Search results
1 – 2 of 2Wei Li, Yuxin Huang, Leilei Ji, Lingling Ma and Ramesh Agarwal
The purpose of this study is to explore the transient characteristics of mixed-flow pumps during startup process.
Abstract
Purpose
The purpose of this study is to explore the transient characteristics of mixed-flow pumps during startup process.
Design/methodology/approach
This study uses a full-flow field transient calculation method of mixed-flow pump based on a closed-loop model.
Findings
The findings show the hydraulic losses and internal flow characteristics of the piping system during the start-up process.
Research limitations/implications
Large computational cost.
Practical implications
Improve the accuracy of current numerical simulation results in transient process of mixed-flow pump.
Originality/value
Simplify the setting of boundary conditions in the transient calculation.
Details
Keywords
Su Yong and Gong Wu-Qi
Abnormal vibrations often occur in the liquid oxygen kerosene transmission pipelines of rocket engines, which seriously threaten their safety. Improper handling can result in…
Abstract
Purpose
Abnormal vibrations often occur in the liquid oxygen kerosene transmission pipelines of rocket engines, which seriously threaten their safety. Improper handling can result in failed rocket launches and significant economic losses. Therefore, this paper aims to examine vibrations in transmission pipelines.
Design/methodology/approach
In this study, a three-dimensional high-pressure pipeline model composed of corrugated pipes, multi-section bent pipes, and other auxiliary structures was established. The fluid–solid coupling method was used to analyse vibration characteristics of the pipeline under various external excitations. The simulation results were visualised using MATLAB, and their validity was verified via a thermal test.
Findings
In this study, the vibration mechanism of a complex high-pressure pipeline was examined via a visualisation method. The results showed that the low-frequency vibration of the pipe was caused by fluid self-excited pressure pulsation, whereas the vibration of the engine system caused a high-frequency vibration of the pipeline. The excitation of external pressure pulses did not significantly affect the vibrations of the pipelines. The visualisation results indicated that the severe vibration position of the pipeline thermal test is mainly concentrated between the inlet and outlet and between the two bellows.
Practical implications
The results of this study aid in understanding the causes of abnormal vibrations in rocket engine pipelines.
Originality/value
The causes of different vibration frequencies in the complex pipelines of rocket engines and the propagation characteristics of external vibration excitation were obtained.