Search results

1 – 10 of 243
Article
Publication date: 17 December 2021

Yousef Al Rjoub, Ala Obaidat, Ahmed Ashteyat and Khalid Alshboul

This study aims to conduct an experimental study and finite element model (FEM) to investigate the flexural behavior of heat-damaged beams strengthened/repaired by hybrid…

Abstract

Purpose

This study aims to conduct an experimental study and finite element model (FEM) to investigate the flexural behavior of heat-damaged beams strengthened/repaired by hybrid fiber-reinforced polymers (HFRP).

Design/methodology/approach

Two groups of beams of (150 × 250 × 1,200) mm were cast, strengthened and repaired using different configurations of HFRP and tested under four-point loadings. The first group was kept at room temperature, while the second group was exposed to a temperature of 400°C.

Findings

It was found that using multiple layers of carbon fiber-reinforced polymer (CFRP) and glass fiber-reinforced polymer (GFRP) enhanced the strength more than a single layer. Also, the order of two layers of FRP showed no effect on flexural behavior of beams. Using a three-layer scheme (attaching the GFRP first and followed by two layers of CFRP) exhibited increase in ultimate load more than the scheme attached by CFRP first. Furthermore, the scheme HGC (heated beam repaired with glass and carbon, in sequence) allowed to achieve residual flexural capacity of specimen exposed to 400°C. Typical flexural failure was observed in control and heat-damaged beams, whereas the strengthened/repaired beams failed by cover separation and FRP debonding, however, specimen repaired with two layers of GFRP failed by FRP rupture. The FEM results showed good agreement with experimental results.

Originality/value

Few researchers have studied the effects of HFRP on strengthening and repair of heated, damaged reinforced concrete (RC) beams. This paper investigates, both experimentally and analytically, the performance of externally strengthened and repaired RC beams, in flexure, with different FRP configurations of CFRP and GFRP.

Details

Journal of Structural Fire Engineering, vol. 13 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 2 September 2019

Mahfoud Touhari and Ratiba Kettab Mitiche

Covering a fiber-reinforced concrete column (fiber reinforced plastic (FRP)) improves the performance of the column primarily. The purpose of this paper is to investigate the…

Abstract

Purpose

Covering a fiber-reinforced concrete column (fiber reinforced plastic (FRP)) improves the performance of the column primarily. The purpose of this paper is to investigate the behavior of small FRP concrete columns that are subject to axial pressure loading, in order to study the effect of many parameters on the effectiveness of FRP couplings on circular and square concrete columns.

Design/methodology/approach

These parameters include the shape of the browser (circular and square), whole core and cavity, square radius of square columns, concrete strength (low strength, normal and high), type of FRP (carbon and glass) and number of FRP (1–3) layers. The effective fibrillation failure strain was investigated and the effect of effective lateral occlusion pressure.

Findings

The results of the test showed that the FRP-coated columns improved significantly the final conditions of both the circular and square samples compared to the unrestricted columns; however, improvement of square samples was not as prominent as improvement in circular samples. The results indicated that many parameters significantly affected the behavior of FRP-confined columns. A new model for predicting compressive force and the corresponding strain of FRP is presented. A good relationship is obtained between the proposed equations and the current experimental results.

Originality/value

The average hoop strain in FRP wraps at rupture in FRP-confined concrete specimens can be much lower than that given by tensile coupon tests, meaning the theoretical assumption that the FRP-confined concrete cylinder ruptures when the FRP material tensile strength attained at its maximum is not suitable. Based on this observation, the effective peak strength and corresponding strain formula for FRP concrete confined columns must be based on the effective hoop rupture strain composite materials.

