Search results

1 – 10 of over 4000
Article
Publication date: 28 June 2022

Fairouz Al Gharib and Walid Marrouch

This study aims to examine the impact of local air pollution on the presence of central air conditioners in apartments in Lebanon.

Abstract

Purpose

This study aims to examine the impact of local air pollution on the presence of central air conditioners in apartments in Lebanon.

Design/methodology/approach

This study applies a Probit model in a unique data set on apartments’ listings for sale in Lebanon collected by Marrouch and Sayour (2021). The data set includes information about air pollution concentrations, dwellings’ characteristics, geographic features and location characteristics.

Findings

This study finds that local air pollution positively and significantly affects the presence of central air conditioning in dwellings. The estimated increase in the probability of having central air conditioning for a one microgram per cubic meter increase in Particulate Matter 2.5 concentration is 6.4%.

Research limitations/implications

The data set in this study is cross-sectional and thus does not capture variations over time for the examined variables.

Practical implications

The Probit regression approximates an equation that can predict the presence of central air conditioners in dwellings, which might be useful to policymakers.

Social implications

The findings suggest that local pollution is a significant factor in household behavior in Lebanon.

Originality/value

This paper adds to the scant literature studying the effects of air pollution on the presence of central air conditioning in developing countries. To the best of the authors’ knowledge, this is the first paper to study the impact of air pollution on the presence of central air conditioning in the Middle East and North Africa Region.

Details

International Journal of Housing Markets and Analysis, vol. 16 no. 5
Type: Research Article
ISSN: 1753-8270

Keywords

Book part
Publication date: 5 June 2023

Sonali A. Deshmukh, Praveen Barmavatu, Mihir Kumar Das, Bukke Kiran Naik, Vineet Singh Sikarwar, Alety Shivakrishna, Radhamanohar Aepuru and Rathod Subash

This study has covered many types of solar-powered air-conditioning systems that may be used as an alternative to traditional electrically powered air-conditioning systems in…

Abstract

This study has covered many types of solar-powered air-conditioning systems that may be used as an alternative to traditional electrically powered air-conditioning systems in order to reduce energy usage. Solar adsorption air cooling is a great alternative to traditional vapor compression air-conditioning. Solar adsorption has several advantages over traditional vapor-compression systems, including being a green cooling technology which uses solar energy to drive the cycle, using pure water as an eco-friendly HFC-free refrigerant, and being mechanically simple with only the magnetic valves as moving parts. Several advancements and breakthroughs have been developed in the area of solar adsorption air-conditioners during the previous decade. However, further study is required before this technology can be put into practise. As a result, this book chapter highlights current research that adds to the understanding of solar adsorption air-conditioning technologies, with a focus on practical research. These systems have the potential to become the next iteration of air-conditioning systems, with the benefit of lowering energy usage while using plentiful solar energy supplies to supply the cooling demand.

Article
Publication date: 15 February 2024

D.S.N. Senarathna, K.G.A.S. Waidyasekara and S.S.C.G. Vidana

The Heating, Ventilation and Air Conditioning (HVAC) system is a significant energy consumer in built environments, and the building energy consumption could be minimised by…

Abstract

Purpose

The Heating, Ventilation and Air Conditioning (HVAC) system is a significant energy consumer in built environments, and the building energy consumption could be minimised by optimising HVAC controls. Hence, this paper aims to investigate the applicability of Variable Refrigerant Flow (VRF) air conditioning systems for optimising the indoor comfort of buildings in Sri Lanka.

Design/methodology/approach

To address the research aim, the quantitative approach following the survey research strategy was deployed. Data collected through questionnaires were analysed using descriptive statistical tools, including Mean Rating (MR), Relative Important Index (RII) and Standard Deviation (SD).

