruiser based on Esquimalt, B.C. These tube failures have been described in detail in…

Abstract

In the summer of 1954, several A and B row tubes failed in one boiler of an R.C.N. light cruiser based on Esquimalt, B.C. These tube failures have been described in detail in Corrosion. In brief, the chief phenomena observed were indications of overheating and intergranular cracking. A length of one of the burst tubes was forwarded to Naval Research Dockyard Laboratory, Halifax, for examination, and it was noticed that the failures were associated with considerable deposits of copper around the bursts. This paper describes the investigation conducted to determine the significance of these copper deposits, and their bearing on the failures.

Details

Anti-Corrosion Methods and Materials, vol. 6 no. 8
Type: Research Article
ISSN: 0003-5599

Article
Publication date: 7 June 2023

Mohamed Elmnefi and Waqas Al-Khazraji

One of the existing and commonly used solar energy harvesting devices is the parabolic trough solar collector (PTSC). Because of their ability to operate in low and medium…

Abstract

Purpose

One of the existing and commonly used solar energy harvesting devices is the parabolic trough solar collector (PTSC). Because of their ability to operate in low and medium temperatures, parabolic trough concentrators are widely used in power generation plants and industrial process heating applications. Therefore, the investigation of how different operating conditions affect these devices’ overall efficiency has received a great deal of attention in the recent decade. This study aims to enhance the thermal performance of the PTSC and reduce the system cost.

Design/methodology/approach

In the novel configuration, a noncirculated nanofluid absorbs solar radiation through a glass wall. The base fluid was synthetic oil (5W30), and the nanoparticles used were copper oxide. The heat captured is immediately absorbed by the water circulating inside the copper tube immersed in the nanofluid. ANSYS FLUENT 15.0 was used for carrying out computational fluid dynamics simulations for two models of single and triple copper tubes. The experimental results obtained from a test rig constructed for this purpose were compared with the numerical outcomes of the single copper tube model.

Findings

The findings of the simulation demonstrated that performance was superior for the single copper tube model over the triple copper tube model. The numerical findings of the single copper tube model were compared with the experimental results. The numerical and experimental results differed from 3.17% to 5.6%. Investigations were carried out to study the effects of varying the volumetric flow rate of (20, 40, 60 and 80 L/h) and water inlet temperatures of (300, 315 and 330 K) on the effectiveness and performance of the newly developed model. Additionally, two nanofluid volume fractions of 0.05% and 0.075% were used for investigating their effect on the performance of the novel configuration. According to the findings, the highest thermal efficiency of 55.31% was recorded at 0.075% concentration and 80 L/h volume flow rate.

Originality/value

In this study, a novel direct absorption solar collector configuration using a noncirculated nanofluid was designed to enhance the thermal efficiency of PTSC. This new approach makes it possible to boost the thermal performance of the PTSC and lower the system’s cost.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 33 no. 9
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 3 January 2023

Pravin Hindurao Yadav, Sandeep R. Desai and Dillip Kumar Mohanty

The purpose of this paper is to present investigations on the significant influence of the tube material and fin density on fluid elastic instability and vortex shedding in a…

Abstract

Purpose

The purpose of this paper is to present investigations on the significant influence of the tube material and fin density on fluid elastic instability and vortex shedding in a parallel triangular finned tube array subjected to water cross flow.

Design/methodology/approach

The experiment was conducted on finned tube arrays with a fin height of 6 mm and fin density of 3 fins per inch (fpi) and 9 fpi. A dedicated setup has been developed to examine fluid elastic instability and vortex shedding. Nine parallel triangular tube arrays with a pitch to tube diameter ratio of 1.78 were considered. The plain tube arrays, coarse finned tube arrays and fine finned tube arrays each of steel, copper and aluminium materials were tested. Plain tube arrays were tested to compare the results of the finned tube arrays having an effective tube diameter same as that of the plain tube.

Findings

A significant effect of fin density and tube material with a variable mass damping parameter was observed on the instability threshold. In the parallel triangular finned tube array subjected to water cross flow, a delay in the instability threshold was observed with an increase in fin density. For steel and aluminium tube arrays, the natural frequency is 9.77 Hz and 10.38 Hz, which is close to each other, whereas natural frequency of the copper tubes is 7.40 Hz. The Connors’ stability constant K for steel and aluminium tube arrays is 4.78 and 4.87, respectively, whereas it is 5.76 for copper tube arrays, which increases considerably compared to aluminum and steel tube arrays. The existence of vortex shedding is confirmed by comparing experimental results with Owen’s hypothesis and the Strouhal number and Reynolds number relationship.

