To read this content please select one of the options below:

Development of planar electromagnetic sensor array for nitrate and sulphate detection in natural water sources

Alif Syarafi Mohamad Nor (Control and Mechatronic Engineering Department (CMED), Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia)
Mohd Amri Md Yunus (Infocomm Research Alliance (RA-Infocomm), Control and Mechatronic Engineering Deparment (CMED), Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia)
Sophan Wahyudi Nawawi (Material and Manufacturing Research Alliance (MMRA), Control and Mechatronic Engineering Department (CMED), Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia)
Sallehuddin Ibrahim (Infocomm Research Alliance (RA-Infocomm), Control and Mechatronic Engineering Deparment (CMED), Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia)
Mohd Fua'ad Rahmat (Infocomm Research Alliance (RA-Infocomm), Control and Mechatronic Engineering Department (CMED), Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia)

Sensor Review

ISSN: 0260-2288

Article publication date: 19 January 2015

327

Abstract

Purpose

The purpose of this study is to determine the contamination level in natural water resources because the tremendous development in the agriculture sector has increased the amount of contamination in natural water sources. Hence, the water is polluted and unsafe to drink.

Design/methodology/approach

Three types of sensor arrays were suggested: parallel, star and delta. The simulation of all types of sensor array was carried out to calculate the sensors’ impedance value, capacitance and inductance during their operation to determine the best sensor array. The contamination state was simulated by altering the electrical properties values of the environmental domain of the model to represent water contamination.

Findings

The simulation results show that all types of sensor array are sensitive to conductivity, σ, and permittivity, ɛ (i.e. contaminated water). Furthermore, a set of experiments was conducted to determine the relationship between the sensor’s impedance and the water’s nitrate and sulphate contamination. The performance of the system was observed where the sensors were tested, with the addition of distilled water with different concentrations of potassium nitrate and potassium sulphate. The sensitivity of the developed sensors was evaluated and the best sensor was selected.

Practical implications

Based on the outcomes of the experiments, the star sensor array has the highest sensitivity and can be used to measure nitrate and sulphate contaminations in water.

Originality/value

The star sensor array presented in this paper has the potential to be used as a useful low-cost tool for water source monitoring.

Keywords

Acknowledgements

The authors would like to acknowledge the Exploratory Research Scheme Grant (ERGS) from the Ministry of Higher Education Research (MOHE) Malaysia (Vote No. 4L039), the Sciencefund from the Ministry of Science, Technology and Innovation (MOSTI) Malaysia (Vote No. 4S098), and Universiti Teknologi Malaysia, Research University Grant Scheme (Vote No. 08J88).

Citation

Mohamad Nor, A.S., Md Yunus, M.A., Nawawi, S.W., Ibrahim, S. and Rahmat, M.F. (2015), "Development of planar electromagnetic sensor array for nitrate and sulphate detection in natural water sources", Sensor Review, Vol. 35 No. 1, pp. 106-115. https://doi.org/10.1108/SR-04-2014-633

Publisher

:

Emerald Group Publishing Limited

Copyright © 2015, Emerald Group Publishing Limited

Related articles