To read this content please select one of the options below:

INFLUENCE OF GEOMETRICAL PARAMETERS UPON ELECTROSTATIC PRECIPITATOR EFFICIENCY

S. ABDEL‐SATTAR (Technical University Hamburg‐Marburg, Arbeitsbereich Theoretische Elektrotechnik, Harburger Schlosstrasse 20, 2100 Hamburg 90, West Germany Now, Electrical Engineering Department, Assiut University, Assiut, Egypt.)
125

Abstract

In this paper a modified numerical method for calculating the precipitation efficiency of wire‐duct electrostatic precipitators is reported. Variation of mobility for both ions and particles in space surrounding the energized wires is taken into consideration. This method is based on solving numerically the main set of equations, defining the ionized field with presence of dust particles. The precipitation efficiency of the electrostatic precipitators is determined for the cement industry. The effect of different geometrical parameters on the precipitation efficiency is also reported. The precipitation efficiency of the wire‐duct electrostatic precipitator as influenced by both the applied voltage and the gas flow speed is discussed in this paper. The present findings are correlated to the physics of electrical corona discharge.

Citation

ABDEL‐SATTAR, S. (1991), "INFLUENCE OF GEOMETRICAL PARAMETERS UPON ELECTROSTATIC PRECIPITATOR EFFICIENCY", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 10 No. 1, pp. 27-43. https://doi.org/10.1108/eb010328

Publisher

:

MCB UP Ltd

Copyright © 1991, MCB UP Limited

Related articles