Search results

1 – 10 of over 3000
Article
Publication date: 1 April 1977

K.S. ANAND, O.N. ANAND and M.M. SINGH

MODERN heavy‐duty motor oils are almost invariably formulated with detergent‐dispersant type of additives. The types of additive normally employed for this purpose are…

Abstract

MODERN heavy‐duty motor oils are almost invariably formulated with detergent‐dispersant type of additives. The types of additive normally employed for this purpose are organo‐metallic detergent‐dispersants such as metal salts (barium/calcium) of alkyl phenols, petroleum and synthetic sulphonic acids, condensation products of olefins and P2S5, alkyl salicylic acids, etc., on the one hand, and the polymeric ashless types of dispersants such as polymethacrylic esters and N‐substituted long chain alkyl succinimides, on the other. Barium and calcium salts of the petroleum sulphonic acids, however, are by far the most widely used dispersant‐detergent additives. These additives are manufactured from the sodium salts or the sulphonic acids obtained as a by‐product during the sulphonation of mineral oils for the manufacture of white oils and transformer oils. The average molecular weight of the sodium salts is in the range 450—500.

Details

Industrial Lubrication and Tribology, vol. 29 no. 4
Type: Research Article
ISSN: 0036-8792

Article
Publication date: 27 July 2021

Mervin Ealiyas Mathews, Anand N, Diana Andrushia A, Tattukolla Kiran and Khalifa Al-Jabri

Building elements that are damaged by fire are often strengthened by fiber wrapping techniques. Self-compacting concrete (SCC) is an advanced building material that is widely used…

Abstract

Purpose

Building elements that are damaged by fire are often strengthened by fiber wrapping techniques. Self-compacting concrete (SCC) is an advanced building material that is widely used in construction due to its ability to flow and pass through congested reinforcement and fill the required areas easily without compaction. The aim of the research work is to examine the flexural behavior of SCC subjected to elevated temperature. This research work examines the effect of natural air cooling (AC) and water cooling (WC) on flexural behavior of M20, M30, M40 and M50 grade fire-affected retro-fitted SCC. The results of the investigation will enable the designers to choose the appropriate repair technique for improving the service life of structures.

Design/methodology/approach

In this study, an attempt has been made to evaluate the flexural behavior of fire exposed reinforced SCC beams retrofitted with laminates of carbon fiber reinforced polymer (CFRP), basalt fiber reinforced polymer (BFRP) and glass fiber reinforced polymer (GFRP). Beam specimens were cast with M20, M30, M40 and M50 grades of SCC and heated to 925ºC using an electrical furnace for 60 min duration following ISO 834 standard fire curve. The heated SCC beams were cooled by either natural air or water spraying.

Findings

The reduction in the ultimate load carrying capacity of heated beams was about 42% and 55% for M50 grade specimens that were cooled by air and water, respectively, in comparison with the reference specimens. The increase in the ultimate load was 54%, 38% and 27% for the specimens retrofitted with CFRP, BFRP and GFRP, respectively, compared with the fire-affected specimens cooled by natural air. Water-cooled specimens had shown higher level of damage than the air-cooled specimens. The specimens wrapped with carbon fiber could able to improve the flexural strength than basalt and glass fiber wrapping.

Originality/value

SCC, being a high performance concrete, is essential to evaluate the performance under fire conditions. This research work provides the flexural behavior and physical characteristics of SCC subjected to elevated temperature as per ISO rate of heating. In addition attempt has been made to enhance the flexural strength of fire-exposed SCC with wrapping using different fibers. The experimental data will enable the engineers to choose the appropriate material for retrofitting.

Details

Journal of Structural Fire Engineering, vol. 12 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 4 November 2019

Diana Andrushia, N. Anand and Prince Arulraj

Health monitoring of concrete is one of the important tasks in the structural health monitoring. The life of any infrastructure relies on the quality of the concrete. The computer…

Abstract

Purpose

Health monitoring of concrete is one of the important tasks in the structural health monitoring. The life of any infrastructure relies on the quality of the concrete. The computer vision-based methods are very useful to identify the structural defects. The identification of minor cracks in the noisy concrete image is complex. The purpose of this paper is to denoise the concrete crack images and also segment the cracks.

