Search results

1 – 10 of 841
Article
Publication date: 7 October 2013

Alessio Carofalo, Marta De Giorgi and Anna Morabito

The aim of this work is the development of a procedure able to model the highly irregular cellular structure of metallic foams on the basis of information obtained by X-ray…

Abstract

Purpose

The aim of this work is the development of a procedure able to model the highly irregular cellular structure of metallic foams on the basis of information obtained by X-ray tomographic analysis.

Design/methodology/approach

The geometric modelling is based on the feature “pore” characterized by an ellipsoidal shape. The data for the geometric parameters of the instances are obtained with a methodology which is driven by the pore volume distribution curve. This curve shows how much the cells, whose diameter belongs to a given dimensional range, contribute to the reduction of the total volume.

Findings

The presented methodology has been implemented into a CAD tool consisting of a Matlab routine identifying the instances of the feature “pore” and a CATIA's macro modelling the closed cells foam.

Originality/value

The presented methodology allows to obtain in an automatic way the CAD model of the complex structure of closed cell aluminium foam approximating by considerable accuracy both the density and the volume distribution of the real foams.

Details

Engineering Computations, vol. 30 no. 7
Type: Research Article
ISSN: 0264-4401

Keywords

Abstract

Details

The Digital Pill: What Everyone Should Know about the Future of Our Healthcare System
Type: Book
ISBN: 978-1-78756-675-0

Article
Publication date: 27 July 2012

Sadegh Rahmati, Farid Abbaszadeh and Farzam Farahmand

The purpose of this paper is to present an improved methodology for design of custom‐made hip prostheses, through integration of advanced image processing, computer aided design…

1272

Abstract

Purpose

The purpose of this paper is to present an improved methodology for design of custom‐made hip prostheses, through integration of advanced image processing, computer aided design (CAD) and additive manufacturing (AM) technologies.

Design/methodology/approach

The proposed methodology for design of custom‐made hip prostheses is based on an independent design criterion for each of the intra‐medullary and extra‐medullary portions of the prosthesis. The intra‐medullar part of the prosthesis is designed using a more accurate and detailed description of the 3D geometry of the femoral intra‐medullary cavity, including the septum calcar ridge, so that an improved fill and fit performance is achieved. The extra‐medullary portion of the prosthesis is designed based on the anatomical features of the femoral neck, in order to restore the original biomechanical characteristics of the hip joint. The whole design procedure is implemented in a systematic framework to provide a fast, repeatable and non‐subjective response which can be further evaluated and modified in a preplanning simulation environment.

Findings

The efficacy of the proposed methodology for design of custom‐made hip prostheses was evaluated in a case study on a hip dysplasia patient. The cortical bone was distinguished from cancellous in CT images using a thresholding procedure. In particular the septum calcar ridge could be recognized and was incorporated in the design to improve the primary stability of the prosthesis. The lateral and frontal views of the prosthesis, with the patient's images at the background, indicated a close geometrical match with the cortical bone of femoral shaft, and a good compatibility with the anatomy of the proximal femur. Also examination of the cross sections of the prosthesis and the patient's intra‐medullary canal at five critical levels revealed close geometrical match in distal stem but less conformity in proximal areas due to preserving the septum calcar ridge. The detailed analysis of the fitting deviation between the prosthesis and point cloud data of the patient's femoral intra‐medullary canal, indicated a rest fitting deviation of 0.04 to 0.11 mm in stem. However, relatively large areas of interference fit of −0.04 mm were also found which are considered to be safe and not contributing to the formation of bone cracks. The geometrical analysis of the extra‐medullary portion of the prosthesis indicated an anteversion angle of 12.5 degrees and a neck‐shaft angle of 131, which are both in the acceptable range. Finally, a time and cost effective investment casting technique, based on AM technology, was used for fabrication of the prosthesis.

Originality/value

The proposed design methodology helps to improve the fixation stability of the custom made total hip prostheses and restore the original biomechanical characteristics of the joint. The fabrication procedure, based on AM technology, enables the production of the customized hip prosthesis more accurately, quickly and economically.

Article
Publication date: 2 January 2009

Tomasz Grzywacz, Jan Sikora and Stefan Wójtowicz

The purpose of this paper is to introduce a method for increasing imaging quality in impedance tomography. The paper presents an optical method of shape virtualization, processing…

Abstract

Purpose

The purpose of this paper is to introduce a method for increasing imaging quality in impedance tomography. The paper presents an optical method of shape virtualization, processing algorithm draft and results of virtualization for sample objects.

Design/methodology/approach

In impedance tomography the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. When the object under investigation is filled with transparent medium, optical methods can provide information about its interior and estimate the shape of non‐transparent interjections. Computer graphics methods (e.g. ray tracing) can be used to simulate propagation of the light transmitted along straight lines within the object, and thus yield geometric data to better imaging. The process of setting up boundary conditions is then supplied with additional information about interior of the object, which can significantly improve solution of the forward problem in impedance tomography.

