Search results

1 – 10 of over 2000
Article
Publication date: 21 February 2024

Mohan Kumar K and Arumaikkannu G

The purpose of this paper is to compare the influence of relative density (RD) and strain rates on failure mechanism and specific energy absorption (SEA) of polyamide lattices…

Abstract

Purpose

The purpose of this paper is to compare the influence of relative density (RD) and strain rates on failure mechanism and specific energy absorption (SEA) of polyamide lattices ranging from bending to stretch-dominated structures using selective laser sintering (SLS).

Design/methodology/approach

Three bending and two stretch-dominated unit cells were selected based on the Maxwell stability criterion. Lattices were designed with three RD and fabricated by SLS technique using PA12 material. Quasi-static compression tests with three strain rates were carried out using Taguchi's L9 experiments. The lattice compressive behaviour was verified with the Gibson–Ashby analytical model.

Findings

It has been observed that RD and strain rates played a vital role in lattice compressive properties by controlling failure mechanisms, resulting in distinct post-yielding responses as fluctuating and stable hardening in the plateau region. Analysis of variance (ANOVA) displayed the significant impact of RD and emphasised dissimilar influences of strain rate that vary to cell topology. Bending-dominated lattices showed better compressive properties than stretch-dominated lattices. The interesting observation is that stretch-dominated lattices with over-stiff topology exhibited less compressive properties contrary to the Maxwell stability criterion, whereas strain rate has less influence on the SEA of face-centered and body-centered cubic unit cells with vertical and horizontal struts (FBCCXYZ).

Practical implications

This comparative study is expected to provide new prospects for designing end-user parts that undergo various impact conditions like automotive bumpers and evolving techniques like hybrid and functionally graded lattices.

Originality/value

To the best of the authors' knowledge, this is the first work that relates the strain rate with compressive properties and also highlights the lattice behaviour transformation from ductile to brittle while the increase of RD and strain rate analytically using the Gibson–Ashby analytical model.

Details

Rapid Prototyping Journal, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 28 August 2019

Fatemeh FaghihKhorasani, Mohammad Zaman Kabir, Mehdi AhmadiNajafabad and Khosrow Ghavami

The purpose of this paper is to provide a method to predict the situation of a loaded element in the compressive stress curve to prevent failure of crucial elements in…

Abstract

Purpose

The purpose of this paper is to provide a method to predict the situation of a loaded element in the compressive stress curve to prevent failure of crucial elements in load-bearing masonry walls and to propose a material model to simulate a compressive element successfully in Abaqus software to study the structural safety by using non-linear finite element analysis.

Design/methodology/approach

A Weibull distribution function was rewritten to relate between failure probability function and axial strain during uniaxial compressive loading. Weibull distribution parameters (shape and scale parameters) were defined by detected acoustic emission (AE) events with a linear regression. It was shown that the shape parameter of Weibull distribution was able to illustrate the effects of the added fibers on increasing or decreasing the specimens’ brittleness. Since both Weibull function and compressive stress are functions of compressive strain, a relation between compressive stress and normalized cumulative AE hits was calculated when the compressive strain was available. By suggested procedures, it was possible to monitor pretested plain or random distributed short fibers reinforced adobe elements (with AE sensor and strain detector) in a masonry building under uniaxial compression loading to predict the situation of element in the compressive stress‒strain curve, hence predicting the time to element collapse by an AE sensor and a strain detector. In the predicted compressive stress‒strain curve, the peak stress and its corresponding strain, the stress and strain point with maximum elastic modulus and the maximum elastic modulus were predicted successfully. With a proposed material model, it was illustrated that the needed parameters for simulating a specimen in Abaqus software with concrete damage plasticity were peak stress and its corresponding strain, the stress and strain point with maximum elastic modulus and the maximum elastic modulus.