Design/methodology/approach

The novelty of the proposed work lies on the usage of anisotropic diffusion filter in the noisy concrete images. Initially anisotropic diffusion filter is applied to smoothen the concrete images. Adaptive threshold and gray level-based edge stopping constant are used in the diffusion process. The statistical six sigma-based method is utilized to segment the cracks from smoothened concrete images.

Findings

The proposed method is compared with five state-of-the-art-methods with the performance metrics of mean square error, peak signal to noise ratio and mean structural similarity. The experimental results highlight the advantages of the proposed method.

Originality/value

The novelty of the proposed work lies on the usage of anisotropic diffusion filter in the noisy concrete images. This research work gives the scope for structural damage evaluation by the automation techniques.

Details

International Journal of Structural Integrity, vol. 11 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 24 May 2023

Vijaya Prasad Burle, Tattukolla Kiran, N. Anand, Diana Andrushia and Khalifa Al-Jabri

The construction industries at present are focusing on designing sustainable concrete with less carbon footprint. Considering this aspect, a Fibre-Reinforced Geopolymer Concrete…

Abstract

Purpose

The construction industries at present are focusing on designing sustainable concrete with less carbon footprint. Considering this aspect, a Fibre-Reinforced Geopolymer Concrete (FGC) was developed with 8 and 10 molarities (M). At elevated temperatures, concrete experiences deterioration of its mechanical properties which is in some cases associated with spalling, leading to the building collapse.

Design/methodology/approach

In this study, six geopolymer-based mix proportions are prepared with crimped steel fibre (SF), polypropylene fibre (PF), basalt fibre (BF), a hybrid mixture consisting of (SF + PF), a hybrid mixture with (SF + BF), and a reference specimen (without fibres). After temperature exposure, ultrasonic pulse velocity, physical characteristics of damaged concrete, loss of compressive strength (CS), split tensile strength (TS), and flexural strength (FS) of concrete are assessed. A polynomial relationship is developed between residual strength properties of concrete, and it showed a good agreement.

Findings

The test results concluded that concrete with BF showed a lower loss in CS after 925 °C (i.e. 60 min of heating) temperature exposure. In the case of TS, and FS, the concrete with SF had lesser loss in strength. After 986 °C and 1029 °C exposure, concrete with the hybrid combination (SF + BF) showed lower strength deterioration in CS, TS, and FS as compared to concrete with PF and SF + PF. The rate of reduction in strength is similar to that of GC-BF in CS, GC-SF in TS and FS.

Originality/value

Performance evaluation under fire exposure is necessary for FGC. In this study, we provided the mechanical behaviour and physical properties of SF, PF, and BF-based geopolymer concrete exposed to high temperatures, which were evaluated according to ISO standards. In addition, micro-structural behaviour and linear polynomials are observed.

Details

Journal of Structural Fire Engineering, vol. 15 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 20 February 2020

Daniel Paul Thanaraj, Anand N. and Prince Arulraj

The purpose of this study is to investigate the effect of standard fire on the strength and microstructure properties of concrete with different strength grades.

Abstract

Purpose

The purpose of this study is to investigate the effect of standard fire on the strength and microstructure properties of concrete with different strength grades.

Design/methodology/approach

Different strength grades of concrete used for the investigation are M20, M30, M40 and M50. An electrical bogie hearth furnace was developed to simulate the International Standards Organization 834 standard fire curve.Concrete samples were subjected to high temperatures of 925, 1,029, 1,090 and 1,133°C for the duration of 1, 2, 3 and 4 h, respectively, as per standard fire curve. Compressive strength, tensile strength, thermal crack pattern and spalling of heated concrete specimens were evaluated by experimental investigation. Scanning electron microscopy and thermo-gravimetric analysis were performed to investigate the microstructure properties of heated concrete specimens.