Originality/value

This paper’s results contribute to understand the effect of tube materials and fin density on fluid elastic instability threshold of finned tube arrays subjected to water cross flow.

Details

World Journal of Engineering, vol. 21 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 1 August 2005

M.A. Alghoul, M.Y. Sulaiman, B.Z. Azmi and M.Abd. Wahab

To cover the main contributions and developments in solar thermal collectors through focusing on materials, heat transfer characteristics and manufacturing challenges.

4598

Abstract

Purpose

To cover the main contributions and developments in solar thermal collectors through focusing on materials, heat transfer characteristics and manufacturing challenges.

Design/methodology/approach

A range of published papers and internet research including research work on various solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube) were used. Evaluation of solar collectors performance is critiqued to aid solar technologies make the transition into a specific dominant solar collector. The sources are sorted into sections: finding an academic job, general advice, teaching, research and publishing, tenure and organizations.

Findings

Provides information about types of solar thermal collectors, indicating what can be added by using evacuated tube collectors instead of flat plate collectors and what can be added by using heat pipe collectors instead of evacuated tubes.

Research limitations/implications

Focusing only on three types of solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube).

Practical implications

Useful source of information for consultancy and impartial advice for graduate students planning to do research in solar thermal technologies.

Originality/value

This paper fulfils identified information about materials and heat transfer properties of materials and manufacturing challenges of these three solar thermal collectors.

Details

Anti-Corrosion Methods and Materials, vol. 52 no. 4
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 6 August 2019

Ab Kasaeian, Reza Daneshazarian, Fathollah Pourfayaz, Sahar Babaei, Mojgan Sheikhpour and Shima Nakhjavani

Because of its increased absorptance in fluid and reduced heat loss, direct absorption nanofluid (DANF) is receiving intense interest as an efficient way to harvest solar energy…

Abstract

Purpose

Because of its increased absorptance in fluid and reduced heat loss, direct absorption nanofluid (DANF) is receiving intense interest as an efficient way to harvest solar energy. This work aims to investigate, for the first time, the application of DANF in parabolic trough collectors (PTC), a promising collector for solar thermal systems.

Design/methodology/approach

A representative flow and heat transfer study of different fluids in a straight tube is conducted, and the basic energy equation and radiative transfer equations are numerically solved to obtain the fluid temperature distribution and energy conversion efficiency. Ethylene glycol (EG) and different concentrations of (i.e., 0.1-0.6 per cent) multi-wall carbon nanotubes (MWCNT) in EG are used as sample fluids. Four cases are studied for a traditional PTC (i.e., using metal tube) and a direct absorption PTC (i.e., using transparent tube) including a bare tube, a tube with an air-filled glass envelope and a tube with vacuumed glass envelop. The numerical results are verified by an experimental study using a copper-glass absorber tube, which reveals the good potential of DANFs.

Findings

Compared with a conventional PTC, using DANF shows an increase of 8.6 per cent and 6.5 K, respectively, in thermal efficiency and outlet temperature difference at a volume fraction (0.5 per cent) of nanoparticles. The results also show that the improvement in solar efficiency increases with increasing particle concentrations, and the vacuum insulated case has the highest efficiency.

Originality/value

In all previous studies, an important section was missing as the effect of photons on the direct solar absorption trough collector, which is considered in this study. This paper proposes a new concept of using direct solar absorption nanofluids for concentrated solar collectors and analyzes the performance of both absorptance and transmittance efficiency considerations. To reveal the potential of the new concept, an analytical model based on energy balance is developed, and two case studies are performed.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 30 no. 1
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 21 March 2016

Tan Chen, Wei-jun Zhang, Jian-jun Yuan, Liang Du and Ze-yu Zhou

This paper aims to present a different cooling method (water cooling) to protect all the mechanical/electrical components for Tokamak in-vessel inspection manipulator. The method…

Abstract

Purpose

This paper aims to present a different cooling method (water cooling) to protect all the mechanical/electrical components for Tokamak in-vessel inspection manipulator. The method is demonstrated effective through high temperature experiment, which provides an economical and robust approach for manipulators to work normally under high temperature.

Design/methodology/approach

The design of cooling system uses spiral copper tube structure, which is versatile for all types of key components of manipulator, including motors, encoders, drives and vision systems. Besides, temperature sensors are set at different positions of the manipulator to display temperature data to construct a close-loop feedback control system with cooling components.