Findings

The AE cumulative hits versus strain plots corresponding to the stress‒strain curves can be divided into four stages: inactivity period, discontinuous growth period, continuous growth period and constant period, which can predict the densifying, linear, non-linear and residual stress part of the stress‒strain relationship. By supposing that the relation between cumulative AE hits and compressive strain complies with a Weibull distribution function, a linear analysis was conducted to calibrate the parameters of Weibull distribution by AE cumulative hits for predicting the failure probability as a function of compressive strain. Parameters of m and θ were able to predict the brittleness of the plain and tire fibers reinforced adobe elements successfully. The calibrated failure probability function showed sufficient representation of the cumulative AE hit curve. A mathematical model for the stress–strain relationship prediction of the specimens after detecting the first AE hit was developed by the relationship between compressive stress versus the Weibull failure probability function, which was validated against the experimental data and gave good predictions for both plain and short fibers reinforced adobe specimens. Then, the authors were able to monitor and predict the situation of an element in the compressive stress‒strain curve, hence predicting the time to its collapse for pretested plain or random distributed short fibers reinforced adobe (with AE sensor and strain detector) in a masonry building under uniaxial compression loading by an AE sensor and a strain detector. The proposed model was successfully able to predict the main mechanical properties of different adobe specimens which are necessary for material modeling with concrete damage plasticity in Abaqus. These properties include peak compressive strength and its corresponding axial strain, the compressive strength and its corresponding axial strain at the point with maximum compressive Young’s modulus and the maximum compressive Young’s modulus.

Research limitations/implications

The authors were not able to decide about the effects of the specimens’ shape, as only cubic specimens were chosen; by testing different shape and different size specimens, the authors would be able to generalize the results.

Practical implications

The paper includes implications for monitoring techniques and predicting the time to the collapse of pretested elements (with AE sensor and strain detector) in a masonry structure.

Originality/value

This paper proposes a new method to monitor and predict the situation of a loaded element in the compressive stress‒strain curve, hence predicting the time to its collapse for pretested plain or random distributed short fibers reinforced adobe (with AE sensor and strain detector) in a masonry building under uniaxial compression load by an AE sensor and a strain detector.

Article
Publication date: 20 December 2021

Amit Deb Nath, Md. Ikramul Hoque, Shuvo Dip Datta and Fahim Shahriar

The current study mainly focuses on the effect of varying diameter recycled steel fibers (RSF) on mechanical properties of concrete prepared with 25 and 50% of recycled coarse…

Abstract

Purpose

The current study mainly focuses on the effect of varying diameter recycled steel fibers (RSF) on mechanical properties of concrete prepared with 25 and 50% of recycled coarse aggregate (RCA) as well as 100% natural aggregate (NA). Two types of RSF with 0.84 mm and 1.24 mm diameter having 30 mm length were incorporated into normal and recycled aggregate concrete (RAC).

Design/methodology/approach

The fresh behavior, compressive, splitting tensile, flexural strengths and modulus of elasticity of all the mixes were investigated to evaluate the mechanical properties of RACs. In addition, specimen crack and testing co-relation were analyzed to evaluate fiber response in the RAC.

Findings

According to the experimental results, it was observed that mechanical properties decreased with the increment replacement of NA by RCA. However, the RSF greatly improves the mechanical properties of both normal concrete and RACs. Moreover, mixes containing 1.24 mm diameter RSF had a more significant positive impact on mechanical properties than mixes containing 0.84 mm diameter RSF. The 0.84 mm and 1.24 mm RSF addition improved the mixes' compressive, splitting tensile and flexural strength by 10%–19%, 19%–30% and 3%–11%, respectively when compared to the null fiber mix. Therefore, based on the mechanical properties, the 1.24 mm diameter of RSF with 25% replacement of RCA was obtained as an optimum solution in terms of performance improvement, environmental benefit and economic cost.

Practical implications

The practice of RCA in construction is a long-term strategy for reducing natural resource extraction and the negative ecological impact of waste concrete.

Originality/value

This is the first study on the effects of varying size (0.84 mm and 1.24 mm diameter) RSF on the mechanical properties of RAC. Additionally, varying sizes of RSF and silica fume added a new dimension to the RAC.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 8 October 2020

Mingkang Zhang, Yongqiang Yang, Wentao Qin, Shibiao Wu, Jie Chen and Changhui Song

This study aims to focus on the optimized design and mechanical properties of gradient triply periodic minimal surface cellular structures manufactured by selective laser melting.

