To read this content please select one of the options below:

Parameters optimization design method for LLC resonant converter based on impedance model

Xuliang Yao (College of Intelligent Systems Science and Engineering, Harbin Engineering University, Harbin, China)
Xiao Han (College of Intelligent Systems Science and Engineering, Harbin Engineering University, Harbin, China)
Yuefeng Liao (School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou, China)
Jingfang Wang (College of Intelligent Systems Science and Engineering, Harbin Engineering University, Harbin, China)

Circuit World

ISSN: 0305-6120

Article publication date: 2 December 2022

Issue publication date: 9 January 2024

0

Abstract

Purpose

This paper aims to better design the resonant tank parameters for LLC resonant converter. And, it is found that under heavy load, the voltage gain is affected by junction capacitors of the primary side switching and the parasitic parameters of the secondary side diodes converted to the primary side, which will cause the voltage gain decreased when the switching frequency decreased.

Design/methodology/approach

This paper proposes an optimization parameters design method to solve this problem, which was based on impedance model considering the parasitic parameters of switching devices and diodes.

Findings

The effectiveness of the proposed method is verified by impedance Bode plots and experimental results.

Originality/value

From the perspective of impedance modeling, this paper finds the reasons for the insufficient voltage regulation capability of LLC resonant converters under heavy load and finds solutions through analysis.

Keywords

Citation

Yao, X., Han, X., Liao, Y. and Wang, J. (2024), "Parameters optimization design method for LLC resonant converter based on impedance model", Circuit World, Vol. 50 No. 1, pp. 82-89. https://doi.org/10.1108/CW-07-2022-0199

Publisher

:

Emerald Publishing Limited

Copyright © 2022, Emerald Publishing Limited

Related articles