1 – 10 of 337Shivendra Singh Rathore and Chakradhara Rao Meesala
The purpose of this paper is to investigate the effect of the replacement of natural coarse aggregate (NCA) with different percentages of recycled coarse aggregate (RCA) on…
Abstract
Purpose
The purpose of this paper is to investigate the effect of the replacement of natural coarse aggregate (NCA) with different percentages of recycled coarse aggregate (RCA) on properties of low calcium fly ash (FA)-based geopolymer concrete (GPC) cured at oven temperature. Further, this paper aims to study the effect of partial replacement of FA by ground granulated blast slag (GGBS) in GPC made with both NCA and RCA cured under ambient temperature curing.
Design/methodology/approach
M25 grade of ordinary Portland cement (OPC) concrete was designed according to IS: 10262-2019 with 100% NCA as control concrete. Since no standard guidelines are available in the literature for GPC, the same mix proportion was adopted for the GPC by replacing the OPC with 100% FA and W/C ratio by alkalinity/binder ratio. All FA-based GPC mixes were prepared with 12 M of sodium hydroxide (NaOH) and an alkalinity ratio, i.e. sodium hydroxide to sodium silicate (NaOH:Na2SiO3) of 1:1.5, subjected to 90°C temperature for 48 h of curing. The NCA were replaced with 50% and 100% RCA in both OPC and GPC mixes. Further, FA was partially replaced with 15% GGBS in GPC made with the above percentages of NCA and RCA, and they were given ambient temperature curing with the same molarity of NaOH and alkalinity ratio.
Findings
The workability, compressive strength, split tensile strength, flexural strength, water absorption, density, volume of voids and rebound hammer value of all the mixes were studied. Further, the relationship between compressive strength and other mechanical properties of GPC mixes were established and compared with the well-established relationships available for conventional concrete. From the experimental results, it is found that the compressive strength of GPC under ambient curing condition at 28 days with 100% NCA, 50% RCA and 100% RCA were, respectively, 14.8%, 12.85% and 17.76% higher than those of OPC concrete. Further, it is found that 85% FA and 15% GGBS-based GPC with RCA under ambient curing shown superior performance than OPC concrete and FA-based GPC cured under oven curing.
Research limitations/implications
The scope of the present paper is limited to replace the FA by 15% GGBS. Further, only 50% and 100% RCA are used in place of natural aggregate. However, in future study, the replacement of FA by different amounts of GGBS (20%, 25%, 30% and 35%) may be tried to decide the optimum utilisation of GGBS so that the applications of GPC can be widely used in cast in situ applications, i.e. under ambient curing condition. Further, in the present study, the natural aggregate is replaced with only 50% and 100% RCA in GPC. However, further investigations may be carried out by considering different percentages between 50 and 100 with the optimum compositions of FA and GGBS to enhance the use of RCA in GPC applications. The present study is further limited to only the mechanical properties and a few other properties of GPC. For wider use of GPC under ambient curing conditions, the structural performance of GPC needs to be understood. Therefore, the structural performance of GPC subjected to different loadings under ambient curing with RCA to be investigated in future study.
Originality/value
The replacement percentage of natural aggregate by RCA may be further enhanced to 50% in GPC under ambient curing condition without compromising on the mechanical properties of concrete. This may be a good alternative for OPC and natural aggregate to reduce pollution and leads sustainability in the construction.
Details
Keywords
To investigate the mechanical properties of geopolymer concrete at elevated temperatures.
Abstract
Purpose
To investigate the mechanical properties of geopolymer concrete at elevated temperatures.
Design/methodology/approach
The investigation involved studying the influence of partially replacing fly ash with ground granulated blast furnace slag (GGBS) at different proportions (5%, 10%, 15%, 20% and 25%) on the composition of the geopolymer. This approach aimed to examine how the addition of GGBS impacts the properties of the geopolymer material. The chemical NaOH was purchased from the local supplier of Jamshedpur. The alkali solution was prepared with a concentration of 12 M NaOH to produce the concrete. After several trials, the alkaline-to-binder ratio was determined to be 0.43.
Findings
The compressive strength values at 28 days for specimens FG1, FG2, FG3, FG4 and FG5 are 35.42 MPa, 41.26 MPa, 44.79 MPa, 50.51 MPa and 46.33 MPa, respectively. The flexural strength values at 28 days for specimens FG1, FG2, FG3, FG4 and FG5 are 5.31 MPa, 5.64 MPa, 6.12 MPa, 7.15 MPa and 6.48 MPa, respectively. The split tensile strength values at 28 days for specimens FG1, FG2, FG3, FG4 and FG5 are 2.82 MPa, 2.95 MPa, 3.14 MPa, 3.52 MPa and 3.31 MPa, respectively.
