To read this content please select one of the options below:

Experimental behavior and reliability of predamaged concrete columns externally repaired with FRP spiral strips under axial compression

Chafika Ali Ahmed (Civil Engineering Department, Universite Mouloud Mammeri de Tizi Ouzou, Tizi Ouzou, Algeria)
Abdelmadjid Si Salem (Civil Engineering Department, Universite Mouloud Mammeri de Tizi Ouzou, Tizi Ouzou, Algeria and Laboratory of Construction Engineering and Architecture (LGCA), University of Bejaia, Bejaia, Algeria)
Souad Ait Taleb (Civil Engineering Department, Universite Mouloud Mammeri de Tizi Ouzou, Tizi Ouzou, Algeria)
Kamal Ait Tahar (Civil Engineering Department, University of Bouira, Bouira, Algeria)

World Journal of Engineering

ISSN: 1708-5284

Article publication date: 27 September 2022

Issue publication date: 12 January 2024

66

Abstract

Purpose

This paper aims to investigate the experimental behavior and the reliability of concrete columns repaired using fiber-reinforced polymers (FRPs) under axial compression loading. The expression of the ultimate axial resistance was assessed from the experimental data of damaged concrete cylinders repaired by externally bonded double-FRP spiral strips.

Design/methodology/approach

The tested columns bearing capacity mainly depends of the elasticity modulus of both damaged and undamaged concrete have been considered in addition to the applied load and the cylinder diameter as random variables in the expression of the failure criterion. The reliability indicators were assessed using first order second moment method.

Findings

The emphasized test results, statistically fitted show that the strength has been retrofitted for all repaired specimens whatever the degree of initial damage. However, the gain in axial strength is inversely proportional to the degree of damage.

Originality/value

The efficiency of a new FRP repair procedure using double-spiral strips was studied. This research provides a technical and economical solution for retrofitting existing concrete columns. Finally, the random character of the variables that govern the studied system shows the accuracy and safety of the proposed original design.

Keywords

Citation

Ali Ahmed, C., Si Salem, A., Ait Taleb, S. and Ait Tahar, K. (2024), "Experimental behavior and reliability of predamaged concrete columns externally repaired with FRP spiral strips under axial compression", World Journal of Engineering, Vol. 21 No. 1, pp. 115-126. https://doi.org/10.1108/WJE-06-2022-0248

Publisher

:

Emerald Publishing Limited

Copyright © 2022, Emerald Publishing Limited

Related articles