Search results

1 – 1 of 1
Open Access
Article
Publication date: 7 June 2021

Xudong He, GuangYi Yang, E. Yang, Moli Zhang, Dan Luo, Jingjian Liu, Chongnan Zhao, Qinhua Chen and Fengying Ran

Based on DNase I and reduced graphene oxide (rGO)-magnetic silicon microspheres (MNPS), a highly sensitive and selective fluorescent probe for the detection of PD-L1 was developed.

Abstract

Purpose

Based on DNase I and reduced graphene oxide (rGO)-magnetic silicon microspheres (MNPS), a highly sensitive and selective fluorescent probe for the detection of PD-L1 was developed.

Design/methodology/approach

Here °C we present a feasibility of biosensor to detection of PD-L1 in lung tumors plasma. In the absence of PD-L1°C the PD-L1 aptamer is absorbed on the surface of graphene oxide modified magnetic nanoparticles °8rGO-MNPS°9 and leading to effective fluorescence quenching. Upon adding PD-L1°C the aptamer sequences could be specifically recognized by PD-L1 and the aptamer/PD-L1 complex is formed°C resulting in the recovery of quenched fluorescence.

Findings

This sensor can detect PD-L1 with a linear range from 100 pg mL−1 to 100 ng mL−1, and a detection limit of 10 pg•m−1 was achieved.

Originality/value

This method provides an easy and sensitive method for the detection of PD-L1 and will be beneficial to the early diagnosis and prognosis of tumors.

Details

Sensor Review, vol. 41 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Access

Only Open Access

Year

Content type

1 – 1 of 1