Search results

1 – 10 of over 10000
Article
Publication date: 19 April 2024

Mahesh Gaikwad, Suvir Singh, N. Gopalakrishnan, Pradeep Bhargava and Ajay Chourasia

This study investigates the impact of the fire decay phase on structural damage using the sectional analysis method. The primary objective of this work is to forecast the…

Abstract

Purpose

This study investigates the impact of the fire decay phase on structural damage using the sectional analysis method. The primary objective of this work is to forecast the non-dimensional capacity parameters for the axial and flexural load-carrying capacity of reinforced concrete (RC) sections for heating and the subsequent post-heating phase (decay phase) of the fire.

Design/methodology/approach

The sectional analysis method is used to determine the moment and axial capacities. The findings of sectional analysis and heat transfer for the heating stage are initially validated, and the analysis subsequently proceeds to determine the load capacity during the fire’s heating and decay phases by appropriately incorporating non-dimensional sectional and material parameters. The numerical analysis includes four fire curves with different cooling rates and steel percentages.

Findings

The study’s findings indicate that the rate at which the cooling process occurs after undergoing heating substantially impacts the axial and flexural capacity. The maximum degradation in axial and flexural capacity occurred in the range of 15–20% for cooling rates of 3 °C/min and 5 °C/min as compared to the capacity obtained at 120 min of heating for all steel percentages. As the fire cooling rate reduced to 1 °C/min, the highest deterioration in axial and flexural capacity reached 48–50% and 42–46%, respectively, in the post-heating stage.

Research limitations/implications

The established non-dimensional parameters for axial and flexural capacity are limited to the analysed section in the study owing to the thermal profile, however, this can be modified depending on the section geometry and fire scenario.

Practical implications

The study primarily focusses on the degradation of axial and flexural capacity at various time intervals during the entire fire exposure, including heating and cooling. The findings obtained showed that following the completion of the fire’s heating phase, the structural capacity continued to decrease over the subsequent post-heating period. It is recommended that structural members' fire resistance designs encompass both the heating and cooling phases of a fire. Since the capacity degradation varies with fire duration, the conventional method is inadequate to design the load capacity for appropriate fire safety. Therefore, it is essential to adopt a performance-based approach while designing structural elements' capacity for the desired fire resistance rating. The proposed technique of using non-dimensional parameters will effectively support predicting the load capacity for required fire resistance.

Originality/value

The fire-resistant requirements for reinforced concrete structures are generally established based on standard fire exposure conditions, which account for the fire growth phase. However, it is important to note that concrete structures can experience internal damage over time during the decay phase of fires, which can be quantitatively determined using the proposed non-dimensional parameter approach.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 7 August 2017

Tao Yan, Liang Ma, Shuo Zhao and Enlin Yu

This study aims to focus on numerical simulation investigations of phase transformation during cooling of 55SiMnMo steel, which is commonly applied to improve mechanical…

Abstract

Purpose

This study aims to focus on numerical simulation investigations of phase transformation during cooling of 55SiMnMo steel, which is commonly applied to improve mechanical properties.

Design/methodology/approach

A mathematical model based on the finite element method (FEM) and the phase transformation kinetics model has been proposed to predict microstructure changes during continuous cooling of 55SiMnMo steel. This model can be employed to analyze the variation of austenite, special upper bainite and lump-like composite structure with cooling time at different cooling rates.

Finding

According to the continuous cooling experiments, when the cooling rate is lower than 0.1°C/s, the special upper bainite is the only transformation product which decreases with increasing cooling rate; when the cooling rate is above 0.5°C/s, the transformation products include special upper bainite and lump-like composite structure. Meanwhile, the results of continuous cooling experiment verified the correctness of this finite element model.

Originality/value

This model has a great value for proper controlling of the cooling process which can improve the quality of hollow drill steel and increase the service life of the final product.

Details

World Journal of Engineering, vol. 14 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 12 December 2016

H. Kinjo, T. Hirashima, S. Yusa, T. Horio and T. Matsumoto

Based on heating tests and load-bearing fire tests, this paper aims to discuss the charring rate, the temperature distribution in the section and the load-bearing capacity of…

Abstract

Purpose

Based on heating tests and load-bearing fire tests, this paper aims to discuss the charring rate, the temperature distribution in the section and the load-bearing capacity of structural glued laminated timber beams not only during the heating phase during a 1-h standard fire in accordance with ISO 834-1 but also during the cooling phase.

