Search results

1 – 10 of 57
Article
Publication date: 25 January 2021

Ying-Ji Chuang and Hsing-Chih Tsai

This paper aims to use a derivative of genetic programming to predict the bond strength of glass fiber-reinforced polymer (GFRP) bars in concrete under the effects of design…

Abstract

Purpose

This paper aims to use a derivative of genetic programming to predict the bond strength of glass fiber-reinforced polymer (GFRP) bars in concrete under the effects of design guidelines. In developing bond strength prediction models, this paper prioritized simplicity and meaningfulness over extreme accuracy.

Design/methodology/approach

Assessing the bond strength of GFRP bars in concrete is a critical issue in designing and building reinforced concrete structures.

Findings

Ultimately, the equation of a linear form of a particular design guideline was suggested as the optimal prediction model. Improvements to the current design guidelines suggested by this model include setting a 1.31 magnification and considering the effects of the three significant parameters of bar diameter (db), minimum cover-to-bar diameter (C/db) and development length to bar diameter (l/db) under an acceptable root mean square error accuracy of around 2 MPa. Furthermore, the model suggests that the original influence parameter of concrete compressive strength (fc) may be removed from bond strength calculations.

Originality/value

The model suggests that the original influence parameter of concrete compressive strength (fc) may be removed from bond strength calculations.

Details

Engineering Computations, vol. 38 no. 5
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 1 May 2002

R.V. Balendran, T.M. Rana, T. Maqsood and W.C. Tang

This paper presents an overview and discusses the applications of fibre reinforced polymer (FRP) bars as reinforcement in civil engineering structures. Following a discussion of

3777

Abstract

This paper presents an overview and discusses the applications of fibre reinforced polymer (FRP) bars as reinforcement in civil engineering structures. Following a discussion of the science underpinning their use, selected case studies where FRP reinforcement has been used are presented. The use of FRP reinforcement is rapidly gaining pace and may replace the traditional steel due to its enhanced properties and cost‐effectiveness. In addition, FRP reinforcement offers an effective solution to the problem of steel durability in aggressive environments and where the magnetic or electrical properties of steel are undesirable.

Details

Structural Survey, vol. 20 no. 2
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 1 July 1995

Y.N. Ziraba, M.H. Baluch, A.M. Sharif, G.J. Al—Sulaimani, A.K. Azad and I.A. Basunbul

This paper presents a finite element model for analysis of damaged RCbeams strengthened or repaired by externally bonding glass fibre reinforcedplastics (GFRP) on the tension side…

Abstract

This paper presents a finite element model for analysis of damaged RC beams strengthened or repaired by externally bonding glass fibre reinforced plastics (GFRP) on the tension side of the beams. The salient features include: (i) the introduction of a thin, six—noded element to simulate behaviour of the concrete/epoxy glue/GFRP interface and )ii( a scheme of loading a virgin RC beam to a prescribed displacement to simulate damage, unloading and then reloading the damaged RC beam fortified by an externally bonded GFRP plate. Results are presented for RC beams repaired by plates of varying thickness and a transmutation of failure mode is noted from classical flexure for the case of external reinforcement in the form of thin GFRP plates to a unique concrete cover rip off failure for thicker GFRP plates and not predicted by the ACI shear strength formula for diagonal tension failure of unplated RC beams of similar geometry.

Details

Engineering Computations, vol. 12 no. 7
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 17 December 2021

Yousef Al Rjoub, Ala Obaidat, Ahmed Ashteyat and Khalid Alshboul

This study aims to conduct an experimental study and finite element model (FEM) to investigate the flexural behavior of heat-damaged beams strengthened/repaired by hybrid…

Abstract

Purpose

This study aims to conduct an experimental study and finite element model (FEM) to investigate the flexural behavior of heat-damaged beams strengthened/repaired by hybrid fiber-reinforced polymers (HFRP).

Design/methodology/approach

Two groups of beams of (150 × 250 × 1,200) mm were cast, strengthened and repaired using different configurations of HFRP and tested under four-point loadings. The first group was kept at room temperature, while the second group was exposed to a temperature of 400°C.

