Search results

1 – 10 of 591
Article
Publication date: 1 April 1992

JAROSLAV MACKERLE

This bibliography is offered as a practical guide to published papers, conference proceedings papers and theses/dissertations on the finite element (FE) and boundary element (BE…

Abstract

This bibliography is offered as a practical guide to published papers, conference proceedings papers and theses/dissertations on the finite element (FE) and boundary element (BE) applications in different fields of biomechanics between 1976 and 1991. The aim of this paper is to help the users of FE and BE techniques to get better value from a large collection of papers on the subjects. Categories in biomechanics included in this survey are: orthopaedic mechanics, dental mechanics, cardiovascular mechanics, soft tissue mechanics, biological flow, impact injury, and other fields of applications. More than 900 references are listed.

Details

Engineering Computations, vol. 9 no. 4
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 23 October 2017

Elnaz Afshari, Hadi Sarkhosh and Siamak Najarian

The paper aims to discuss design, fabrication, testing and simulation of a novel tactile probe used for measuring the stiffness of biological soft tissues/materials with a view to…

Abstract

Purpose

The paper aims to discuss design, fabrication, testing and simulation of a novel tactile probe used for measuring the stiffness of biological soft tissues/materials with a view to medical and surgical applications.

Design/methodology/approach

Both finite element modeling and experimental approach were used in this research. The novel tactile probe capable of recording force-deformation feedback is accompanied with the tactile-status-display which is a custom-designed user-friendly interface. This system can evaluate the stiffness in each part of force-deformation status.

Findings

The new system named novel tactile probe was fabricated, and the results on artificial materials (with different stiffnesses) and the sheep kidney (containing a hard object) were reported. Recording different stiffnesses, detecting hard object embedded in soft tissue and predicting the exact location of it are the main results that have been extracted through the diagrams obtained by the novel tactile probe system.

Research limitations/implications

The designed and fabricated system can be modified and miniaturized to be used during different minimally invasive surgeries in the future.

Practical implications

The most distinguishing feature of this novel tactile probe is its applicability during different laparoscopic surgeries, so the in vivo data can be obtained.

Originality/value

For the first time, a tactile probe has been designed and tested in the form of laparoscopic instrument which upgrades the efficiency of available laparoscopic instruments. Also, the novel tactile probe can be used in both in vivo and in vitro experimental setups for measuring the stiffness of sensed objects.

Details

Sensor Review, vol. 37 no. 4
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 18 September 2007

Hamid Roham, Siamak Najarian, Seyed Mohsen Hosseini and Javad Dargahi

The paper aims to discuss the design, fabrication, communication, testing, and simulation of a new tactile probe called Elastirob used to measure the modulus of elasticity of…

Abstract

Purpose

The paper aims to discuss the design, fabrication, communication, testing, and simulation of a new tactile probe called Elastirob used to measure the modulus of elasticity of biological soft tissues and soft materials.

Design/methodology/approach

Both finite element modeling and experimental approaches were used in this analysis. Elastirob, with the ability to apply different rates of strain on testing specimens, is accompanied by a tactile display called TacPlay. This display is a custom‐designed user‐friendly interface and is able to evaluate the elasticity in each part of the stress‐strain curve.

Findings

A new device is being constructed that can measure the modulus of elasticity of a sensed object. The results of Elastirob applied on two specimens are reported and compared by the results of experiments obtained by an industrial testing machine. Acceptable validations of Elastirob were achieved from the comparisons.

Research limitations/implications

The designed system can be miniaturized to be used in minimally invasive surgeries in the future.

Practical implications

Elastirob determines the elasticity by drawing the stress‐strain curve and then calculating its slope. The combination of the force sensing resistor, microcontroller and stepper motor provides Elastirob with the ability to apply different rates of strain on testing specimens.

Originality/value

It can be employed in both in vivo and in vitro tests for measuring stiffness of touch objects. For the first time, a device has been designed and tested which is a few orders of magnitude smaller than its industrial counterparts and has considerably lower weight.