Design/methodology/approach

Heating tests were carried out to confirm the charring rate and the temperature distribution in the cross-section of the beams. Loading tests under fire conditions were carried out to obtain the load-deformation behavior (i.e. the stiffness, maximum load and ductility) of the beam.

Findings

The temperature at the centroid reached approximately 30°C after 1 h and then increased gradually until reaching 110-200°C after 4 h, during the cooling phase. The maximum load of the specimen exposed to a 1-h standard fire was reduced to approximately 30 per cent of that of the specimen at ambient temperature. The maximum load of the specimen exposed to a 1-h standard fire and 3 h of natural cooling in the furnace was reduced to approximately 14 per cent. In case of taking into consideration of the strength reduction at elevated temperature, the reduction ratio of the calculated bending resistance agreed with that of the test results during not only heating phase but also cooling phase.

Originality/value

The results of this study state that it is possible to study on strength reduction in cooling phase for end of heating, timber structural which has not been clarified. It is believed that it is possible to appropriately evaluate the fire performance, including the cooling phase of the timber structural.

Details

Journal of Structural Fire Engineering, vol. 7 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 4 May 2020

Muhamad Zamri Yahaya, Nor Azmira Salleh, Soorathep Kheawhom, Balazs Illes, Muhammad Firdaus Mohd Nazeri and Ahmad Azmin Mohamad

The purpose of this paper is to investigate the morphology of intermetallic (IMC) compounds and the mechanical properties of SAC305 solder alloy under different cooling conditions.

2231

Abstract

Purpose

The purpose of this paper is to investigate the morphology of intermetallic (IMC) compounds and the mechanical properties of SAC305 solder alloy under different cooling conditions.

Design/methodology/approach

SAC305 solder joints were prepared under different cooling conditions/rates. The performance of three different etching methods was investigated: simple chemical etching, deep etching based on the Jackson method and selective removal of β-Sn by a standard three-electrode cell method. Phase and structural analyses were conducted by X-ray diffraction (XRD). The morphology of etched solder was examined by a field emission scanning electron microscope. The hardness evaluations of the solder joints were conducted by a Vickers microhardness tester.

Findings

The Ag3Sn network was significantly refined by the ice-quenching process. Further, the thickness of the Cu6Sn5 layer decreased with an increase in the cooling rate. The finer Ag3Sn network and the thinner Cu6Sn5 IMC layer were the results of the reduced solidification time. The ice-quenched solder joints showed the highest hardness values because of the refinement of the Ag3Sn and Cu6Sn5 phases.

Originality/value

The reduction in the XRD peak intensities showed the influence of the cooling condition on the formation of the different phases. The micrographs prepared by electrochemical etching revealed better observations regarding the shape and texture of the IMC phases than those prepared by the conventional etching method. The lower grain orientation sensitivity of the electrochemical etching method (unlike chemical etching) significantly improved the micrographs and enabled accurate observation of IMC phases.

Details

Soldering & Surface Mount Technology, vol. 32 no. 4
Type: Research Article
ISSN: 0954-0911

Keywords

Article
Publication date: 16 August 2013

Thomas Gernay and Mohamed Salah Dimia

The paper aims to give an insight into the behaviour of reinforced concrete columns during and after the cooling phase of a fire. The study is based on numerical simulations as…

Abstract

Purpose

The paper aims to give an insight into the behaviour of reinforced concrete columns during and after the cooling phase of a fire. The study is based on numerical simulations as these tools are frequently used in structural engineering. As the reliability of numerical analysis largely depends on the validity of the constitutive models, the development of a concrete model suitable for natural fire analysis is addressed in the study.

Design/methodology/approach

The paper proposes theoretical considerations supported by numerical examples to discuss the capabilities and limitations of different classes of concrete models and eventually to develop a new concrete model that meets the requirements in case of natural fire analysis. Then, the study performs numerical simulations of concrete columns subjected to natural fire using the new concrete model. A parametric analysis allows for determining the main factors that affect the structural behaviour in cooling.

Findings

Failure of concrete columns during and after the cooling phase of a fire is a possible event. The most critical situations with respect to delayed failure arise for short fires and for columns with low slenderness or massive sections. The concrete model used in the simulations is of prime importance and the use of the Eurocode model would lead to unsafe results.

Practical implications

The paper includes implications for the assessment of the fire resistance of concrete elements in a performance‐based environment.

Originality/value

The paper provides original information about the risk of structural collapse during cooling.

