Search results

1 – 6 of 6
Article
Publication date: 9 May 2023

Zhuangsu Kang, Zongxing Zhang, Shenyou Song, Qian Cheng, Siyu Tao and Ya Ni

This paper aims to investigate the effect of characteristic parameters of pits on the mechanical properties and fracture model of cable steel wires.

Abstract

Purpose

This paper aims to investigate the effect of characteristic parameters of pits on the mechanical properties and fracture model of cable steel wires.

Design/methodology/approach

The tensile test and finite element analysis of steel wires with corrosion damage were carried out. The stress development of corroded steel wire under corrosion morphology was studied by the 3D reverse reconstruction technology. The internal relationship between the stress triaxiality, equivalent plastic strain and pit depth, depth-width ratio of corroded steel wire was discussed.

Findings

With the increase of corrosion degree, the neck shrinkage phenomenon of steel wire was not significant, and the crack originated near the pit bottom and expanded to the section inside of specimen. The fiber area of corroded steel wire decreased while the radiation area increased, and the ductile fracture gradually changed to brittle fracture. The pit size significantly changed the triaxial degree and distribution of stress and accelerated the initiation and propagation of internal cracks at the neck shrinkage stage.

Originality/value

The proposed fracture model based on the void growth model could accurately simulate the fracture behavior of steel wires with corrosion damage.

Details

Anti-Corrosion Methods and Materials, vol. 70 no. 4
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 13 June 2023

Mohammad Farhan Shaikh and Nallasivam K

In this study, a finite element model of a box-girder bridge along with the railway sub-track system is developed to predict the static behavior due to different combinations of…

83

Abstract

Purpose

In this study, a finite element model of a box-girder bridge along with the railway sub-track system is developed to predict the static behavior due to different combinations of the Indian railway system and free vibration responses resulting in different natural frequencies and their corresponding mode shapes.

Design/methodology/approach

The modeling and evaluation of the bridge and sub-track system were performed using non-closed form finite element method (FEM)-based ANSYS software.

Findings

From the analysis, the worst possible cases of deformation and stress due to different static load combinations were determined in the static analysis, while different natural frequencies were determined in the free vibrational analysis that can be used for further analysis because of the dynamic effect of the train vehicle.

Research limitations/implications

The scope of the current investigation is confined to the structure's static and free vibration analysis. However, this study will help the designers obtain relevant information for further analysis of the dynamic behavior of the bridge model.

Originality/value

In static analysis, the maximum deformation of the bridge deck was found to be 10.70E-03m due to load combination 5, whereas the maximum natural frequency for free vibration analysis is found to be 4.7626 Hz.

Details

Multidiscipline Modeling in Materials and Structures, vol. 19 no. 5
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 30 May 2023

Yan Liang, Yingying Wei, Panjie Li, Liangliang Li and Zhenghao Zhao

For coastal bridges, the ability to recover traffic functions after the earthquake has crucial implications for post-disaster reconstruction, which makes resilience become a…

Abstract

Purpose

For coastal bridges, the ability to recover traffic functions after the earthquake has crucial implications for post-disaster reconstruction, which makes resilience become a significant index to evaluate the seismic behavior. However, the deterioration of the material is particularly prominent in coastal bridge, which causes the degradation of the seismic behavior. As far, the research studies on resilience of coastal bridges considering multiple degradation factors and different disaster prevention capability are scarce. For further evaluating the seismic behavior of coastal bridge in the long-term context, the seismic resilience is conducted in this paper with considering multiple durability damage.

Design/methodology/approach

The fuzzy theory and time-varying fragility analysis are combined in this paper to obtain the life-cycle resilience of coastal bridges.

Findings

The results show that durability damage has a remarkable impact on the resilience. After 100 years of service, the seismic resilience of bridge with poor disaster-prevention capability has greatest reduction, about 18%. In addition, the improvement of the disaster prevention capability can stabilize the resilience of the bridge at a higher level.

Originality/value

In this paper, the time-varying fragility analysis of case bridge are evaluated with considering chloride ion erosion and concrete carbonization, firstly. Then, combining fuzzy theory and fragility analysis, the triangular fuzzy values of resilience parameters under different service period are obtained. Finally, the life-cycle resilience of bridge in different disaster prevention capability is analyzed.

