To read this content please select one of the options below:

Research on optimization sparse method for capacitive micromachined ultrasonic transducer array: heuristic algorithm

Tian Zhang (State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, China)
Wendong Zhang (Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China, Taiyuan, China)
XingLing Shao (State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, China)
Yang Wu (State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, China)

Sensor Review

ISSN: 0260-2288

Article publication date: 21 June 2021

Issue publication date: 10 August 2021

121

Abstract

Purpose

Because of the small size and high integration of capacitive micromachined ultrasonic transducer (CMUT) component, it can be made into large-scale array, but this lead to high hardware complexity, so the purpose of this paper is to use less elements to achieve better imaging results. In this research, an optimized sparse array is studied, which can suppress the side lobe and reduce the imaging artifacts compared with the equispaced sparse array with the same number of elements.

Design/methodology/approach

Genetic algorithm is used to sparse the CMUT linear array, and Kaiser window apodization is added to reduce imaging artifacts, the beam pattern and peak-to-side lobe ratio are calculated, point targets imaging comparisons are performed. Furthermore, a 256-elements CMUT linear array is used to carry out the imaging experiment of embedded mass and forearm blood vessel, and the imaging results are compared quantitatively.

Findings

Through the imaging comparison of embedded mass and forearm blood vessel, the feasibility of optimized sparse array of CMUT is verified, and the purpose of reducing the hardware complexity is achieved.

Originality/value

This research provides a basis for the large-scale CMUT array to reduce the hardware complexity and the amount of calculation. At present, the CMUT array has been used in medical ultrasound imaging and has huge market potential.

Keywords

Acknowledgements

This work is supported by National Natural Science Foundation of China as National Major Scientific Instruments Development Project (Grant No. 61927807), and Fund for Shan xi ‘1311 Project’ Key Subject Construction.

Citation

Zhang, T., Zhang, W., Shao, X. and Wu, Y. (2021), "Research on optimization sparse method for capacitive micromachined ultrasonic transducer array: heuristic algorithm", Sensor Review, Vol. 41 No. 3, pp. 260-270. https://doi.org/10.1108/SR-03-2021-0082

Publisher

:

Emerald Publishing Limited

Copyright © 2021, Emerald Publishing Limited

Related articles