Details

Engineering Computations, vol. 30 no. 6
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 17 January 2022

Irindu Upasiri, Chaminda Konthesingha, Anura Nanayakkara, Keerthan Poologanathan, Gatheeshgar Perampalam and Dilini Perera

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel…

Abstract

Purpose

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel lipped channel sections negative fire performance, cavity insulation materials are utilized in the LSF configuration to enhance its fire performance. The applicability of lightweight concrete filling as cavity insulation in LSF and its effect on the fire performance of LSF are investigated under realistic design fire exposure, and results are compared with standard fire exposure.

Design/methodology/approach

A Finite Element model (FEM) was developed to simulate the fire performance of Light Gauge Steel Frame (LSF) walls exposed to realistic design fires. The model was developed utilising Abaqus subroutine to incorporate temperature-dependent properties of the material based on the heating and cooling phases of the realistic design fire temperature. The developed model was validated with the available experimental results and incorporated into a parametric study to evaluate the fire performance of conventional LSF walls compared to LSF walls with lightweight concrete filling under standard and realistic fire exposures.

Findings

Novel FEM was developed incorporating temperature and phase (heating and cooling) dependent material properties in simulating the fire performance of structures exposed to realistic design fires. The validated FEM was utilised in the parametric study, and results exhibited that the LSF walls with lightweight concrete have shown better fire performance under insulation and load-bearing criteria in Eurocode parametric fire exposure. Foamed Concrete (FC) of 1,000 kg/m3 density showed best fire performance among lightweight concrete filling, followed by FC of 650 kg/m3 and Autoclaved Aerated Concrete (AAC) 600 kg/m3.

Research limitations/implications

The developed FEM is capable of investigating the insulation and load-bearing fire ratings of LSF walls. However, with the availability of the elevated temperature mechanical properties of the LSF wall, materials developed model could be further extended to simulate the complete fire behaviour.

Practical implications

LSF structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel-lipped channel sections negative fire performance, cavity insulation materials are utilised in the LSF configuration to enhance its fire performance. The lightweight concrete filling in LSF is a novel idea that could be practically implemented in the construction, which would enhance both fire performance and the mechanical performance of LSF walls.

Originality/value

Limited studies have investigated the fire performance of structural elements exposed to realistic design fires. Numerical models developed in those studies have considered a similar approach as models developed to simulate standard fire exposure. However, due to the heating phase and the cooling phase of the realistic design fires, the numerical model should incorporate both temperature and phase (heating and cooling phase) dependent properties, which was incorporated in this study and validated with the experimental results. Further lightweight concrete filling in LSF is a novel technique in which fire performance was investigated in this study.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 3 August 2015

Motahareh Mokhtari Yazdi, Mohammad Sheikhzadeh and Seyed Ehsan Chavoshi

The purpose of this paper is to identify and evaluate the potential cooling contribution provided by a phase change material cooling vest as part of the total heat exchange…

Abstract

Purpose

The purpose of this paper is to identify and evaluate the potential cooling contribution provided by a phase change material cooling vest as part of the total heat exchange mechanism of the body and take in to account the negative side effects of wearing the cooling garments.

Design/methodology/approach

In this study, the three-part system of body-garment-environment has been simulated through the finite element method and the problem of heat exchange between these three parts has been solved with the help of computer modeling.

Findings

The results of this modeling showed that a large percentage of the cooling efficiency of cooling vest was neutralized by the negative effects of the vest that are weight, lack of breathability, and the effects on the thermal conductivity of the skin. Therefore, the net efficiency of the cooling vests resulted in a lower decrease in skin temperature compared to the state that the negative side effects were not included in the model.

Originality/value

Cooling power obtained with the help of cooling garments have been studied in previous studies using either human tests or manikins. But, what has been addressed less in previous studies relates to the negative effects of such equipment on the comfort of body, along with their cooling effect. So it is the first time witch the effect of side effects of such equipments are studied. Also modeling the real performance of cooling garments have not been done yet.

Details

International Journal of Clothing Science and Technology, vol. 27 no. 4
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 18 April 2018

Hitoshi Kinjo, Yusuke Katakura, Takeo Hirashima, Shuitsu Yusa and Kiyoshi Saito

This paper aims to discuss the fire performance of glulam timber beams based on their deflection behavior and load-bearing period, which were obtained from load-bearing fire tests…

Abstract

Purpose

This paper aims to discuss the fire performance of glulam timber beams based on their deflection behavior and load-bearing period, which were obtained from load-bearing fire tests under constant load conditions.

