To read this content please select one of the options below:

Effect of microwave operating power and reflow time on the microstructure and tensile properties of Sn–3.0Ag–0.5Cu/Cu solder joints

Mardiana Said (Advanced Soldering Materials Group, School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Pulau Pinang, Malaysia)
Muhammad Firdaus Mohd Nazeri (School of Materials Engineering, University Malaysia Perlis, Arau, Malaysia)
Nurulakmal Mohd Sharif (School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Pulau Pinang, Malaysia)
Ahmad Azmin Mohamad (Advanced Soldering Materials Group, School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Pulau Pinang, Malaysia)

Soldering & Surface Mount Technology

ISSN: 0954-0911

Article publication date: 28 July 2021

Issue publication date: 3 January 2022

187

Abstract

Purpose

This paper aims to investigate the morphology and tensile properties of SAC305 solder alloy under the influence of microwave hybrid heating (MHH) for soldering at different microwave parameters.

Design/methodology/approach

Si wafer was used as susceptor in MHH for solder reflow. Microwave operating power for medium and high ranging from 40 to 140 s reflow time was used to investigate their effect on the microstructure and strength of SAC305/Cu solder joints. The morphology and elemental composition of the intermetallic compound (IMC) joint were evaluated on the top surface and cross-sectional view.

Findings

IMC formation transformed from scallop-like to elongated scallop-like structure for medium operating power and scallop-like to planar-like structure for high operating power when exposed to longer reflow time. Compositional and phase analysis confirmed that the observed IMCs consist of Cu6Sn5, Cu3Sn and Ag3Sn. A thinner IMC layer was formed at medium operating power, 80 s (2.4 µm), and high operating power, 40 s (2.5 µm). The ultimate tensile strength at high operating power, 40 s (45.5 MPa), was 44.9% greater than that at medium operating power, 80 s (31.4 MPa).

Originality/value

Microwave parameters with the influence of Si wafer in MHH in soldering have been developed and optimized. A microwave temperature profile was established to select the appropriate parameter for solder reflow. For this MHH soldering method, the higher operating power and shorter reflow time are preferable.

Keywords

Acknowledgements

The first author would like to thank the Ministry of Higher Education and the University of Malaya for the SLPP scheme. The authors appreciate the financial support provided by Tin Industry (Research and Development) Board Research Grant 2021.

Credit Author statement Mardiana Said: Writing- original draft, methodology, investigation, visualization, project administration. Nurulakmal Mohd Sharif: Writing- review and editing. Muhammad Firdaus Mohd Nazeri: Writing- review and editing. Ahmad Azmin Mohamad: Supervision, conceptualization, writing- review and editing.

Citation

Said, M., Mohd Nazeri, M.F., Mohd Sharif, N. and Mohamad, A.A. (2022), "Effect of microwave operating power and reflow time on the microstructure and tensile properties of Sn–3.0Ag–0.5Cu/Cu solder joints", Soldering & Surface Mount Technology, Vol. 34 No. 1, pp. 31-44. https://doi.org/10.1108/SSMT-02-2021-0006

Publisher

:

Emerald Publishing Limited

Copyright © 2021, Emerald Publishing Limited

Related articles