Findings

The visibility matrix includes information about the interior of the object. However, the information is incomplete since the scanning is done along one axis. In order to obtain all remaining data, scanning along three axes is required. On the basis of the visibility matrix, the shape and volume of the non‐transparent interjections are recovered and then estimated.

Originality/value

The biggest novelty is indeed the combination of methods used in optical tomography with those in impedance tomography.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 28 no. 1
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 26 October 2018

Tharmalingam Sivarupan, Mohamed El Mansori, Keith Daly, Mark Noel Mavrogordato and Fabrice Pierron

Micro-focus X-ray computed tomography (CT) can be used to quantitatively evaluate the packing density, pore connectivity and provide the basis for specimen derived simulations of…

Abstract

Purpose

Micro-focus X-ray computed tomography (CT) can be used to quantitatively evaluate the packing density, pore connectivity and provide the basis for specimen derived simulations of gas permeability of sand mould. This non-destructive experiment or following simulations can be done on any section of any size sand mould just before casting to validate the required properties. This paper aims to describe the challenges of this method and use it to simulate the gas permeability of 3D printed sand moulds for a range of controlling parameters. The permeability simulations are compared against experimental results using traditional measurement techniques. It suggests that a minimum volume of only 700 × 700 × 700 µm3 is required to obtain, a reliable and most representative than the value obtained by the traditional measurement technique, the simulated permeability of a specimen.

Design/methodology/approach

X-ray tomography images were used to reconstruct 3D models to simulate them for gas permeability of the 3D printed sand mould specimens, and the results were compared with the experimental result of the same.

Findings

The influence of printing parameters, especially the re-coater speed, on the pore connectivity of the 3D printed sand mould and related permeability has been identified. Characterisation of these sand moulds using X-ray CT and its suitability, compared to the traditional means, are also studied. While density and 3PB strength are a measure of the quality of the moulds, the pore connectivity from the tomographic images precisely relates to the permeability. The main conclusions of the present study are provided below. A minimum required sample size of 700 × 700 × 700 µm3 is required to provide representative permeability results. This was obtained from sand specimens with an average sand grain size of 140 µm, using the tomographic volume images to define a 3D mesh to run permeability calculations. Z-direction permeability is always lower than that in the X-/Y-directions due to the lower values of X-(120/140 µm) and Y-(101.6 µm) resolutions of the furan droplets. The anisotropic permeability of the 3D printed sand mould is mainly due to, the only adjustable, X-directional resolution of the furan droplets; the Y-directional resolution is a fixed distance, 102.6 µm, between the printhead nozzles and the Z-directional one is usually, 280 µm, twice the size of an average sand grain.A non-destructive and most representative permeability value can be obtained, using the computer simulation, on the reconstructed 3D X-ray tomography images obtained on a specific location of a 3D printed sand mould. This saves time and effort on printing a separate specimen for the traditional test which may not be the most representative to the printed mould.

Originality/value

The experimental result is compared with the computer simulated results.

Details

Rapid Prototyping Journal, vol. 25 no. 2
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 4 June 2019

Paweł Madejski, Paulina Krakowska, Edyta Puskarczyk, Magdalena Habrat and Mariusz Jędrychowski

The purpose of the paper was the application of computational fluid dynamics (CFD) techniques in fluid flow using Maxwell’s equation for partial slip modelling, estimating the…

Abstract

Purpose

The purpose of the paper was the application of computational fluid dynamics (CFD) techniques in fluid flow using Maxwell’s equation for partial slip modelling, estimating the flow parameters, and selecting tangential momentum accommodation coefficient (TMAC) for tight rock samples in permeability calculations.

Design/methodology/approach

The paper presents a numerical analysis of fluid flow in a low-porosity rock sample by using CFD. Modelling results allowed to determine mass flow rates in a rock sample and to calculate permeability values using a modified Darcy’s equation. Three-dimensional (3D) geometrical model of rock sample generated using computed X-ray tomography was used in the analysis. Steady-state calculations were carried out for defined boundary conditions in the form of pressure drop. The simulations were applied taking into account the slip phenomenon described by Maxwell’s slip model and TMAC.

Findings

Values of permeability were calculated for different values of TMAC, which vary from 0 to 1. Results in the form of gas mass flow rates were compared with the measured value of permeability for rock sample, which confirmed the high accuracy of the presented model.

Practical implications

Calculations of fluid flow in porous media using CFD can be used to determine rock samples’ permeability. In slip flow regime, Maxwell’s slip model can be applied and the empirical value of TMAC can be properly estimated.

Originality/value

This paper presents the usage of CFD, Maxwell’s equation for partial slip modelling, in fluid flow mechanism for tight rock samples. 3D geometric models were generated using created pre-processor (poROSE software) and applied in the raw form for simulation.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 30 no. 6
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 6 April 2021

Sonika Sahu, Piyush D. Ukey, Narendra Kumar, Ravi Pratap Singh and Mohd. Zahid Ansari

This study aims to generate different three-dimensional (3D) foam models using computer tomography (CT) scan and solid continuum techniques. The generated foam models were used to…

Abstract

Purpose

This study aims to generate different three-dimensional (3D) foam models using computer tomography (CT) scan and solid continuum techniques. The generated foam models were used to study deformation mechanism and the elastic-plastic behaviour with the existing experimental foam behaviour.