Findings

The findings revealed that VRF systems are popularly used in Sri Lankan apartment buildings. Furthermore, energy efficiency and comfort were recognised as the most significant top-ranked benefits, while ventilation issues and initial cost were recognised as significant challenges. Moreover, the allocation of trained technicians and provision of proper ventilation through a Dedicated Outdoor Air System (DOAS) were highlighted as applicable mitigation strategies for the identified challenges in VRFs.

Practical implications

The study recommends VRF systems as a suitable technology to ensure energy efficiency, reduce GHG emissions and achieve climate performance within the built environment. The opportunities for adopting VRF systems for developing countries could be explored based on the research findings. The identified challenges would assist the design engineers and facilities professionals to devise suitable strategies to mitigate issues of VRF systems in developing countries.

Originality/value

This research provides empirical proof of the energy efficiency and comfort aspects of VRFs. The study has explored and recommended VRF technology as a beneficial application to overcome the persistent energy crisis in developing countries.

Details

Property Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0263-7472

Keywords

Article
Publication date: 22 August 2023

Xian Yun Tan, Norhayati Mahyuddin, Syahrul Nizam Kamaruzzaman, Norhayati Mat Wajid and Abdul Murad Zainal Abidin

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in…

Abstract

Purpose

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in the number of buildings is a positive sign of the rapid development of Malaysia. However, most Malaysian government office buildings tend to consume energy inefficiently due to lack of energy optimization. Most of the previous studies focused on the performance of green buildings in fulfilling the green development guidelines. As such, it is essential to study the energy performance of existing government office buildings that were constructed before most energy-efficient standards were implemented to mitigate energy wastage due to the lack of energy optimization. This study aims to analyse the energy performance of existing non-green Malaysian government office buildings and the factors that influence building energy consumption, as well as to evaluate the efficacy of the existing energy conservation measures.

Design/methodology/approach

This study was conducted by a literature review and case study. The chosen buildings are six government office building blocks located in Kuala Lumpur, the capital city of Malaysia. In this study, a literature review has been conducted on the common factors affecting energy consumption in office buildings. The energy consumption data of the buildings were collected to calculate the building energy intensity (BEI). The BEI was compared to the MS1525:2019 and GBI benchmarks to evaluate energy performance. SketchUp software was utilized to illustrate the solar radiation and sun path diagram of the case study buildings. Finally, recommendations were derived for retrofit strategies based on non-design factors and passive design factors.

Findings

In typical government office buildings, the air-conditioning system consumed the most energy at 65.5%, followed by lighting system at 22.6%, and the remaining 11.9% was contributed by office appliances. The energy performance of the case study buildings is considered as satisfactory as the BEI did not exceed the MS1525:2019 benchmark of 200 kWh/m2/year. The E Block recorded the highest BEI of 183.12 kWh/m2/year in 2020 due to its north-east orientation which is exposed to the most solar radiation. Besides, E Block consists of rooms that can accommodate large number of occupants. As such, non-design factors which include higher occupancy rate and higher cooling demand due to high outdoor temperature leads to higher energy consumption. By considering passive design features such as building orientation and building envelope thermal properties, energy consumption can be reduced significantly.

Originality/value

This study provided a comprehensive insight into the energy performance of Malaysian government office buildings, which were constructed before the energy-efficient standards being introduced. By calculating the BEI of six government office buildings, it is found that the energy performance of the case study buildings fulfils the MS1525 benchmark, and that all their BEIs are below 200 kWh/m2/year. Malaysia's hot and humid climate significantly affects a building's cooling load, and it is found the air-conditioning system is the major energy consumer of Malaysian government office buildings. This study discusses the efficacy of the energy-saving measures implemented in the case study buildings to optimize energy consumption. Recommendations were derived based on the non-design factors and passive design factors that affected the energy consumption of the case study building. It is envisioned that this study can provide practical strategies for retrofit interventions to reduce energy consumption in Malaysian office buildings as well as for office buildings that are in a similar climate.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Open Access
Article
Publication date: 28 February 2024