Originality/value
This approach allows for the examination of how the addition of GGBS affects the properties of the geopolymer material. Four different temperature levels were chosen for analysis: 100 °C, 300 °C, 500 °C and 700 °C. By subjecting the geopolymer samples to these elevated temperatures, the study aimed to observe any changes in their mechanical.
Details
Keywords
Shanmugan Subramani and Mutharasu Devarajan
Light emitting diode (LED) has been the best resource for commercial and industrial lighting applications. However, thermal management in high power LEDs is a major challenge in…
Abstract
Purpose
Light emitting diode (LED) has been the best resource for commercial and industrial lighting applications. However, thermal management in high power LEDs is a major challenge in which the thermal resistance (Rth) and rise in junction temperature (TJ) are critical parameters. The purpose of this work is to evaluate the Rth and Tj of the LED attached with the modified heat transfer area of the heatsink to improve thermal management.
Design/methodology/approach
This paper deals with the design of metal substrate for heatsink applications where the surface area of the heatsink is modified. Numerical simulation on heat distribution proved the influence of the design aspects and surface area of heatsink.
Findings
TJ was low for outward step design when compared to flat heatsink design (ΔT ∼ 38°C) because of increase in surface area from 1,550 mm2 (flat) to 3,076 mm2 (outward step). On comparison with inward step geometry, the TJ value was low for outward step configuration (ΔTJ ∼ 6.6°C), which is because of efficient heat transfer mechanism with outward step design. The observed results showed that outward step design performs well for LED testing by reducing both Rth and TJ for different driving currents.
Originality/value
This work is authors’ own design and also has the originality for the targeted application. To the best of the authors’ knowledge, the proposed design has not been tried before in the electronic or LED applications.
Details
Keywords
Mahesh Gaikwad, Suvir Singh, N. Gopalakrishnan, Pradeep Bhargava and Ajay Chourasia
This study investigates the impact of the fire decay phase on structural damage using the sectional analysis method. The primary objective of this work is to forecast the…
Abstract
Purpose
This study investigates the impact of the fire decay phase on structural damage using the sectional analysis method. The primary objective of this work is to forecast the non-dimensional capacity parameters for the axial and flexural load-carrying capacity of reinforced concrete (RC) sections for heating and the subsequent post-heating phase (decay phase) of the fire.
Design/methodology/approach
The sectional analysis method is used to determine the moment and axial capacities. The findings of sectional analysis and heat transfer for the heating stage are initially validated, and the analysis subsequently proceeds to determine the load capacity during the fire’s heating and decay phases by appropriately incorporating non-dimensional sectional and material parameters. The numerical analysis includes four fire curves with different cooling rates and steel percentages.
Findings
The study’s findings indicate that the rate at which the cooling process occurs after undergoing heating substantially impacts the axial and flexural capacity. The maximum degradation in axial and flexural capacity occurred in the range of 15–20% for cooling rates of 3 °C/min and 5 °C/min as compared to the capacity obtained at 120 min of heating for all steel percentages. As the fire cooling rate reduced to 1 °C/min, the highest deterioration in axial and flexural capacity reached 48–50% and 42–46%, respectively, in the post-heating stage.
Research limitations/implications
The established non-dimensional parameters for axial and flexural capacity are limited to the analysed section in the study owing to the thermal profile, however, this can be modified depending on the section geometry and fire scenario.
Practical implications
The study primarily focusses on the degradation of axial and flexural capacity at various time intervals during the entire fire exposure, including heating and cooling. The findings obtained showed that following the completion of the fire’s heating phase, the structural capacity continued to decrease over the subsequent post-heating period. It is recommended that structural members' fire resistance designs encompass both the heating and cooling phases of a fire. Since the capacity degradation varies with fire duration, the conventional method is inadequate to design the load capacity for appropriate fire safety. Therefore, it is essential to adopt a performance-based approach while designing structural elements' capacity for the desired fire resistance rating. The proposed technique of using non-dimensional parameters will effectively support predicting the load capacity for required fire resistance.
Originality/value
The fire-resistant requirements for reinforced concrete structures are generally established based on standard fire exposure conditions, which account for the fire growth phase. However, it is important to note that concrete structures can experience internal damage over time during the decay phase of fires, which can be quantitatively determined using the proposed non-dimensional parameter approach.
Details
Keywords
Francesco Romanò, Mario Stojanović and Hendrik C. Kuhlmann
This paper aims to derive a reduced-order model for the heat transfer across the interface between a millimetric thermocapillary liquid bridge from silicone oil and the…
Abstract
Purpose
This paper aims to derive a reduced-order model for the heat transfer across the interface between a millimetric thermocapillary liquid bridge from silicone oil and the surrounding ambient gas.