Design/methodology/approach

CT scan model was generated by combing 2D images of foam in MIMICS software. Afterwards, it was imported in ABAQUS/CAE software. However, solid continuum model was generated in ABAQUS/CAE software by using crushable foam properties. Then, the generated foam models were sets boundary conditions for a compression test.

Findings

CT scans capture the actual morphology of foam sample which may directly an image based finite element foam model. The sectional views of both the models were used to observe deformation mechanism on compression. The real compressive behaviour of foam was visualised in CT-Scan foam model. It was observed that CT-scan model was the more accurate modelling method than crushable foam model.

Originality/value

The internal structure of foam is very complex and difficult to analyse. Therefore, CT-scanning may be the accurate method for capturing the macro-level detailing of foam structure. A CT-scan foam model can be used for multiple times for mechanical analysis using a simulation software, which may reduce the manufacturing and the experimental cost and time.

Details

World Journal of Engineering, vol. 19 no. 3
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 1 November 2000

Jaroslav Mackerle

Gives a bibliographical review of the finite element methods (FEMs) applied in biomedicine from the theoretical as well as practical points of view. The bibliography at the end…

1347

Abstract

Gives a bibliographical review of the finite element methods (FEMs) applied in biomedicine from the theoretical as well as practical points of view. The bibliography at the end of the paper contains 748 references to papers, conference proceedings and theses/dissertations dealing with the finite element analyses and simulations in biomedicine that were published between 1985 and 1999.

Details

Engineering Computations, vol. 17 no. 7
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 19 October 2015

Janusz Domanski, Konstanty Skalski, Roman Grygoruk and Adrian Mróz

The purpose of this paper is to present the methodology of a design process of new lumbar intervertebral disc implants with specific emphasis on the use of rapid prototyping…

966

Abstract

Purpose

The purpose of this paper is to present the methodology of a design process of new lumbar intervertebral disc implants with specific emphasis on the use of rapid prototyping technologies. The verification of functionality of artificial intervertebral discs is also given. The paper describes the attempt and preliminary research to evaluate the properties of the intervertebral disc implant prototypes manufactured with the use of different rapid prototyping technologies, i.e. FDM – fused deposition modelling, 3DP – 3D printing and SLM – selective laser melting.

Design/methodology/approach

Based on the computed tomography (CT) scan data, the anatomical parameters of lumbar spine bone tissue were achieved, which were the bases for the design-manufacture process carried out with the use of computer-aided designing/computer-aided engineering/computer-aided manufacturing systems. In the intervertebral disc implant design process, three RP technologies: FDM, 3DP and SLM were used for solving problems related to the reconstruction of geometry and functionality of the disc. Some preliminary tests such as measurement of roughness and structural analyses of material of prototypes made by different prototyping technologies were performed.

Findings

This paper allowed the authors to elaborate and patent two new intervertebral disc implants. Because the implant designs are parametrical ones with relation to lumbar bone tissue properties measured on CT scans, they can be also made for individual patients. We also compared some of the properties of intervertebral implants prototypes made with the use of FDM, 3DP and SLM technologies.

Originality/value

The paper presents the new intervertebral disc implants and their manufacturing by rapid prototyping. The methodology of designing intervertebral disc implant is shown. Some features of the methodology make it useful for preoperative planning of intervertebral disc surgery, as well.

Details

Rapid Prototyping Journal, vol. 21 no. 6
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 6 July 2012

Dagmara M. Dołęga and Jerzy Barglik

The purpose of this paper is to enable the correct selection of the radiofrequency thermal ablation (RFTA) process parameters for an individual patient by applying a computer

Abstract

Purpose

The purpose of this paper is to enable the correct selection of the radiofrequency thermal ablation (RFTA) process parameters for an individual patient by applying a computer modelling of RFTA.

Design/methodology/approach

The model is based on the X‐ray computer tomography images of the primary and metastatic hepatic tumours. The authors used the professional package of FLUX3D to generate the geometric models, assign materials properties, assign boundary conditions, perform mesh, carry out coupled thermo‐electromagnetic analysis and for post processing. The distribution of temperature and electric potential in the tissues of tumour and liver had been obtained as main results of the calculations.

Findings

The computational results show that the RFTA algorithm is effective in solving this practical problem. The computational results show that the selection of the type of electrodes used in the RFTA process is as important as the correct selection of the process parameters, i.e. voltage and frequency.

Originality/value

The paper presents a method to simulate the RFTA process and to select the process parameters.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 31 no. 4
Type: Research Article
ISSN: 0332-1649

Keywords

1 – 10 of 841