Findings

Test results indicated reduction in the strength and changes in the microstructure properties of concrete exposed to elevated temperature. The degree of weight and the strength loss were found to be higher for concrete with higher grades. An empirical relation is proposed to determine the residual strength of concrete with different strength grade using regression analysis.

Social implications

Results of this research will be useful for the design engineers to understand the behavior of concrete exposed to elevated temperature as per standard fire.

Originality/value

When concrete is exposed to elevated temperature, its internal microstructure changes, thereby strength and durability of concrete deteriorates. The performance of concrete with different strength grade exposed to standard fire is well understood. This research’s findings will be useful for the designers to understand more about fire resistance of concrete. A simple relationship is proposed to determine the residual strength of concrete exposed to various durations of heating.

Details

Journal of Structural Fire Engineering, vol. 11 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 13 September 2021

Vijaya Prasad B., Arumairaj Paul Daniel, Anand N. and Siva Kumar Yadav

Concrete is a building material widely used for the infrastructural development. Cement is the binding material used for the development of concrete. It is the primary cause of CO2

174

Abstract

Purpose

Concrete is a building material widely used for the infrastructural development. Cement is the binding material used for the development of concrete. It is the primary cause of CO2 emission globally. The purpose of this study is to develop sustainable concrete material to satisfy the present need of construction sector. Geopolymer concrete (GPC) is a sustainable concrete developed without the use of cement. Therefore, investigations are being conducted to replace the cement by 100% with high calcium fly ash (FA) as binding material.

Design/methodology/approach

High calcium FA is used as cementitious binder, sodium hydroxide (NaOH) and sodium silicates (Na2SiO3) are used as alkaline liquids for developing the GPC. Mix proportions with different NaOH molarities of 4, 6, 8 and 10 M are considered to attain the appropriate mix. The method of curing adopted is ambient and oven curing. Workability, compressive strength and microstructure characteristics of GPC are analysed and presented.

Findings

An increase of NaOH in the mix decreases the workability. Compressive strength of 29 MPa is obtained for Mix-I with 8 M under ambient curing. A polynomial relationship is obtained to predict the compressive strength of GPC. Scanning electron microscope analysis is used to confirm the geo-polymerisation process in the microstructure of concrete.

Originality/value

This research work focuses on finding some alternative cementitious material for concrete that can replace ordinary portland cement (OPC) to overcome the CO2 emission owing to the utilisation of cement in the construction industry. An attempt has been made to use the waste material (high calcium FA) from thermal power plant for the production of GPC. GPC concrete is the novel building material and alternative to conventional concrete. It is the ecofriendly product contributing towards the improvement of the circular economy in the construction industry. There are several factors that affect the property of GPC such as type of binder material, molarity of activator solution and curing condition. The novelty of this work lies in the approach of using locally available high calcium FA along with manufactured sand for the development of GPC. As this approach is rarely investigated, to prove the attainment of compressive strength of GPC with high calcium FA, an attempt has been made during the present investigation. Other influencing parameter which affects the strength gain has also been analysed in this paper.

Details

Journal of Engineering, Design and Technology , vol. 20 no. 2
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 17 March 2022

Balamurali Kanagaraj, Tattukolla Kiran, Anand N., Khalifa Al Jabri and Justin S.

This study aims to develop geopolymer concrete (GPC) using manufactured sand (M-sand) and recycled concrete aggregate (RCA) under different curing conditions. GPC is a sustainable…

Abstract

Purpose

This study aims to develop geopolymer concrete (GPC) using manufactured sand (M-sand) and recycled concrete aggregate (RCA) under different curing conditions. GPC is a sustainable construction material developed with industrial waste products such as fly ash to eliminate the use of cement in the production of concrete. GPC requires heat curing for the attainment of early age strength. The development of GPC under heat curing conditions is a hard process in practice. To overcome such circumstances, an attempt was made to develop the GPC under different curing conditions with the aid of coarse aggregate (CA) and RCA. The influence of different curing conditions on strength gain and microstructural characteristics of GPC is investigated. Mechanical properties of GPC such as compressive strength, tensile strength, flexural strength and elastic modulus are reported and discussed.

