To read this content please select one of the options below:

APPLICATION OF 3‐D FINITE DIFFERENCE METHOD FOR INDUCTANCE CALCULATION OF AIR‐CORE COILS SYSTEM

K. Zakrzewski (Technical Univ. of Lodz Inst. of Electr. Machines and Transformers ul. Stefanowskiego 18/22 90‐924 Lodz, Poland)
M. Lukaniszyn (Technical Univ. of Opole Dept. of Electr. Engineering and Automatic Control ul. Luboszycka 7 45‐036 Opole, Poland)
69

Abstract

The paper deals with the inductance calculation of air‐core coils system by means of 3‐D analysis of magnetic field of the coils with rectangular cross‐section. The possibility of mutual and self‐inductance calculation is presented. For magnetic field calculation, the Finite Difference Method with application of fast calculating procedures was applied. The method of calculation has been verified by experiments. The obtained difference between calculating and measurement results is equal to a few percent. The computer program is usefull especially for asymmetrical configuration of the coils.

Citation

Zakrzewski, K. and Lukaniszyn, M. (1994), "APPLICATION OF 3‐D FINITE DIFFERENCE METHOD FOR INDUCTANCE CALCULATION OF AIR‐CORE COILS SYSTEM", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 13 No. 1, pp. 89-92. https://doi.org/10.1108/eb051847

Publisher

:

MCB UP Ltd

Copyright © 1994, MCB UP Limited

Related articles