Details

Sensor Review, vol. 27 no. 4
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 24 September 2010

M. Grujicic, G. Arakere and T. He

This paper aims to conduct a combined Eulerian/Lagrangian fluid/solid transient non‐linear dynamics computational analysis of the interaction between a single planar blast wave…

1192

Abstract

Purpose

This paper aims to conduct a combined Eulerian/Lagrangian fluid/solid transient non‐linear dynamics computational analysis of the interaction between a single planar blast wave and a human head in order to assess the extent of intra‐cranial shock wave generation and its potential for causing traumatic brain injury.

Design/methodology/approach

Two levels of blast peak overpressure were selected, one corresponding to the unprotected lung‐injury threshold while the other associated with a 50 percent probability for lung injury caused death. Collision of the head with a stationary/rigid barrier (at an initial collision velocity of 5 m/s) was also analyzed computationally, since blunt‐object impact conditions may lead to mild traumatic brain injury (mTBI), i.e. concussion.

Findings

A comparison between the two blast and the single blunt‐object impact cases with the corresponding head‐to‐head‐collision results showed that, while the von Mises stress‐based head‐to‐head collision mTBI thresholds are not exceeded under blast‐loading conditions investigated, the high blast‐induced peak‐pressure levels within the intra‐cranial cavity may lead to mTBI.

Practical implications

While concussion is not generally considered as life altering/threatening, the associated temporary loss of situational awareness or consciousness may have devastating consequences in the case of common military tactical and battle‐field scenarios. This suggests that the head‐protection gear (primarily, the helmet) which are currently designed to withstand blunt‐object and ballistic impacts, should be redesigned in order to obtain the necessary level of head protection with respect to blast impact.

Originality/value

The paper provides a comprehensive computational investigation of impact on a human skull/brain assembly.

Details

Multidiscipline Modeling in Materials and Structures, vol. 6 no. 3
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 6 March 2017

Marek Paruch

The purpose of this study is to show that the methods of the numerical simulation can be a very effective tool for a proper choice of control parameters of artificial…

Abstract

Purpose

The purpose of this study is to show that the methods of the numerical simulation can be a very effective tool for a proper choice of control parameters of artificial hyperthermia. An electromagnetic field induced by two external electrodes and a temperature field resulting from electrodes action in a 3D domain of biological tissue is considered. An important problem is the appropriate directing of heat in the region of tumor, so as to avoid damaging healthy cells surrounding the tumor. Recently, to concentrate the heat on the tumor, magnetic nanoparticles, which are introduced into the tumor, were used. The nanoparticles should be made of material that ensures appropriate magnetic properties and has a high biocompatibility with the biological tissue. External electric field causes the heat generation in the tissue domain.

Design/methodology/approach

The distribution of electric potential in the domain considered is described by the Laplace system of equations, while the temperature field is described by the Pennes’ system of equations. These problems are coupled by source function being the additional component in the Pennes’ equation and resulting from the electric field action. The boundary element method is applied to solve the coupled problem connected with the heating of biological tissues.

Findings

The aim of investigations is to determine an electric potential of external electrodes and the number of nanoparticles introduced to a tumor region to obtain the artificial hyperthermia state. The tests performed showed that the proposed tool to solve the inverse problem provides correct results.

Research limitations/implications

In the paper the steady state bioheat transfer problem is considered, so the thermal damage is a function of the temperature only. Therefore, the solution can be considered as the maximum ablation zone of cancer. Additionally, the choice of appropriate parameters will be affected on the position and shape of the tumor and the electrodes.