Design/methodology/approach

This study focuses on the assessment of mechanical and microstructure characterization of eco-efficient GPC developed with natural CA and RCAs. The required optimum quantity of binder, alkali activator, alkaline liquid to binder ratio and aggregates was determined by appropriate trials. Three types of curing methods, namely, ambient, oven and water, were used for the development of GPC mixes. Following the properties of RCA, it is realistic to substitute up to 40% of coarser aggregates as the resulting aggregate mix falls within the requirements of the analyzed mix.

Findings

Special attention is required for the mix with RCA because the mix’s consistency is affected by the high water absorption of the RCA mix. GPC specimens cured at ambient and water conditions exhibited marginal variation in the compressive strength for both CA and RCA. The compressive strength of GPC mixes prepared with RCA was marginally higher than that of the GPC made with CA under different curing regimes. RCA can be used as a sustainable material in lieu of CA in GPC.

Originality/value

The main significance of this research work is to develop the optimal mix design with appropriate mix proportion. The present study proposes a satisfactory methodology that enhances the mechanical strength of GPC as the guidelines are not available in the standards to address this problem. Effective use of waste materials such as fly ash and recycled aggregate for the development of GPC is another major research focus in the proposed investigation.

Details

Construction Innovation , vol. 23 no. 3
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 15 May 2019

Daniel Paul Thanaraj, Anand N. and Prince Arulraj

This paper aims to explain the influence of Standard Fire as per ISO 834 on the strength and microstructure properties of concrete specimens with different strength grade.

Abstract

Purpose

This paper aims to explain the influence of Standard Fire as per ISO 834 on the strength and microstructure properties of concrete specimens with different strength grade.

Design/methodology/approach

The strength grades of concrete considered for the experimental investigation were Fck20, Fck30, Fck40 and Fck50. The specimens were heated up to 1, 2, 3 and 4 h as per standard fire curve. Effect of elevated temperature on compressive and flexural behavior of specimens with various strength grades was examined. Effects of age of concrete, weight loss, surface characteristics and thermal crack pattern were also investigated.

Findings

Experimental investigation shows that strength grade, duration of exposure and age of concrete are the key parameters affecting the residual strength of concrete. For the beams exposed to 3 and 4 h of heating, the residual flexural strength was found to be so insignificant that the specimens were not able to even sustain their own weight. The loss in compressive and flexural strength of Fck50 concrete specimens heated up to 1 h were found to be 26.41 and 86.03 per cent of the original unheated concrete, respectively. The weight loss was found to be more for higher grade concrete specimens, and it was about 8.38 per cent for Fck50 concrete. Regression analysis was carried out to establish the empirical relation between residual strength and grade of concrete. Scanning electron microscopy and thermogravimetric analysis were carried out to examine the damage level of fire-affected concrete specimens.

Originality/value

Empirical relationship was developed to determine the residual strength of concrete exposed to elevate temperature, and this will be useful for design applications. This database may be useful for identifying member strength of reinforced beams subjected to various durations of heating so that suitable repair technique can be adopted from the available database. It will be useful to identify the proper grade of concrete with regard to fire endurance, in the case of concrete under compression or flexure.

Details

Journal of Engineering, Design and Technology , vol. 17 no. 5
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 19 July 2022

G. Jaya Kumar, Tattukolla Kiran, N. Anand and Khalifa Al-Jabri

Most of the industrial buildings which are designed to moderate loads are constructed using light gauge cold-formed steel (CFS) sections. Residual mechanical properties of CFS…

Abstract

Purpose

Most of the industrial buildings which are designed to moderate loads are constructed using light gauge cold-formed steel (CFS) sections. Residual mechanical properties of CFS sections exposed to elevated temperature need to be investigated as it is necessary to predict the deterioration of elements to avoid failure of the structure or its elements. Also, it would be helpful to decide whether the structural elements need to be replaced or reused. The use of fire-resistant coatings in steel structures significantly reduces the cost of repairing structural elements and also the probability of collapse. This study investigates the effect of fire-resistant coating on post-fire residual mechanical properties of E350 steel grade.