Hassan Th. Alassafi, Khalid S. Al-Gahtani, Abdulmohsen S. Almohsen and Abdullah M. Alsugair

Heating, ventilating, air-conditioning and cooling (HVAC) systems are crucial in daily health-care facility services. Design-related defects can lead to maintenance issues…

Abstract

Purpose

Heating, ventilating, air-conditioning and cooling (HVAC) systems are crucial in daily health-care facility services. Design-related defects can lead to maintenance issues, causing service disruptions and cost overruns. These defects can be avoided if a link between the early design stages and maintenance feedback is established. This study aims to use experts’ experience in HVAC maintenance in health-care facilities to list and evaluate the risk of each maintenance issue caused by a design defect, supported by the literature.

Design/methodology/approach

Following semistructured interviews with experts, 41 maintenance issues were identified as the most encountered issues. Subsequently, a survey was conducted in which 44 participants evaluated the probability and impact of each design-caused issue.

Findings

Chillers were identified as the HVAC components most prone to design defects and cost impact. However, air distribution ducts and air handling units are the most critical HVAC components for maintaining healthy conditions inside health-care facilities.

Research limitations/implications

The unavailability of comprehensive data on the cost impacts of all design-related defects from multiple health-care facilities limits the ability of HVAC designers to furnish case studies and quantitative approaches.

Originality/value

This study helps HVAC designers acquire prior knowledge of decisions that may have led to unnecessary and avoidable maintenance. These design-related maintenance issues may cause unfavorable health and cost consequences.

Article
Publication date: 27 April 2023

Gil Marom, Shahar Grossbard, Moti Bodek, Eran Neuman and David Elad

Ventilation of indoor spaces is required for the delivery of fresh air rich in oxygen and the removal of carbon dioxide, pollutants and other hazardous substances. The COVID-19…

Abstract

Purpose

Ventilation of indoor spaces is required for the delivery of fresh air rich in oxygen and the removal of carbon dioxide, pollutants and other hazardous substances. The COVID-19 pandemic brought the topic of ventilating crowded indoors to the front line of health concerns. This study developed a new biologically inspired concept of biomimetic active ventilation (BAV) for interior environments that mimics the mechanism of human lung ventilation, where internal air is continuously refreshed with the external environment. The purpose of this study is to provide a detailed proof-of-concept of the new BAV paradigm using computational models.

Design/methodology/approach

This study developed computational fluid dynamic models of unoccupied rooms with two window openings on one wall and two BAV modules that periodically translate perpendicular to or rotate about the window openings. This study also developed a time-evolving spatial ventilation efficiency metric for exploring the accumulated refreshment of the interior space. The authors conducted two-dimensional (2D) simulations of various BAV configurations to determine the trends in how the working parameters affect the ventilation and to generate initial estimates for the more comprehensive three-dimensional (3D) model.

Findings

Simulations of 2D and 3D models of BAV for modules of different shapes and working parameters demonstrated air movements in most of the room with good air exchange between the indoor and outdoor air. This new BAV concept seems to be very efficient and should be further developed.

Originality/value

The concept of ventilating interior spaces with periodically moving rigid modules with respect to the window openings is a new BAV paradigm that mimics human respiration. The computational results demonstrated that this new paradigm for interior ventilation is efficient while air velocities are within comfortable limits.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 33 no. 8
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 6 March 2023

Ishara Rathnayake, Pournima Sridarran, Mahesh Abeynayake and Shashini Jayakodi

The creation of occupant satisfaction can be reached through the involvement of building performance mandates (BPMs) while enhancing the functionality of buildings. BPMs comprise…

Abstract

Purpose

The creation of occupant satisfaction can be reached through the involvement of building performance mandates (BPMs) while enhancing the functionality of buildings. BPMs comprise five mandates namely, spatial performance, thermal performance, indoor air quality performance, acoustic performance, and visual performance. BPMs have been recognized as a vital element when refurbishing post-fire apparel buildings. However, the evaluation of post-fire refurbishment projects is mainly focused on mechanical and physical properties while ignoring the BPMs. Further, there is insufficient literature on the BPMs in post-fire building refurbishment. Hence, the purpose of this research is to identify the importance of BPMs, and its challenges and propose strategies to enhance the building performance of post-fire refurbished apparel manufacturing buildings in Sri Lanka.

