OrbiLogic voltage detection system

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 1 June 2004

73

Keywords

Citation

(2004), "OrbiLogic voltage detection system", Anti-Corrosion Methods and Materials, Vol. 51 No. 3. https://doi.org/10.1108/acmm.2004.12851cad.001

Publisher

:

Emerald Group Publishing Limited

Copyright © 2004, Emerald Group Publishing Limited


OrbiLogic voltage detection system

OrbiLogic voltage detection system

Keywords: Voltage, Power supply, Machines

The ORBIMAT product range has been further improved with an OrbiLogic option available on the ORBIMAT 160C orbital welding power supplies which allows the machine to be run from either 110 or 230 V supplies with no changes required to the power supply (Plate 1).

Plate 1 ORBIMAT 160C

When swapping voltages the only change needed is the input plug. When the machine is connected to the mains supply the ORBIMAT 160C will detect which voltage is being used and make the necessary adjustments for that voltage.

The system not only makes the adjustments that the hardware requires but also adjusts the system software to suit the voltage being used. If an operator selects a program which is out of the range for the input voltage being used then a warning message will be displayed and it will not allow the procedure to be used.

With OrbiLogic in place the machine will never be damaged by connecting the machine to the wrong voltage and there are no switches or jumpers to be changed when changing power supply.

The ORBIMAT 160C also has a visual indicator to allow the operator to identify the supply voltage of the power supply in use.

Related articles