Findings

It was found that using multiple layers of carbon fiber-reinforced polymer (CFRP) and glass fiber-reinforced polymer (GFRP) enhanced the strength more than a single layer. Also, the order of two layers of FRP showed no effect on flexural behavior of beams. Using a three-layer scheme (attaching the GFRP first and followed by two layers of CFRP) exhibited increase in ultimate load more than the scheme attached by CFRP first. Furthermore, the scheme HGC (heated beam repaired with glass and carbon, in sequence) allowed to achieve residual flexural capacity of specimen exposed to 400°C. Typical flexural failure was observed in control and heat-damaged beams, whereas the strengthened/repaired beams failed by cover separation and FRP debonding, however, specimen repaired with two layers of GFRP failed by FRP rupture. The FEM results showed good agreement with experimental results.

Originality/value

Few researchers have studied the effects of HFRP on strengthening and repair of heated, damaged reinforced concrete (RC) beams. This paper investigates, both experimentally and analytically, the performance of externally strengthened and repaired RC beams, in flexure, with different FRP configurations of CFRP and GFRP.

Details

Journal of Structural Fire Engineering, vol. 13 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 October 2003

H.Y. Leung and R.V. Balendran

Use of fibre‐reinforced polymer (FRP) composite rods, in lieu of steel rebars, as the main flexural reinforcements in reinforced concrete (RC) beams have recently been suggested…

2656

Abstract

Use of fibre‐reinforced polymer (FRP) composite rods, in lieu of steel rebars, as the main flexural reinforcements in reinforced concrete (RC) beams have recently been suggested by many researchers. However, the development of FRP RC beam design is still stagnant in the construction industry and this may be attributed to a number of reasons such as the high cost of FRP rods compared to steel rebars and the reduced member ductility due to the brittleness of FRP rods. To resolve these problems, one of the possible methods is to adopt both FRP rods and steel rebars to internally reinforce the concrete members. The effectiveness of this new reinforcing system remains problematic and continued research in this area is needed. An experimental study on the load‐deflection behaviour of concrete beams internally reinforced with glass fibre‐reinforced polymer (GFRP) rods and steel rebars was therefore conducted and some important findings are summarized in this paper.

Details

Structural Survey, vol. 21 no. 4
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 16 December 2021

Bashar Ramzi Behnam and Mohammed M. Mahmood Al-Iessa

The purpose of this paper is to investigate the potential design advantage in terms of resistance factors for normal weight concrete beams containing moderate-dose randomly…

Abstract

Purpose

The purpose of this paper is to investigate the potential design advantage in terms of resistance factors for normal weight concrete beams containing moderate-dose randomly dispersed short fibers and reinforced with glass fiber reinforced polymer (GFRP) bars.

Design/methodology/approach

An analytical model based on the current code specifications is used to calculate the moment capacity of over-reinforced sections. The vast majority of the considered beams are over-reinforced, compression-controlled. The data of the fiber-reinforced concrete (FRC) reinforced with GFRP bars are collected from three published research studies which are based on experimentally tested results. Three different types of short fibers with four volume fractions are considered. Probabilistic model is established to conduct reliability-based calibration using Monte-Carlo Simulation. Limit state function, relevant load and resistance random variables are identified, and adequate statistical parameters are selected. Target reliability index consistent with the one used to develop current design code specifications is used.

Findings

Reliability analysis and calibration process are carried out with the intention of estimating the flexural resistance factors for FRC beams reinforced with GFRP bars.

Originality/value

The predicted flexural resistance factors ranged from 0.72 to 0.95, giving the resistance factors the potential to be increased above the currently specified value of 0.65 for compression-controlled members reinforced with FRP bars.

Details

International Journal of Structural Integrity, vol. 13 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 12 June 2017

Danie Roy Anasco Bastin, Umesh Kumar Sharma and Pradeep Bhargava

The main aim of this research was to investigate the effectiveness of various strengthening techniques in restoring the structural performance of reinforced concrete (RC) beams…

Abstract

Purpose

The main aim of this research was to investigate the effectiveness of various strengthening techniques in restoring the structural performance of reinforced concrete (RC) beams damaged by elevated temperatures.

Design/methodology/approach

Three different strengthening techniques, namely, high-strength fibre reinforced concrete (HSFRC), ferrocement (FC) jacketing and externally bonded fibre-reinforced polymer (FRP) were used. Series of RC beams were casted, heated, strengthened and tested to investigate the influence of various variables. The variables of the study were type of strengthening and level of heat damage.

Findings

Externally bonded FRP was found to be the best among the various techniques, especially with respect to strength and stiffness restoration. On the contrary, the FRP strengthening was not that effective in restoring the energy absorption capacity of beams compared to HSFRC and FC techniques of strengthening. The chosen strengthening techniques were able to restore the failure mode of beams to flexural failure, which was found to have changed to shear failure in case of heated unstrenghthened beams.