Abstract

Purpose

This study aims to focus on the optimized design and mechanical properties of gradient triply periodic minimal surface cellular structures manufactured by selective laser melting.

Design/methodology/approach

Uniform and gradient IWP and primitive cellular structures have been designed by the optimized function in MATLAB, and selective laser melting technology was applied to manufacture these cellular structures. Finite element analysis was applied to optimize the pinch-off problem, and compressive tests were carried out for the evaluation of mechanical properties of gradient cellular structures.

Findings

Finite element analysis shows that the elastic modulus of IWP increased as design parameter b increased, and then decreased when parameter b is higher than 5.5. The highest elastic modulus of primitive increased by 89.2% when parameter b is 6. The compressive behavior of gradient IWP and primitive shows a layer-by-layer way, and elastic modulus and first maximum compressive strength of gradient primitive are higher than that of gradient IWP. The effective energy absorption of gradient cellular structures increased as the average porosity decreased, and the effective energy absorption of gradient primitive is about twice than that of gradient IWP.

Originality/value

This paper presents an optimized design method for the pinch-off problem of gradient triply periodic minimal surface cellular structures.

Details

Rapid Prototyping Journal, vol. 26 no. 10
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 10 April 2017

Mojtaba Labibzadeh, Mojtaba Zakeri and Abdol Adel Shoaib

The purpose of this paper is to present a new method for determining the input parameters of the concrete damaged plasticity (CDP) model of ABAQUS standard software. The existing…

1104

Abstract

Purpose

The purpose of this paper is to present a new method for determining the input parameters of the concrete damaged plasticity (CDP) model of ABAQUS standard software. The existing available methods in the literatures are case sensitive, i.e., they give different input parameters of CDP for a unique concrete class used in different finite element (FE) simulation of concrete structures. In this study, the authors attempt to introduce a new approach for the identification of the input parameters of the CDP model, which guarantees the uniqueness and precision of the model. In other words, by this method, the input parameters obtained for a specific concrete class with a unique characteristic strength can be used for FE simulation of the different concrete structures which were constructed by this concrete without the need to additional modifications raised from any new application.

Design/methodology/approach

For the input parameter identification of the CDP model, different standard tests of plain concrete are simulated by the ABAQUS standard software. These test simulations are performed for various set of input parameters. In the end, those set of input parameters which represents the best curve fitting with the experimental results is chosen as the optimum parameters.

Findings

By comparison of the FE simulation results obtained from the ABAQUS for two different concrete structures using the proposed input parameters for the CDP model with the experimental results, it was shown that the presented method for determining those parameters can guarantee the uniqueness and precision of the CDP model in simulation.

Originality/value

The method described for determining the input parameters of the CDP model of the ABAQUS standard software has not been previously presented.

Details

International Journal of Structural Integrity, vol. 8 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 December 2000

N. Venkataraman, S. Rangarajan, M.J. Matthewson, B. Harper, A. Safari, S.C. Danforth, G. Wu, N. Langrana, S. Guceri and A. Yardimci

Fused deposition of ceramics (FDC) is a solid freeform fabrication technique based on extrusion of highly loaded polymer systems. The process utilizes particle loaded…

2907

Abstract

Fused deposition of ceramics (FDC) is a solid freeform fabrication technique based on extrusion of highly loaded polymer systems. The process utilizes particle loaded thermoplastic binder feedstock in the form of a filament. The filament acts as both the piston driving the extrusion and also the feedstock being deposited. Filaments can fail during FDC via buckling, when the extrusion pressure needed is higher than the critical buckling load that the filament can support. Compressive elastic modulus determines the load carrying ability of the filament and the viscosity determines the resistance to extrusion (or extrusion pressure). A methodology for characterizing the compressive mechanical properties of FDC filament feedstocks has been developed. It was found that feedstock materials with a ratio (Ea) greater than a critical value (3×105 to 5×105 s‐1) do not buckle during FDC while those with a ratio less than this range buckle.