Findings

The cooling system for the whole inspection manipulator working under high temperature is effective. Using insulation material such as rubber foam as component coating can significantly reduce the environmental heat transferred to cooling system.

Originality/value

Compared with nitrogen gas cooling applied in robotic protection design, although it is of less interest in prior research, water cooling method proves to be effective and economical through our high temperature experiment. This paper also presents an energetic analysis method to probe into the global process of water cooling and to evaluate the cooling system.

Details

Industrial Robot: An International Journal, vol. 43 no. 2
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 30 August 2021

Pravin Hindurao Yadav and Dillip kumar Mohanty

This paper aims to analyze the effect of fin geometry on mechanisms of flow induced vibration. Finned tube arrays are used in a heat exchanger to increase its efficiency…

Abstract

Purpose

This paper aims to analyze the effect of fin geometry on mechanisms of flow induced vibration. Finned tube arrays are used in a heat exchanger to increase its efficiency. Therefore, it is necessary to investigate the effect of geometric parameters of the fin fluid elastic instability and vortex shedding. In this paper, the effect of fin height, fin density and tube pitch ratio for parallel triangular tube array on fluid elastic instability and vortex shedding is analyzed.

Design/methodology/approach

Experimental analysis was carried out on a parallel triangular finned tube array with a pitch ratio of 1.79 subjected to water crossflow. The experimentation aims to study fluid elastic instability and vortex-induced vibration mechanism responsible for flow induced vibration for finned tube array. A fully flexible finned tube array of the copper tube was used with its base diameter of 19.05 mm and thickness of 2 mm. Over the tube surface, crimped fins of height 6 mm and the same material are welded spirally with fin density 8.47 mm and 2.82 mm. Experimental analysis was carried out on a test setup developed for the same. The results obtained for the finned tube array were compared with those for the plain tube array with the same base tube diameter.

Findings

For parallel triangular tube array of copper material, test results show that critical velocity increases with an increase in fin pitch density for low pitch tube array. Before the occurrence of instability, the rate of growth in tube vibrations is high for plain tubes compared to that with fin tubes. The results based on Owen’s hypothesis show vortex shedding before the occurrence of fluid elastic instability. The effect of fin geometry on vortex-induced forces is analyzed. For the tube array pattern understudy, the values of Conner’s constant K for coarse fin-tube and fine fin tube array are obtained, respectively, 6.14 and 7.25.

Originality/value

This paper fulfills the need for research on the effect of fin geometry on fluid elastic instability and Vortex shedding on a tube array subjected to water cross flow when the pitch ratio is less than two, i.e. with a low pitch ratio.

Details

World Journal of Engineering, vol. 20 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 31 May 2019

Athanasios Vazdirvanidis, Sofia Papadopoulou, Spyros Papaefthymiou, George Pantazopoulos and Dionysios Skarmoutsos

The purpose of this paper is to address the main aspects of ant-nest corrosion failure mechanism of a Cu tube in heating ventilation and air-conditioning (HVAC) installations and…

Abstract

Purpose

The purpose of this paper is to address the main aspects of ant-nest corrosion failure mechanism of a Cu tube in heating ventilation and air-conditioning (HVAC) installations and analyze the possible root causes through various case studies presented.

Design/methodology/approach

Failure investigation process includes mainly stereo-, light optical and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy for elemental microanalysis, as the main analytical techniques for material characterization and root-cause analysis.

Findings

The investigation findings, obtained from corrosion products’ analysis in conjunction to metallographic evaluation in transverse sections, illustrate the principal characteristics (“fingerprints”) of ant-nest (formicary) corrosion mechanism.

Originality/value

This paper which deals with the presentation of applied failure analysis/case histories’ investigation, summarizing the main aspects of an important and insidious type of Cu corrosion, taken place in HVAC installation systems and, on the other hand, presenting a complementary analysis of the chemical processes involved in the progressive failure mechanism constitutes an integrated approach, aiming to become a concise contribution to this subject.

Details

International Journal of Structural Integrity, vol. 10 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 December 1944

THE general appearance of this oil cooler is shown in Fig. 1. The photograph was taken after partial sectioning to show more clearly the general construction.

Abstract

THE general appearance of this oil cooler is shown in Fig. 1. The photograph was taken after partial sectioning to show more clearly the general construction.

Details

Aircraft Engineering and Aerospace Technology, vol. 16 no. 12
Type: Research Article
ISSN: 0002-2667

1 – 10 of over 2000