Originality/value

In the paper the inverse problem has been solved using the evolutionary algorithm, gradient method and hybrid algorithm which is a combination of the two previous.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 27 no. 3
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 1 March 2005

Qing‐Sheng Yang, Cai‐Qin Cui and Xu‐Zhi Lu

The advanced synthetic and natural materials, such as piezoelectric ceramics, electroactive polymers and biological soft tissues, exhibit the multi‐physical or physicochemical…

Abstract

The advanced synthetic and natural materials, such as piezoelectric ceramics, electroactive polymers and biological soft tissues, exhibit the multi‐physical or physicochemical coupling behaviors. The coupling behavior involves the thermal‐mechanical, electric‐mechanical and electrochemicalmechanical interactions. The coupling phenomena can be modeled in the microscopic and macroscopic levels. In the microscale, the material consists of the solid, fluid and ions. The domain FE technique can be used to model the deformation of the solid and the flow of the fluid. In the macroscale, the mixture theory can be applied to description of the coupled response of the continuum under coupled thermal, electrical, chemical and mechanical loadings. A weak form of the governing equations is established by means of variational principle and a multi‐field finite element (MFE) method is developed for numerical modeling of the coupling behavior of advanced materials.

Details

Multidiscipline Modeling in Materials and Structures, vol. 1 no. 3
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 15 November 2011

Jarraya Abdessalem, Imen Kammoun Kallel and Dammak Fakhreddine

The purpose of this paper is to describe a general theoretical and finite element implementation framework for the constitutive modelling of biological soft tissues.

Abstract

Purpose

The purpose of this paper is to describe a general theoretical and finite element implementation framework for the constitutive modelling of biological soft tissues.

Design/methodology/approach

The model is based on continuum fibers reinforced composites in finite strains. As an extension of the isotropic hyperelasticity, it is assumed that the strain energy function is decomposed into a fully isotropic component and an anisotropic component. Closed form expressions of the stress tensor and elasticity tensor are first established in the general case of fully incompressible plane stress which orthotropic and transversely isotropic hyperelasticity. The incompressibility is satisfied exactly.

Findings

Numerical examples are presented to illustrate the model's performance.

Originality/value

The paper presents a constitutive model for incompressible plane stress transversely isotropic and orthotropic hyperelastic materials.

Details

Multidiscipline Modeling in Materials and Structures, vol. 7 no. 4
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 29 March 2022

Saeed Hatefi Ardakani, Peyman Fatemi Dehaghani, Hesam Moslemzadeh and Soheil Mohammadi

The purpose is to analyze the mechanical behavior of the arterial wall in the degraded region of the arterial wall and to determine the stress distribution, as an important factor…

Abstract

Purpose

The purpose is to analyze the mechanical behavior of the arterial wall in the degraded region of the arterial wall and to determine the stress distribution, as an important factor for predicting the potential failure mechanisms in the wall. In fact, while the collagen fiber degradation process itself is not modeled, zones with reduced collagen fiber content (corresponding to the degradation process) are assumed. To do so, a local weakness in the media layer is considered by defining representative volume elements (RVEs) with different fiber collagen contents in the degraded area to investigate the mechanical response of the arterial wall.

Design/methodology/approach

A three-dimensional (3D) large strain hierarchical multiscale technique, based on the homogenization and genetic algorithm (GA), is utilized to numerically model collagen fiber degradation in a typical artery. Determination of material constants for the ground matrix and collagen fibers in the microscale level is performed by the GA. In order to investigate the mechanical degradation, two types of RVEs with different collagen contents in fibers are considered. Each RVE is divided into two parts of noncollagenous matrix and collagen fiber, and the part of collagen fiber is further divided into matrix and collagen fibrils.

Findings

The von Mises stress distributions on the inner and outer surfaces of the artery and the influence of collagen fiber degradation on thinning of the arterial wall in the degraded area are thoroughly studied. Comparing the maximum stress values on outer and inner surfaces in the degraded region shows that the inner surface is under higher stress states, which makes it more prone to failure. Furthermore, due to the weakness of the artery in the degraded area, it is concluded that the collagen fiber degradation considerably reduces the wall thickness in the degraded area, leading to an observable local inflation across the degraded artery.

Originality/value

Considering that little attention has been paid to multiscale numerical modeling of collagen fiber degradation, in this paper a 3D large strain hierarchical multiscale technique based on homogenization and GA methods is presented. Therefore, while the collagen fiber degradation process itself is not modeled in this study, zones with reduced collagen fiber content (corresponding to the degradation process) are assumed.