Details

International Journal of Structural Integrity, vol. 11 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 May 2019

Prashant Rangrao Jagtap and Sachin M. Pore

This study aims to use carbon fiber-reinforced polymer (CFRP) laminates to strengthen the compression flange of structural I-beam so as to avoid local failure of compression…

Abstract

Purpose

This study aims to use carbon fiber-reinforced polymer (CFRP) laminates to strengthen the compression flange of structural I-beam so as to avoid local failure of compression flange and to take a load to its full capacity. Light weight beam (LB) 100 at 5.1 kg/m and LB 115 at 8.1 kg/m are used for this purpose. The compression flange of a beam is well prepared to ensure a rust-free surface so as to achieve proper bonding between the flange and fiber sheet to avoid de-bonding at the time of testing. A flange of the beam is strengthened using CFRP sheets applied to it with the help of adhesive. The beam with CFRP is cured in air for 48 h before testing. Experiments are performed in a loading frame of 100 T capacity. Results show that the load carrying capacity of the strengthened beam increased by 25-30 per cent compared to the control beam (non-strengthened), and the local failure of the compression flange due to the applied load is totally avoided. The elastic behavior of the strengthened beam is also increased compared to the non-strengthened beam, which gives a higher yield point.

Design/methodology/approach

Different methods exist for strengthening various structures. Use of CFRP appears to be an excellent solution. Vast research has been conducted on the use of CFRP for strengthening and retrofitting of steel structures. The load carrying capacities of steel beams can be increased by strengthening their compression flange by using CFRP and avoiding the local failure of beams at early stages.

Findings

The load carrying capacity of a beam strengthened with CFRP increased by 25-30 per cent compared to the non-strengthened beam. In addition, the elastic behavior of the strengthened beam is also improved.

Originality/value

The compression flange of the steel beam is strengthened using different layers of CFRP strips to avoid the local failure, and its deflection is observed using linear variable deformation transducer.

Details

Journal of Engineering, Design and Technology, vol. 17 no. 4
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 1 May 2002

R.V. Balendran, T.M. Rana, T. Maqsood and W.C. Tang

This paper presents an overview and discusses the applications of fibre reinforced polymer (FRP) bars as reinforcement in civil engineering structures. Following a discussion of…

3777

Abstract

This paper presents an overview and discusses the applications of fibre reinforced polymer (FRP) bars as reinforcement in civil engineering structures. Following a discussion of the science underpinning their use, selected case studies where FRP reinforcement has been used are presented. The use of FRP reinforcement is rapidly gaining pace and may replace the traditional steel due to its enhanced properties and cost‐effectiveness. In addition, FRP reinforcement offers an effective solution to the problem of steel durability in aggressive environments and where the magnetic or electrical properties of steel are undesirable.

Details

Structural Survey, vol. 20 no. 2
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 7 September 2022

Paulo Silva Lobo, Mariana Jesus and Paulo S.A. Freitas

In this paper a model for the prediction of the failure strain of fiber reinforced polymer (FRP) sheets is proposed, based on a significant database consisting of results reported…

Abstract

Purpose

In this paper a model for the prediction of the failure strain of fiber reinforced polymer (FRP) sheets is proposed, based on a significant database consisting of results reported in the literature for concrete columns with circular cross-section confined with carbon, glass and aramid fiber reinforced polymers. This study aims to analyze the aforementioned model.

Design/methodology/approach

Significant experimental research on the confinement of columns externally wrapped with FRP has been carried out in the last decades. Several models of confined concrete have been proposed using different approaches for the prediction of the failure strain of FRP sheets. The majority of those proposals were developed to be simple, thus significant differences with experimental results can be found.

Findings

The results of a total of 572 specimens were considered. Statistical analysis was used to derive a regression model, which relates the outcome to a set of predictors of interest using linear assumptions.

Originality/value

The proposed model is shown to be more accurate than other proposals found in the literature.

Details

International Journal of Structural Integrity, vol. 14 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 27 July 2021

Mervin Ealiyas Mathews, Anand N, Diana Andrushia A, Tattukolla Kiran and Khalifa Al-Jabri

Building elements that are damaged by fire are often strengthened by fiber wrapping techniques. Self-compacting concrete (SCC) is an advanced building material that is widely used…

Abstract

Purpose

Building elements that are damaged by fire are often strengthened by fiber wrapping techniques. Self-compacting concrete (SCC) is an advanced building material that is widely used in construction due to its ability to flow and pass through congested reinforcement and fill the required areas easily without compaction. The aim of the research work is to examine the flexural behavior of SCC subjected to elevated temperature. This research work examines the effect of natural air cooling (AC) and water cooling (WC) on flexural behavior of M20, M30, M40 and M50 grade fire-affected retro-fitted SCC. The results of the investigation will enable the designers to choose the appropriate repair technique for improving the service life of structures.