Details

Rapid Prototyping Journal, vol. 6 no. 4
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 6 August 2018

Ebrahim Farajpourbonab, Hossein Showkati and Sunil Kute

The main function of the castellation process is making I-sections stiffer by increasing the height of web and supplying a higher moment capacity of primary axis than plain-webbed…

102

Abstract

Purpose

The main function of the castellation process is making I-sections stiffer by increasing the height of web and supplying a higher moment capacity of primary axis than plain-webbed members of the same weight. In addition, it optimizes the use of heavy, costly constructional steel material and provides good services accessibility. The purpose of this study was to investigate the strength and buckling behavior of axially loaded castellated cruciform steel columns using finite element analysis. Although a significant body of research exists on the failure of different columns, there is no proper criterion introduced to determine the point of buckling in the equilibrium path of an imperfect column.

Design/methodology/approach

This paper considers a wide range of practical geometric dimensions and various end conditions using ANSYS software. Findings are reported for about 224 samples of castellated cruciform I-shaped sections, and a simplified approach to evaluate buckling capacity of castellated columns, using the slenderness-load curve, is developed. In addition, the axial compressive capacities of those steel sections are investigated numerically in the current study.

Findings

The results of nonlinear analyses of these columns revealed that the load-carrying capacity of castellated cruciform steel columns far outweighs and is more appropriate than that of the traditional cruciform steel columns. In the present paper, new geometric criteria have been introduced having the ability to cover different types of columns. It shows the critical load of columns in the range of elastic and inelastic behavior.

Practical implications

This study can provide a background for practical engineering applications and design specifications for steel structures with castellated sections. In the present paper, new geometric criteria have been introduced having the ability to cover different types of columns. It shows the critical load of columns showing both elastic and inelastic behavior. Because this method showed reliable performance, it can be used during experimental tests for detecting buckling point.

Originality/value

This study can provide background for practical engineering applications and design specifications for steel structures with castellated sections; also, a physical criterion has been defined for calculating the buckling load of real columns.

Details

World Journal of Engineering, vol. 15 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 25 February 2022

Mojtaba Labibzadeh, Mohsen Bagheri, Abdolghafour Khademalrasoul and Khandaker M.A. Hossain

This paper aims to study, the effects of opening shape, size and position as well as the aspect (height-to-length) ratio on the shear capacity, stiffness, ductility and energy…

Abstract

Purpose

This paper aims to study, the effects of opening shape, size and position as well as the aspect (height-to-length) ratio on the shear capacity, stiffness, ductility and energy dissipation capacity of triple-skin profiled steel-concrete composite shear wall (TSCSW) and investigate and compare them to those of concrete-stiffened steel plate shear walls (CSPSW). Two kinds of opening, circular and square, with different sizes and positions and two aspect ratios of 1:1 and 3:1 are considered in the simulations.

Design/methodology/approach

This study presents a novel TSCSW and compares its behavior with the existing CSPSW under the effect of monotonic and cyclic loadings. TSCSW is composed of three corrugated steel plates filled with concrete. The two external side plates are connected to the concrete core by means of several intermediate fasteners and the third one is an inner steel plate embedded within the concrete panel. The internal plate is a buckling restrained plate surrounded by concrete. This is the main superiority of TSCSW over other kinds of existing composite shear walls.

Findings

The results show that the shear capacity and the energy dissipation capacity of the proposed composite wall, TSCSW, are respectively about 16 and 12% higher than those of CSPSW when there is no opening. If an opening is considered in the wall, as the size of the opening is increased, the shear capacity, stiffness, ductility and absorbed energy of the two walls are decreased similarly. The destructive effect of square openings on the performance of the walls is more than that of circular openings.

Originality/value

This is an original work.