Design/methodology/approach
Numerical solutions for the two-fluid model are computed covering a wide parametric space, making a total of 2,800 numerical flow simulations. Based on the computed data, a reduced single-fluid model for the liquid phase is devised, in which the heat transfer between the liquid and the gas is modeled by Newton’s heat transfer law, albeit with a space-dependent Biot function Bi(z), instead of a constant Biot number Bi.
Findings
An explicit robust fit of Bi(z) is obtained covering the whole range of parameters considered. The single-fluid model together with the Biot function derived yields very accurate results at much lesser computational cost than the corresponding two-phase fully-coupled simulation required for the two-fluid model.
Practical implications
Using this novel Biot function approach instead of a constant Biot number, the critical Reynolds number can be predicted much more accurately within single-phase linear stability solvers.
Originality/value
The Biot function for thermocapillary liquid bridges is derived from the full multiphase problem by a robust multi-stage fit procedure. The derived Biot function reproduces very well the theoretical boundary layer scalings.
Details
Keywords
Qing Jiang, Yuhang Wan, Xiaoqian Li, Xueru Qu, Shengnan Ouyang, Yi Qin, Zhenyu Zhu, Yushu Wang, Hualing He and Zhicai Yu
This study aims to evaluate the thermal performance of sodium alginate (SA) aerogel attached to nano SiO2 and its radiative cooling effect on firefighting clothing without…
Abstract
Purpose
This study aims to evaluate the thermal performance of sodium alginate (SA) aerogel attached to nano SiO2 and its radiative cooling effect on firefighting clothing without environmental pollution.
Design/methodology/approach
SA/SiO2 aerogel with refractory heat insulation and enhanced radiative cooling performance was fabricated by freeze-drying method, which can be used in firefighting clothing. The microstructure, chemical composition, thermal stability, and thermal emissivity were analyzed using Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analyzer and infrared emissivity measurement instrument. The radiative cooling effect of aerogel was studied using thermal infrared imager and thermocouple.
Findings
When the addition of SiO2 is 25% of SA, the prepared aerogel has excellent heat insulation and a high radiative cooling effect. Under a clear sky, the temperature of SA/SiO2 aerogel is 9.4°C lower than that of pure SA aerogel and 22.1°C lower than that of the simulated environment. In addition, aerogel has more exceptional heat insulation effect than other common fabrics in the heat insulation performance test.
Research limitations/implications
SA/SiO2 aerogel has passive radiative cooling function, which can efficaciously economize global energy, and it is paramount to environment-friendly cooling.
Practical implications
This method could pave the way for high-performance cooling materials designed for firefighting clothing to keep maintain the wearing comfort of firefighters.
Originality/value
SA/SiO2 aerogel used in firefighting clothing can release heat to the low-temperature outer space in the form of thermal radiation to achieve its own cooling purpose, without additional energy supply.
Graphical abstract
Details
Keywords
Garima Nema and Karunamurthy K.
This study aims to provide an alternative adoption to overcome the energy crisis and environmental effluence by comparative theoretical and trial testing analysis of an innovative…
Abstract
Purpose
This study aims to provide an alternative adoption to overcome the energy crisis and environmental effluence by comparative theoretical and trial testing analysis of an innovative combined condenser unit over traditional individual condenser unit water heating systems.
Design/methodology/approach
The presented innovative new unit of the combined condenser heat pipe works efficiently through its improved idea and unique design, providing uniform heating to improve the heat transfer and, finally, the temperature of water increases without enhancing the cost. In this design, all these five evaporator units were connected with a single combined condenser unit in such a manner that after the condensation of heat transfer fluid vapour, it goes equally into the evaporator pipe.
Findings
The maximum temperature of hot water obtained from the combined condenser heating system was 60.6, 55.5 and 50.3°C at a water flow rate of 0.001, 0.002 and 0.003 kg/s, respectively. The first and second law thermodynamic efficiency of the combined condenser heating system were 55.4%, 60.5% and 89.0% and 2.6%, 3.7% and 4.1% at 0.001, 0.002 and 0.003 kg/s of water flow rates, respectively. The combined condenser heat pipe solar evacuated tube heating system promoting progressive performance is considered efficient and environment-friendly compared to the traditional condenser unit water heating system.
Originality/value
Innovative combined condenser heat pipe evacuated tube collector assembly was designed and developed for the study. A comparative theoretical and experimental energy-exergy performance analysis was performed of innovated collective condenser and traditional individual condenser heat pipe water heating system at various mass flow rate.