Design/methodology/approach

In this study, an attempt has been made to evaluate the flexural behavior of fire exposed reinforced SCC beams retrofitted with laminates of carbon fiber reinforced polymer (CFRP), basalt fiber reinforced polymer (BFRP) and glass fiber reinforced polymer (GFRP). Beam specimens were cast with M20, M30, M40 and M50 grades of SCC and heated to 925ºC using an electrical furnace for 60 min duration following ISO 834 standard fire curve. The heated SCC beams were cooled by either natural air or water spraying.

Findings

The reduction in the ultimate load carrying capacity of heated beams was about 42% and 55% for M50 grade specimens that were cooled by air and water, respectively, in comparison with the reference specimens. The increase in the ultimate load was 54%, 38% and 27% for the specimens retrofitted with CFRP, BFRP and GFRP, respectively, compared with the fire-affected specimens cooled by natural air. Water-cooled specimens had shown higher level of damage than the air-cooled specimens. The specimens wrapped with carbon fiber could able to improve the flexural strength than basalt and glass fiber wrapping.

Originality/value

SCC, being a high performance concrete, is essential to evaluate the performance under fire conditions. This research work provides the flexural behavior and physical characteristics of SCC subjected to elevated temperature as per ISO rate of heating. In addition attempt has been made to enhance the flexural strength of fire-exposed SCC with wrapping using different fibers. The experimental data will enable the engineers to choose the appropriate material for retrofitting.

Details

Journal of Structural Fire Engineering, vol. 12 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 10 October 2020

Sabiha Barour and Abdesselam Zergua

This paper aims to analyze the performance of reinforced concrete (RC) beams strengthened in shear with carbon fiber-reinforced polymer (CFRP) sheets subjected to four-point…

Abstract

Purpose

This paper aims to analyze the performance of reinforced concrete (RC) beams strengthened in shear with carbon fiber-reinforced polymer (CFRP) sheets subjected to four-point bending.

Design/methodology/approach

ANSYS software is used to build six models. In addition, SOILD65, LINK180, SHELL181 and SOLID185 elements are used, respectively, to model concrete, steel reinforcement, polymer and steel plate support. A comparative study between the nonlinear finite element and analytical models, including the ACI 440.2 R-08 and FIB14 models as well as experimental data, is also carried out.

Findings

The comparative study of the nonlinear finite element results with analytical models shows that the difference between the predicted load capacity ranges from 4.44%–24.49% in the case of the ACI 440.2 R-08 model, while the difference for FIB14 code ranges from 2.69%–26.03%. It is clear that there is a good agreement between the nonlinear finite element analysis (NLFEA) results and the different expected CFRP codes.

Practical implications

This model can be used to explore the behavior and predict the RC beams strengthened in shear with different CFRP properties. They could be used as a numerical platform in contrast to expensive and time-consuming experimental tests.

Originality/value

On the basis of the results, a good match is found between the model results and the experimental data at all stages of loading the tested samples. Load capacities as well as load deflection curves are also presented. It is concluded that the differences between the loads at failure ranged from 0.09%–6.16% and 0.56%–4.98%, comparing with experimental study. In addition, the increase in compressive strength produces an increase in the ultimate load capacity of the beam. The difference in the ultimate load capacity was less than 30% when compared with the American Concrete Institute and FIB14 codes.

Details

Journal of Engineering, Design and Technology , vol. 19 no. 2
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 9 January 2024

Yunfei Zou

This study aims to enhance the understanding of fiber-reinforced polymer (FRP) applications in partially confined concrete, with a specific focus on improving economic value and…

Abstract

Purpose

This study aims to enhance the understanding of fiber-reinforced polymer (FRP) applications in partially confined concrete, with a specific focus on improving economic value and load-bearing capacity. The research addresses the need for a more comprehensive analysis of non-uniform vertical strain responses and precise stress–strain models for FRP partially confined concrete.

Design/methodology/approach

DIC and strain gauges were employed to gather data during axial compression tests on FRP partially confined concrete specimens. Finite element analysis using ABAQUS was utilized to model partial confinement concrete with various constraint area ratios, ranging from 0 to 1. Experimental findings and simulation results were compared to refine and validate the stress–strain model.