Details

Engineering Computations, vol. 39 no. 6
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 30 October 2018

Farita Tasnim, Atieh Sadraei, Bianca Datta, Mina Khan, Kyung Yun Choi, Atharva Sahasrabudhe, Tomás Alfonso Vega Gálvez, Irmandy Wicaksono, Oscar Rosello, Carlos Nunez-Lopez and Canan Dagdeviren

When wearable and implantable devices first arose in the 1970s, they were rigid and clashed dramatically with our soft, pliable skin and organs. The past two decades have…

Abstract

Purpose

When wearable and implantable devices first arose in the 1970s, they were rigid and clashed dramatically with our soft, pliable skin and organs. The past two decades have witnessed a major upheaval in these devices. Traditional electronics are six orders of magnitude stiffer than soft tissue. As a result, when rigid electronics are integrated with the human body, severe challenges in both mechanical and geometrical form mismatch occur. This mismatch creates an uneven contact at the interface of soft-tissue, leading to noisy and unreliable data gathering of the body’s vital signs. This paper aims to predict the role that discreet, seamless medical devices will play in personalized health care by discussing novel solutions for alleviating this interface mismatch and exploring the challenges in developing and commercializing such devices.

Design methodology/approach

Since the form factors of biology cannot be changed to match those of rigid devices, conformable devices that mimic the shape and mechanical properties of soft body tissue must be designed and fabricated. These conformable devices play the role of imperceptible medical interfaces. Such interfaces can help scientists and medical practitioners to gain further insights into the body by providing an accurate and reliable instrument that can conform closely to the target areas of interest for continuous, long-term monitoring of the human body, while improving user experience.

Findings

The authors have highlighted current attempts of mechanically adaptive devices for health care, and the authors forecast key aspects for the future of these conformable biomedical devices and the ways in which these devices will revolutionize how health care is administered or obtained.

Originality/value

The authors conclude this paper with the perspective on the challenges of implementing this technology for practical use, including device packaging, environmental life cycle, data privacy, industry partnership and collaboration.

Details

foresight, vol. 20 no. 6
Type: Research Article
ISSN: 1463-6689

Keywords

Article
Publication date: 1 August 2003

R. Contro and P. Vena

This paper aims at showing that the finite element method is the most important numerical tool to analyse bio‐solids or bio‐fluids because of the constitutive complexity and…

1209

Abstract

This paper aims at showing that the finite element method is the most important numerical tool to analyse bio‐solids or bio‐fluids because of the constitutive complexity and unusual clinical input data and requirements involved. These features are absolutely mandatory and modify the mentality of an expert of FEM when he wants to contribute really to the progress of medical practice in their several forms, from biological basis to the surgical assistance. In this context, a clear view of the hierarchic importance of the phenomena involved is necessary to reply correctly to medical operators and to choose the right level of scale. While a scholarly culture of FEM and relative developments have to appeal the attention of biomedical engineers, at the same time their attention mainly is focused on the problem to solve, which must be validated clinically and experimentally. So while convergence remain a typical goal of the analyst, accuracy must be compared with the medical sensitivity. To do this, some physical conditions, less important in other application fields, as the boundary conditions, must be modelled in order to avoid that any model refinement gives unappreciable precision while tends to disregard what a clinician or a surgeon is able to understand and to use in the context of his professional practice. Setting up correct boundary conditions is an emblematic topic because it concerns a typical approach of computational methods applied to biomedical engineering which must consider two separate scale into analysis or a design approach. When a district of the body is to be analysed, the main goal should be to define correctly the subdomain that the district represents with respect to the whole and then to analyse other subdomains inside, at a level more and more micro, as into a system of Chinese boxes. When a medical device is to be designed a systemic view must be acquired. In this paper, we will start from this underlying feature concerning just FEM applications of a knee design carried out by the research staff of the Laboratory of Biological Structure Mechanics. Then other uses of FEM will be described as analysis fragments through problems studied by the authors and referenced in bibliography.

Details

Engineering Computations, vol. 20 no. 5/6
Type: Research Article
ISSN: 0264-4401

Keywords

1 – 10 of 591