Design/methodology/approach

The study was conducted by involving a qualitative research approach. An extensive literature review and eighteen semi-structured interviews under three fire-affected apparel cases were involved as data collection methods and collected data were analyzed using content analysis.

Findings

Findings highlighted the procedure of post-fire refurbishment and the importance of BPMs for apparel buildings to enhance building performance in post-fire situations. The research identified 42 challenges encountered in maintaining BPMs of post-fire refurbished apparel buildings and provided 70 strategies to overcome the identified challenges.

Originality/value

This study offers a comprehensive analysis of challenges in maintaining BPMs and strategies to overcome the identified challenges which facilitate enhancing the performance of post-fire refurbished apparel buildings in Sri Lanka.

Details

Built Environment Project and Asset Management, vol. 13 no. 3
Type: Research Article
ISSN: 2044-124X

Keywords

Article
Publication date: 18 December 2023

Hamdi Ercan, Cüneyt Öztürk and Mustafa Akın

This paper aims to assess the impact of electrifying the environmental control system (ECS) and ice protection system (IPS), the primary pneumatic system consumers in a…

Abstract

Purpose

This paper aims to assess the impact of electrifying the environmental control system (ECS) and ice protection system (IPS), the primary pneumatic system consumers in a conventional commercial transport aircraft, on aircraft weight, range, and fuel consumption.

Design/methodology/approach

The case study was carried out on Airbus A321-200 aircraft. Design, modelling and analysis processes were carried out on Pacelab SysArc software. Conventional and electrical ECS and IPS architectures were modelled and analysed considering different temperature profiles.

Findings

The simulation results have shown that the aircraft model with ±270 VDC ECS and IPS architecture is lighter, has a more extended range and has less relative fuel consumption. In addition, the simulation results showed that the maximum range and relative fuel economy of all three aircraft models increased slightly as the temperature increased.

Practical implications

Considering the findings in this paper, it is seen that the electrification of the conventional pneumatic system in aircraft has positive contributions in terms of weight, power consumption and fuel consumption.

Social implications

The positive contributions in terms of weight, power consumption and fuel consumption in aircraft will be direct environmental and economic contributions.

Originality/value

Apart from the conventional ECS and IPS of the aircraft, two electrical architectures, 230 VAC and ±270 VDC, were modelled and analysed. To see the effects of the three models created in different temperature profiles, analyses were done for cold day, ISA standard day and hot day temperature profiles.

Details

Aircraft Engineering and Aerospace Technology, vol. 96 no. 2
Type: Research Article
ISSN: 1748-8842

Keywords

Article
Publication date: 21 April 2022

Omar Al-Hafith, Satish BK and Pieter de Wilde

Traditional central courtyards have been advocated for being thermally efficient for hot-climate regions. However, exploring previous literature shows that it is not clear to what…

Abstract

Purpose

Traditional central courtyards have been advocated for being thermally efficient for hot-climate regions. However, exploring previous literature shows that it is not clear to what extent courtyards are truly thermally comfortable. This study determines the level of thermal comfort in residential courtyards in hot-climate regions, taking Baghdad as a case study.

Design/methodology/approach

This study develops a novel Courtyard Thermal Usability Index (CTUI) to quantify the ability of courtyards to provide thermal comfort to occupants. CTUI is the fraction of useable thermally comfortable hours in courtyards of the total occupation hours during a specific period. To operationalise CTUI, the research employs the Envi-met 4.2 simulation tool to determine the annual thermal conditions of 360 courtyards. An adaptive thermal comfort model developed by Al-Hafith in 2020 for Iraq is used to judge simulated thermal conditions and determine CTUI.