Findings

The experimental results revealed that specimens exhibited strain responses characterized by either hardening or softening in both vertical and horizontal directions. The finite element analysis accurately reflected the relationship between surface constraint forces and axial strains in the x, y and z axes under different constraint area ratios. A proposed stress–strain model demonstrated high predictive accuracy for FRP partially confined concrete columns.

Practical implications

The stress–strain curves of partially confined concrete, based on Teng's foundation model for fully confined stress–strain behavior, exhibit a high level of predictive accuracy. These findings enhance the understanding of the mechanical behavior of partially confined concrete specimens, which is crucial for designing and assessing FRP confined concrete structures.

Originality/value

This research introduces innovative insights into the superior convenience and efficiency of partial wrapping strategies in the rehabilitation of beam-column joints, surpassing traditional full confinement methods. The study contributes methodological innovation by refining stress–strain models specifically for partially confined concrete, addressing the limitations of existing models. The combination of experimental and simulated assessments using DIC and FEM technologies provides robust empirical evidence, advancing the understanding and optimization of FRP-concrete structure performance. This work holds significance for the broader field of concrete structure reinforcement.

Details

International Journal of Structural Integrity, vol. 15 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 14 June 2019

Abdurra’uf M. Gora, Jayaprakash Jaganathan, M.P. Anwar and H.Y. Leung

Advanced fibre-reinforced polymer (FRP) composites have been increasingly used over the past two decades for strengthening, upgrading and restoring degraded civil engineering…

Abstract

Purpose

Advanced fibre-reinforced polymer (FRP) composites have been increasingly used over the past two decades for strengthening, upgrading and restoring degraded civil engineering infrastructure. Substantial experimental investigations have been conducted in recent years to understand the compressive behaviour of FRP-confined concrete columns. A considerable number of confinement models to predict the compressive behaviour of FRP-strengthened concrete columns have been developed from the results of these experimental investigations. The purpose of this paper is to present a comprehensive review of experimental investigations and theoretical models of circular and non-circular concrete columns confined with FRP reinforcement.

Design/methodology/approach

The paper reviews previous experimental test results on circular and non-circular concrete columns confined with FRP reinforcement under concentric and eccentric loading conditions and highlights the behaviour and mechanics of FRP confinement in these columns. The paper also reviews existing confinement models for concrete columns confined with FRP composites in both circular and non-circular sections.

Findings

This paper demonstrates that the performance and effectiveness of FRP confinement in concrete columns have been extensively investigated and proven effective in enhancing the structural performance and ductility of strengthened columns. The strength and ductility enhancement depend on the number of FRP layers, concrete compressive strength, corner radius for non-circular columns and intensity of load eccentricity for eccentrically loaded columns. The impact of existing theoretical models and directions for future research are also presented.

Originality/value

Potential researchers will gain insight into existing experimental and theoretical studies and future research directions.

Details

World Journal of Engineering, vol. 16 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 1 December 2002

H.Y. Leung

This paper aims to study the effect of external glass fibre reinforced polymer (GFRP) plates on the flexural and shear behaviour of structurally deficient reinforced concrete (RC…

Abstract

This paper aims to study the effect of external glass fibre reinforced polymer (GFRP) plates on the flexural and shear behaviour of structurally deficient reinforced concrete (RC) beams, a total of ten 180mm×250mm×2,500mm beams, including over‐designed, unplated under‐designed and plated under‐designed, were tested under four‐point bending condition. Experimental results indicate that the use of GFRP plates enhances the strength and deformation capacity of RC beams by altering their failure modes. Application of side plates on shear‐deficient RC beams appears to be more effective than using bottom plates on flexure‐deficient RC beams. However, without any improvement of concrete compressive capacity, additional shear capacities provided to the beams under the action of side plates increase the likelihood of beam failure by concrete crushing. Simultaneous use of bottom and side plates on flexural‐ and shear‐deficient RC beams may result in reduced deflection.

Details

Structural Survey, vol. 20 no. 5
Type: Research Article
ISSN: 0263-080X

Keywords

1 – 10 of 243