Details
Keywords
Upendra Bajpai, Palash Soni, Vivek Kumar Gaba and Shubhankar Bhowmick
When the temperature of an air conditioning unit’s fin surface goes below its dew point temperature, condensation forms on the unit’s surface. As a result, the cooling coil’s…
Abstract
Purpose
When the temperature of an air conditioning unit’s fin surface goes below its dew point temperature, condensation forms on the unit’s surface. As a result, the cooling coil’s performance is compromised. By altering the cross-section and heat conductivity of the fins, the performance of such systems can be improved. This study aims to analyze the thermal performance of longitudinal fins made up of a variable thickness (assuming constant weight) and functionally graded material.
Design/methodology/approach
Different grading parameters are considered for an exponential variation of thermal conductivity. The humidity ratio and the corresponding fin temperatures are assumed to follow a cubic relationship. The Bvp4c solver in MATLAB® is used to solve the differential heat transfer equation resulting from balancing heat transfer in a small segment.
Findings
Validation of the methodology is provided by previous research presented in this area. For different combinations of grading parameters, geometry parameters and relative humidity, the normalized temperature distribution along the fin length and fin efficiency contours are plotted, and the results are very promising.
Originality/value
When compared to the efficiency of an isotropic homogenous rectangular longitudinal fin with optimal geometry and grading parameters, a 17% increase in efficiency under fully wet conditions is measured. When it comes to fin design, these efficiency contour plots are extremely useful.
Details
Keywords
Mohammad A Gharaibeh and Ayman Alkhatatbeh
The continuous increase of energy demands is a critical worldwide matter. Jordan’s household sector accounts for 44% of overall electricity usage annually. This study aims to use…
Abstract
Purpose
The continuous increase of energy demands is a critical worldwide matter. Jordan’s household sector accounts for 44% of overall electricity usage annually. This study aims to use artificial neural networks (ANNs) to assess and forecast electricity usage and demands in Jordan’s residential sector.
Design/methodology/approach
Four parameters are evaluated throughout the analysis, namely, population (P), income level (IL), electricity unit price (E$) and fuel unit price (F$). Data on electricity usage and independent factors are gathered from government and literature sources from 1985 to 2020. Several networks are analyzed and optimized for the ANN in terms of root mean square error, mean absolute percentage error and coefficient of determination (R2).
Findings
The predictions of this model are validated and compared with literature-reported models. The results of this investigation showed that the electricity demand of the Jordanian household sector is mainly driven by the population and the fuel price. Finally, time series analysis approach is incorporated to forecast the electricity demands in Jordan’s residential sector for the next decade.
Originality/value
The paper provides useful recommendations and suggestions for the decision-makers in the country for dynamic planning for future resource policies in the household sector.
Details
Keywords
In the context of a developing country, Indian buildings need further research to channelize energy needs optimally to reduce energy wastage, thereby reducing carbon emissions…
Abstract
Purpose
In the context of a developing country, Indian buildings need further research to channelize energy needs optimally to reduce energy wastage, thereby reducing carbon emissions. Also, reduction in smart devices’ costs with sequential advancements in Information and Communication Technology have resulted in an environment where model predictive control (MPC) strategies can be easily implemented. This study aims to propose certain preemptive measures to minimize the energy costs, while ensuring the thermal comfort for occupants, resulting in better greener solutions for building structures.
Design/methodology/approach
A simulation-based multi-input multi-output MPC strategy has been proposed. A dual objective function involving optimized energy consumption with acceptable thermal comfort has been achieved through simultaneous control of indoor temperature, humidity and illumination using various control variables. A regression-based lighting model and seasonal auto-regressive moving average with exogenous inputs (SARMAX) based temperature and humidity models have been chosen as predictor models along with four different control levels incorporated.
Findings
The mathematical approach in this study maintains an optimum tradeoff between energy cost savings and satisfactory occupants’ comfort levels. The proposed control mechanism establishes the relationships of output variables with respect to control and disturbance variables. The SARMAX and regression-based predictor models are found to be the best fit models in terms of accuracy, stability and superior performance. By adopting the proposed methodology, significant energy savings can be accomplished during certain hours of the day.
Research limitations/implications
This study has been done on a specific corporate entity and future analysis can be done on other corporate or residential buildings and in other geographical settings within India. Inclusion of sensitivity analysis and non-linear predictor models is another area of future scope.
Originality/value
This study presents a dynamic MPC strategy, using five disturbance variables which further improves the overall performance and accuracy. In contrast to previous studies on MPC, SARMAX model has been used in this study, which is a novel contribution to the theoretical literature. Four levels of control zones: pre-cooling, strict, mild and loose zones have been used in the calculations to keep the Predictive Mean Vote index within acceptable threshold limits.
Details