Findings

CTUI enables determining the level of thermal comfort courtyards offer to occupants by showing the ratio of the thermally comfortable period versus the occupation period. Results show that, in Iraq, annually, courtyards offer up to 38% comfortable hours out of the total potential occupation hours. The rest of the time the courtyard will not be comfortable, mostly due to overheating. When designing courtyards, the most effective geometric property impacting courtyards' thermal conditions is width/height. The most important microclimatic factor impacting occupants' thermal sensation is mean radiant temperature (MRT). This study can be used to inform designing thermally efficient courtyards for hot-climate regions.

Originality/value

This study presents the first assessment of the thermal efficiency of courtyards in hot-climate regions depending on an assessment of their ability to provide thermal comfort to occupants. The study presents a novel index that can be used to quantify the ability of courtyards to provide a thermally comfortable environment to occupants.

Details

Smart and Sustainable Built Environment, vol. 12 no. 3
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 31 October 2023

Eziaku Onyeizu Rasheed, Maryam Khoshbakht and George Baird

This paper aims to illustrate the extensive benefits of qualitative data analysis as a rarely undertaken process in post-occupancy evaluation surveys. As a result, there is…

Abstract

Purpose

This paper aims to illustrate the extensive benefits of qualitative data analysis as a rarely undertaken process in post-occupancy evaluation surveys. As a result, there is limited evidence of what occupants say about their buildings, especially for operational parameters, as opposed to how they rate them. While quantitative analyses provide useful information on how workers feel about workplace operational factors, qualitative analyses provide richer information on what aspects of the workplace workers identify as influential to their comfort, well-being and productivity.

Design/methodology/approach

The authors analysed 6,938 comments from office buildings worldwide on workers’ perception of workplace operational factors: design, storage, needs, space at desks and storage in their work environments. These factors were analysed based on the buildings’ design intent and use, and the associated comments were coded into positive, negative and balanced comments. The authors used a combination of coding, descriptive analysis, content analysis and word cloud to dissect the comments.

Findings

The findings showed that whereas workers rated these operational factors favourably, there were significantly more negative comments about each factor. Also, the Chi-square test showed a significant association (p < 0.01) between the satisfaction scale and the type of comments received for all the operational factors. This means that when a factor is rated high in the satisfaction score (5–7), there were fewer negative and more positive comments and vice versa. The word cloud analysis highlighted vital aspects of the office environment the workers mostly commented on, such as open plan design, natural lighting, space and windows, toilets, facilities, kitchens, meeting room booking systems, storage and furniture.

Research limitations/implications

This study highlights the importance of dissecting building occupants’ comments as integral to building performance monitoring and measurement. These emphasise the richness and value of respondents’ comments and the importance of critically analysing them. A limitation is that only 6,938 comments were viable for analysis because most comments were either incomplete with no meaning or were not provided. This underlines the importance of encouraging respondents to comment and express their feelings in questionnaire surveys. Also, the building use studies questionnaire data set presents extensive opportunities for further analyses of interrelationships between demographics, building characteristics and environmental and operational factors.

Practical implications

The findings from this study can be applied to future projects and facility management to maintain and improve office buildings throughout their life cycle. Also, these findings are essential in predicting the requirements of future workplaces for robust workplace designs and management.

Originality/value

The authors identified specific comments on the performance of workplaces across the globe, showing similarities and differences between sustainable, conventional, commercial and institutional buildings. Specifically, the analysis showed that office workers’ comments do not always corroborate the ratings they give their buildings. There was a significantly higher percentage of negative comments than positive comments despite the high satisfaction scores of the operational factors.

Details

Facilities , vol. 42 no. 3/4
Type: Research Article
ISSN: 0263-2772

Keywords

1 – 10 of over 4000