Details

International Journal of Structural Integrity, vol. 14 no. 4
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 4 September 2023

Xuanzhi Li, Suduo Xue, Xiongyan Li, Guanchen Liu and Renjie Liu

Instantaneous unloading with equal force is usually used to simulate the sudden failure of cables. This simulation method with equivalent force requires obtaining the magnitude…

Abstract

Purpose

Instantaneous unloading with equal force is usually used to simulate the sudden failure of cables. This simulation method with equivalent force requires obtaining the magnitude and direction of the force for the failed cable in the normal state. It is difficult, however, to determine the magnitude or direction of the equivalent force when the shape of the cable is complex (space curve). This model of equivalent force may be difficult to establish. Thus, a numerical simulation method, the instantaneous temperature rise method, was proposed to address the dynamic response caused by failures of the cables with complex structural form.

Design/methodology/approach

This method can instantly reduce the cable force to zero through the instantaneous temperature rise process of the cable. Combined with theoretical formula and finite element model, the numerical calculation principle and two key parameters (temperature rise value and temperature rise time) of this method were detailed. The validity of this approach was verified by comparing it with equivalent force models. Two cable-net case with saddle curved surfaces were presented. Their static failure behaviors were compared with the dynamic failure behaviors calculated by this method.

Findings

This simulation method can effectively address the structural dynamic response caused by cable failure and may be applied to all cable structures.

Originality/value

An instantaneous temperature rise method (ITRM) is proposed and verified. Its calculation theory is detailed. Two key parameters, temperature rise value and temperature rise time, of this method are discussed and the corresponding reference values are recommended.

Details

Engineering Computations, vol. 40 no. 9/10
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 4 August 2023

Zhiqi Liu, Tanghong Liu, Hongrui Gao, Houyu Gu, Yutao Xia and Bin Xu

Constructing porous wind barriers is one of the most effective approaches to increase the running safety of trains on viaducts in crosswinds. This paper aims to further improve…

Abstract

Purpose

Constructing porous wind barriers is one of the most effective approaches to increase the running safety of trains on viaducts in crosswinds. This paper aims to further improve the wind-sheltering performance of the porous wind barriers.

Design/methodology/approach

Improved delayed detached eddy simulations based on the k-ω turbulence model were carried out, and the results were validated with wind tunnel tests. The effects of the hole diameter on the flow characteristics and wind-sheltering performance were studied by comparing the wind barriers with the porosity of 21.6% and the hole diameters of 60 mm–360 mm. The flow characteristics above the windward and leeward tracks were analyzed, and the wind-sheltering performance of the wind barriers was assessed using the wind speed reduction coefficients.

Findings

The hole diameters affected the jet behind the wind barriers and the recirculation region above the tracks. Below the top of the wind barriers, the time-averaged velocity first decreased and then increased with the increase in the hole diameter. The wind barrier with the hole diameter of 120 mm had the best wind-sheltering performance for the windward track, but such barrier might lead to overprotection on the leeward track. The wind-sheltering performance of the wind barriers with the hole diameters of 240 mm and 360 mm was significantly degraded, especially above the windward track.

Originality/value

The effects of the hole diameters on the wake and wind-sheltering performance of the wind barriers were studied, by which the theoretical basis is provided for a better design of the porous wind barrier.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 33 no. 11
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 5 June 2023

Takumi Yamaguchi and Fuminobu Ozaki

The main purpose of this study was to evaluate the tensile strengths of JIS G3549 super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope…

41

Abstract

Purpose

The main purpose of this study was to evaluate the tensile strengths of JIS G3549 super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections at fire and post fire.

Design/methodology/approach

Steady-state tests from ambient temperature (20 °C) to 800 °C, transient-state tests under the allowable design tensile force and tensile tests in an ambient temperature environment after heating (heating temperatures of 200–800 °C) were conducted.

Findings

The tensile strengths of the wire rope and end-connection specimens at both fire and post fire were obtained. The steel wire rope specimens possessed larger reduction factors than general hot-rolled mild steels (JIS SS400) and high-strength steel bolts (JIS F10T). The end-connection specimens with sufficient socket lengths exhibited ductile fracture of the wire rope part at both fire and post fire; however, those with short socket lengths experienced a pull-out fracture at the socket.

Originality/value

The fundamental and important tensile test results of the super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections were accumulated at fire and post fire, and the fracture modes were clarified. The obtained test results contribute to fire resistance performance-based design of cable steel structures at fire and fire-damage investigations to consider their reusability post fire.

Access

Year

Last 12 months (6)

Content type