To read this content please select one of the options below:

BGA substrate outgassing negative impact study on Cu wire bonding

Hanmin Zhang (School of Electronic Information Engineering, Tianjin University, Tianjin, China and NXP Semiconductor (China) Ltd., Tianjin, China)
Ming Hu (School of Electronic Information Engineering, Tianjin University, Tianjin, China)
Zhijie Wang (Department of Engineering, NXP Semiconductor (China) Ltd., Tianjin, China)
Qingchun He (Department of Engineering, NXP Semiconductor (China) Ltd., Tianjin, China)
Denghong Ye (Department of Engineering, NXP Semiconductor (China) Ltd., Tianjin, China)

Microelectronics International

ISSN: 1356-5362

Article publication date: 2 May 2017

105

Abstract

Purpose

The purpose of this paper is to attempt to study the failure mechanism of BGA (ball grid array) Cu wire bond ball lift and specifically focused on substrate outgassing’s impact on Cu wire bonding quality and reliability.

Design/methodology/approach

The Galvanic corrosion theory has been widely adopted in explaining the failure mechanism of Cu ball bond lift issue during reliability test or field application in the presence of moisture. In this study, ion chromatography was performed on BGA substrate halogen analysis. EDX (energy-dispersive X-ray spectroscopy) was also used to detect the contaminant’s element at the bottom surface of a window clamp. Further FTIR (Fourier transform infrared spectroscopy) analysis verified that the contamination is from substrate outgassing during wire bonding. A new window clamp design proved effective in reducing the negative impact from substrate outgassing during wire bonding.

Findings

The solder mask in a fresh substrate contains a chlorine element. The chlorine can be detected in the BGA substrate outgassing during wire bonding by FTIR and EDX analyses, which have a negative impact on the Cu wire bonding. The window clamp with a larger opening can reduce the negative impact of the Cu wire bonding from the BGA substrate outgassing.

Research limitations/implications

Because of the limitation of time and resources, bonding pad surface contamination from substrate outgassing and its correlation with Cu bonding ball lift failure after reliability test will be studied in depth later.

Originality/value

The BGA substrate outgassing has negative impacts on Cu wire bondability. A window clamp with a larger opening can reduce the negative impact from substrate outgassing.

Keywords

Citation

Zhang, H., Hu, M., Wang, Z., He, Q. and Ye, D. (2017), "BGA substrate outgassing negative impact study on Cu wire bonding", Microelectronics International, Vol. 34 No. 2, pp. 84-90. https://doi.org/10.1108/MI-03-2016-0030

Publisher

:

Emerald Publishing Limited

Copyright © 2017, Emerald Publishing Limited

Related articles