Details

International Journal of Structural Integrity, vol. 13 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 27 April 2023

Vadiraj Rao, N. Suresh and G.P. Arun Kumar

The majority of previous studies made on Recycled Concrete Aggregates (RCA) are limited to the utilisation of non-structural grade concrete due to unfavourable physical…

Abstract

Purpose

The majority of previous studies made on Recycled Concrete Aggregates (RCA) are limited to the utilisation of non-structural grade concrete due to unfavourable physical characteristics of RCA including the higher absorption of water, tending to increased water requirement of concrete. This seriously limits its applicability and as a result it reduces the usage of RCA in structural members. In the present study, the impact of hybrid fibres on cracking behaviour of RCA concrete beams along with the inclusion of reinforcing steel bars under two-point loading system exposed to different sustained elevated temperatures are being investigated.

Design/methodology/approach

RCA is substituted for Natural Coarse Aggregates (NCA) at 0, 50 and 100 percentages. The study involves testing of 150 mm cubes and beams of size (700 × 150 × 150) mm, i.e. with steel reinforcing bars along with the addition of 0.35% Steel fibres+ 0.15% polypropylene fibres. The specimens are being exposed to temperatures from 100° to 500°C with 100° interval for 2 h. Studies were made on the post crack analysis, which includes the measurement of crack width, crack length and load at first crack. The crack patterns were analysed in order to understand the effect of fibres and RCA at sustained elevated temperatures.

Findings

The result shows that ultimate load carrying capacity of reinforced concrete beams and load at first crack decreases with the raise in temperatures and increased percentage of RCA content in the mix. Further that 100% RCA replacement specimens showed lesser cracks when compared to the other mixes and the inclusion of fibres enhances the flexural capacity of members highlighting the importance of fibres.

Practical implications

RCA can be used for structural purposes and the study can be projected for assessing the performance of real structures with the extent of fire damage when recycled aggregates are used.

Social implications

Most of recycled materials can be used in the regular concrete which solves two problems namely avoiding the dumping of C&D waste and preventing the usage of natural aggregates. Hence the study provides sustainable option for the production of concrete.

Originality/value

The reduction in capacity of flexural members due to the utilisation of recycled aggregates can be negated by the usage of fibres. Hence improved flexural performance is observed for specimens with fibres at sustained elevated temperatures.

Details

Journal of Structural Fire Engineering, vol. 14 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 5 February 2021

Alwyn Varghese, Anand N., Diana Andrushia and Prince Arulraj

Aim of this research work is to examine the stress–strain behavior and modulus of elasticity of fiber-reinforced concrete (FRC) exposed to elevated temperature. The purpose of…

Abstract

Purpose

Aim of this research work is to examine the stress–strain behavior and modulus of elasticity of fiber-reinforced concrete (FRC) exposed to elevated temperature. The purpose of this paper is to study the effect of standard fire exposure on the mechanical and microstructure characteristics of concrete specimens with different strength grade.

Design/methodology/approach

An electrical bogie hearth furnace was developed to simulate the ISO 834 standard fire curve. Specimens were exposed to high temperatures of 821°C, 925°C and 986°C for the duration of 30, 60 and 90 min, respectively, as per standard fire curve. Peak stress, peak strain, modulus of elasticity and damage level of heated concrete specimens were evaluated by experimental investigation. SEM-based microstructure investigation has been carried out to analyze the microstructure characteristics of heated concrete specimens.

Findings

The results revealed that carbon fiber reinforced concrete was found to be better than the FRC made with other fibers on improving the modulus of elasticity of concrete. An empirical relationship has been established to predict the modulus of elasticity of temperature exposed specimens with different type of fiber and grade of concrete. In comparison with low melting point fibers, high melting point fibers exhibited higher modulus of elasticity under all tested conditions. Surface damage and porosity level of concrete with carbon and basalt fibers were found to be lower than other FRC.

Originality/value

Empirical relationship was developed to determine the modulus of elasticity of concrete exposed to elevate temperature, and this will be useful for concrete design applications. This research work may be useful for finding the residual compressive strength of concrete exposed to elevate temperature. So that it will be helpful to identify the suitable repair/retrofitting technique for reinforced concrete elements.

Details

World Journal of Engineering, vol. 18 no. 3
Type: Research Article
ISSN: 1708-5284

Keywords

1 – 10 of over 2000