Originality/value

This research program has contributed to the fundamental understanding of designing post fire retrofit solutions for RC beams.

Details

Journal of Structural Fire Engineering, vol. 8 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 5 April 2011

Alan Richardson and Paula Drew

This paper aims to investigate the necessary requirements that a concrete reinforcement material must satisfy; namely the ability to resist tensile forces and have good bond

1594

Abstract

Purpose

This paper aims to investigate the necessary requirements that a concrete reinforcement material must satisfy; namely the ability to resist tensile forces and have good bond strength while providing structural qualities of toughness and flexural strength.

Design/methodology/approach

The bond and strength properties were mainly tested in a paired comparison test using 6 mm diameter steel and fibre reinforced polymer (FRP) rebar specimens in beams and cubes. Bond strength was examined using 12 concrete cube specimens of 150 mm, six cubes had steel rebar and six had FRP rebar inserted through the full depth of the cube and they were subject to pull out tests. To determine flexural strength and toughness, a three point loading test was performed to provide load/extension data on 28 500×100×100 mm concrete beams. A total of 14 beams were cast with steel rebar and 14 were cast with FRP rebar.

Findings

The results showed for equal diameter bars the FRP specimens had outperformed steel in each test. Failure modes of FRP specimens showed higher degrees of toughness when compared to steel.

Originality/value

Steel rebar has a long and proven track record of satisfactory use in reinforced concrete. For designers and clients to change from traditionally used materials, there is a need for investigative research to prove the worth of the new material. This paper goes part of the way to fulfil this need.

Details

Structural Survey, vol. 29 no. 1
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 14 July 2021

Sachin B.P. and N. Suresh

The purpose of the paper is to study the effect of elevated temperature on load carrying capacity of reinforced self compacting concrete beams and the performance of deteriorated…

Abstract

Purpose

The purpose of the paper is to study the effect of elevated temperature on load carrying capacity of reinforced self compacting concrete beams and the performance of deteriorated beams after retrofitting by GFRP sheets. The reinforced beams which were exposed to sustained elevated temperature and tested for flexural load-carrying capacity. Further deteriorated beams (exposed from 500°C to 800°C) were re-strengthened by adopting retrofitting with GFRP sheets.

Design/methodology/approach

The investigation includes the concrete specimens, i.e. cubes of 150 mm, cylinders of size 150 mm dia with 300 mm height and beams of 150 × 150 × 1,100 mm, reinforced with minimum tension reinforcement according to IS 456–2000. The specimens were subjected to elevated temperature from 300°C to 800°C with an interval of 100°C for 2 h. The residual compressive strength, modulus of elasticity, load at first crack of beams and load-carrying capacity of beams for 5-mm deflection were measured before and after retrofitting.

Findings

The result shows that there is a gain in residual compressive strength at 300°C and beyond which it decreases. The modulus of elasticity, load at first crack and load-carrying capacity of beams reduces continuously with an increase in temperature. The decrease in load-carrying capacity of beams is observed from 27.55% and up to 38.77% between the temperature range of 500°C–800°C and after the retrofitting of distressed beams, the load carrying capacity increases up to 24.48%.

Originality/value

Better performance was observed with retrofitting by GFRP sheets when the specimens were distressed due to elevated temperatures.

Details

Journal of Structural Fire Engineering, vol. 12 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 December 2002

H.Y. Leung

This paper aims to study the effect of external glass fibre reinforced polymer (GFRP) plates on the flexural and shear behaviour of structurally deficient reinforced concrete (RC…

Abstract

This paper aims to study the effect of external glass fibre reinforced polymer (GFRP) plates on the flexural and shear behaviour of structurally deficient reinforced concrete (RC) beams, a total of ten 180mm×250mm×2,500mm beams, including over‐designed, unplated under‐designed and plated under‐designed, were tested under four‐point bending condition. Experimental results indicate that the use of GFRP plates enhances the strength and deformation capacity of RC beams by altering their failure modes. Application of side plates on shear‐deficient RC beams appears to be more effective than using bottom plates on flexure‐deficient RC beams. However, without any improvement of concrete compressive capacity, additional shear capacities provided to the beams under the action of side plates increase the likelihood of beam failure by concrete crushing. Simultaneous use of bottom and side plates on flexural‐ and shear‐deficient RC beams may result in reduced deflection.

Details

Structural Survey, vol. 20 no. 5
Type: Research Article
ISSN: 0263-080X

Keywords

1 – 10 of 57