Design/methodology/approach

In this report, the fire performance, primarily deflection behavior and load-bearing period of glued laminated (glulam) timber beams will be discussed from the standpoint of load-bearing fire tests conducted during the cooling phase under constant load conditions. Then, based on the charring depth and the per section temperature transformation obtained from loading test results, the load-bearing capacity of the glulam timber beams will be discussed using the effective section method and the strength reduction factor, which will be calculated in accordance with the European standards for the design of timber structures (Eurocode 5).

Findings

In the cooling phase, the charring rate is decreases. However, as the temperature in the cross section rises, the deflection is increases. The failure mode was bending failure because of tensile failure of the lamina at the bottom of the beam. Moreover, a gap caused by shear failure in a growth ring in the beam cross-section in the vicinity of the centroid axis was observed. Shear failure was observed up until 1 to 3 h before end of heating. The calculated shear strength far exceeded the test results. Shear strength for elevated temperature of glued laminated timber is likely to decrease than the shear strength in Eurocode 5.

Originality/value

Unlike other elements, a characteristic problem of timber elements is that their load-bearing capacity decreases as they are consumed in a fire, and their bearing capacities may continue to degrade even after the fuel in the room has been exhausted. Therefore, the structural fire performance of timber elements should be clarified during not only the heating phase but also the subsequent cooling phase. However, there are few reports on the load-bearing capacity of timber elements that take the cooling phase after a fire into consideration.

Details

Journal of Structural Fire Engineering, vol. 9 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 March 1987

Y. Fukuoka, E. Matsumoto and M. Ishizuka

This paper describes one of the new package cooling technology concepts using low melting point alloys in order to perform high density packaging. Two kinds of cooling alloy…

Abstract

This paper describes one of the new package cooling technology concepts using low melting point alloys in order to perform high density packaging. Two kinds of cooling alloy materials, Bi/Sn/In and Bi/Pb/Sn/ln, whose melting points were less than 80°C and whose costs were low, were selected. The experimental substrate sample was fabricated by greensheet technology on which a tungsten metallised resistor heater was formed. Two kovar weld rings were brazed together to the top side and back side surfaces of the substrate individually. One kovar metal shell was laser welded to the top side weld ring in order to protect many devices. Another kovar metal shell, with a hole in the centre, was laser welded to the back side weld ring. The low melting point alloy was melted and poured into the back side kovar shell through the hole in a liquid state. After it was cooled and changed into a solid state, the hole was sealed hermetically with a small kovar metal cap by a laser beam. The authors performed a thermal experiment and confirmed that the substrate back surface temperature was fixed at the cooling alloy material's melting point for several minutes by thermal absorption while the low melting point alloy phase changed from its original solid state into a liquid state. This new package cooling technology is extremely useful for a high power motor drive circuit package which consists of many high power transistor chips and other analogue IC chips, and whose motor drive operation is performed intermittently for several minutes with some interval times.

Details

Microelectronics International, vol. 4 no. 3
Type: Research Article
ISSN: 1356-5362

Article
Publication date: 4 July 2016

Albert P.C. Chan, Wen Yi and Francis K.W. Wong

Extreme hot environments are prevalent in many occupational settings, and facilities management workers are no exception. Wearing suitable cooling garment is a useful means to…

626

Abstract

Purpose

Extreme hot environments are prevalent in many occupational settings, and facilities management workers are no exception. Wearing suitable cooling garment is a useful means to alleviate heat strain and improving performance at heat exposure. This paper aims to evaluate the effectiveness and applicability of the cooling vest across four selected fields (i.e. construction, outdoor cleaning and horticulture, kitchen work and work involved manual handling at the airport) and identify the shortcomings of the cooling vest used by the participating workers.

Design/methodology/approach

This study adopted a two-phase design: a quantitative questionnaire survey followed by qualitative in-depth interviews.

Findings

A remarkable physical strain alleviation (PSA) of 21.1 per cent (14.8 per cent in construction, 18.8 per cent in horticulture and cleaning, 27.4 per cent in kitchen and catering and 26.5 per cent in airport apron service) is achieved by the use of cooling vest in four industries. Despite the success of PSA, several shortcomings of the cooling vest were identified: easily stained color, heavy weight, short cooling time, inflexibility that presents a hazard around moving equipment, lack of industry-specific design, nondurable and thick fabric with poor permeability.

Originality/value

The findings of the current study do not only confirm the effectiveness of the cooling vest in alleviating heat strain and physical strain but also identify the major shortcomings upon which further improvements can be made.

Details

Facilities, vol. 34 no. 9/10
Type: Research Article
ISSN: 0263-2772

Keywords

1 – 10 of over 10000