Influence of thermal and pH cycles on surface characteristics lithium disilicate glass-ceramic dental crowns milled with CAD/CAM process

Yajvinder Singh (Department of Mechanical Engineering, Guru Jambheshwar University of Science & Technology, Hisar, India)
Vishal Gulati (Department of Mechanical Engineering, Guru Jambheshwar University of Science & Technology, Hisar, India)

World Journal of Engineering

ISSN: 1708-5284

Article publication date: 17 June 2021

Issue publication date: 10 May 2022

95

Abstract

Purpose

The paper aims to evaluate the influence of thermo-chemical cycles of oral fluids on the surface attributes (roughness and microhardness) of lithium disilicate glass-ceramic (LDC) crown restorations manufactured with CAD/CAM technology.

Design/methodology/approach

There have been 24 LDC crowns manufactured using the CAD/CAM process for their respective preparation dies ply methyl methacrylate (PMMA) of mandibular left second premolar tooth (n = 8 each group). The standard procedure was used to glaze 16 crown samples (Groups 2 and 3).Samples of Group 3 were aged with thermal (563°C and 5563°C) and pH (2–14) cycles. All 24 samples were tested with a Profilometer and a Vicker hardness tester was used for their surface roughness and hardness measurement, respectively.

Findings

In statistical examination on SPSS Statistics 20 (IBM) software, of surface roughness values (Ra) and Vicker hardness values from different groups, Tukey HSD test was executed in one-way ANOVA (a = 0.05). The means Ra for groups were accordingly Group 3 > Group1 > Group 2 (p < 0.001). Similarly, micro-hardness was in order of Group 2 > Group 1 > Group 3 (p < 0.001).

Research limitations/implications

The research work does not have any limitations.

Originality/value

Surrounding temperature and pH significantly impact the surface characteristics of lithium disilicate crown restoration. The study also reveals the inverse relationship between surface roughness and surface hardness parameters. The observed results and facts revealed well in agreement with the past research studies.

Keywords

Acknowledgements

This study is supported in part by University Grant Commission (UGC), Government of India in the form of fellowship (Grant No. F1.1/2015, RGNF-2015–17-SC-HAR-17397).

The lead author duly acknowledged the financial support provided by University Grant commission (UGC), Govt. of India in the form of fellowship (Grant No. F1.1/2015, RGNF-2015-17-SC-HAR-17397).