Design/methodology/approach

In this study, an attempt has been made to evaluate the residual mechanical properties of E350 steel. A tensile coupon test was performed for the extracted specimens from the exposed CFS section to determine the mechanical properties. Four different fire-resistant coatings were selected and the sections were coated and heated as per ISO 834 fire temperature curve in the transient state for time durations of 30 minutes (821°C), 60 minutes (925°C), 90 minutes (986°C), and 120 minutes (1,029°C). After the exposure, all the coupon specimens were cooled by either ambient conditions (natural air) or water spraying before conducting the tension test on these specimens.

Findings

At 30 min exposure, the reduction in yield and ultimate strength of heated specimens was about 20 and 25% for air and water-cooled specimens compared with reference specimens. Specimens coated with vermiculite and perlite exhibited higher residual mechanical property up to 60 minutes than other coated specimens for both cooling conditions. Generally, water-cooled specimens had shown higher strength loss than air-cooled specimens. Specimens coated with vermiculite and perlite showed an excellent performance than other specimens coated with zinc and gypsum for all heating durations.

Originality/value

As CFS structures are widely used in construction practices, it is crucial to study the mechanical properties of CFS under post-fire conditions. This investigation provides detailed information about the physical and mechanical characteristics of E350 steel coated with different types of fire protection materials after exposure to elevated temperatures. An attempt has been made to improve the residual properties of CFS using the appropriate coatings. The outcome of the present study may enable the practicing engineers to select the appropriate coating for protecting and enhancing the service life of CFS structures under extreme fire conditions.

Details

Journal of Structural Fire Engineering, vol. 14 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 5 February 2021

Alwyn Varghese, Anand N., Diana Andrushia and Prince Arulraj

Aim of this research work is to examine the stress–strain behavior and modulus of elasticity of fiber-reinforced concrete (FRC) exposed to elevated temperature. The purpose of…

Abstract

Purpose

Aim of this research work is to examine the stress–strain behavior and modulus of elasticity of fiber-reinforced concrete (FRC) exposed to elevated temperature. The purpose of this paper is to study the effect of standard fire exposure on the mechanical and microstructure characteristics of concrete specimens with different strength grade.

Design/methodology/approach

An electrical bogie hearth furnace was developed to simulate the ISO 834 standard fire curve. Specimens were exposed to high temperatures of 821°C, 925°C and 986°C for the duration of 30, 60 and 90 min, respectively, as per standard fire curve. Peak stress, peak strain, modulus of elasticity and damage level of heated concrete specimens were evaluated by experimental investigation. SEM-based microstructure investigation has been carried out to analyze the microstructure characteristics of heated concrete specimens.

Findings

The results revealed that carbon fiber reinforced concrete was found to be better than the FRC made with other fibers on improving the modulus of elasticity of concrete. An empirical relationship has been established to predict the modulus of elasticity of temperature exposed specimens with different type of fiber and grade of concrete. In comparison with low melting point fibers, high melting point fibers exhibited higher modulus of elasticity under all tested conditions. Surface damage and porosity level of concrete with carbon and basalt fibers were found to be lower than other FRC.

Originality/value

Empirical relationship was developed to determine the modulus of elasticity of concrete exposed to elevate temperature, and this will be useful for concrete design applications. This research work may be useful for finding the residual compressive strength of concrete exposed to elevate temperature. So that it will be helpful to identify the suitable repair/retrofitting technique for reinforced concrete elements.

Details

World Journal of Engineering, vol. 18 no. 3
Type: Research Article
ISSN: 1708-5284

Keywords

1 – 10 of over 3000