To read this content please select one of the options below:

Fire performance of hybrid mass timber beam-end connections with perpendicular-to-wood grain reinforcement

Oluwamuyiwa Okunrounmu (Department of Civil and Environmental Engineering, Carleton University, Ottawa, Canada)
Osama (Sam) Salem (Department of Civil Engineering, Faculty of Engineering, Lakehead University, Thunder Bay, Canada)
George Hadjisophocleous (Department of Civil and Environmental Engineering, Carleton University, Ottawa, Canada)

Journal of Structural Fire Engineering

ISSN: 2040-2317

Article publication date: 5 January 2022

Issue publication date: 22 September 2022

105

Abstract

Purpose

The fire resistance of timber structures is heavily dependent on the fire behaviour of the connections between its structural elements. The experimental study presented in this paper aimed to investigate the fire performance of glued-laminated timber beam connections reinforced perpendicular-to-wood grain with self-tapping screws (STS).

Design/methodology/approach

Two full-size fire experiments were conducted on glulam beam-end connections loaded in flexure bending. Two connection configurations, each utilizing four steel bolts arranged in two different patterns, were reinforced perpendicular to wood grain using STS. The bolt heads and nuts and the steel plate top and bottom edges were fire protected using wood plugs and strips, respectively. Each connection configuration was loaded to 100% of the ultimate design load of the weakest unreinforced configuration. The test assemblies were exposed to elevated temperatures that followed the CAN/ULC-S101 standard fire time–temperature curve.

Findings

The experimental results show that the influence of the STS was significant as it prevented the occurrence of wood splitting and row shear-out and as a result, increased the fire resistance time of the connections. The time to failure of both connection configurations exceeded the minimum fire resistance rating specified as 45 min for combustible construction in applicable building codes.

Originality/value

The experimental data show the effectiveness of a simple fire protection system (i.e. wood plugs and strips) along with the utilization of STS on the rotational behaviour, charring rate, fire resistance time and failure mode of the proposed hybrid mass timber beam-end connection configurations.

Keywords

Acknowledgements

The research study presented in this paper has been supported in part by the NSERC Discovery grants awarded to the second and third authors. The authors of this paper would like to thank lab technologist Cory Hubbard for his great assistance in the Civil Engineering’s Structures Laboratory at Lakehead University.

Citation

Okunrounmu, O., Salem, O.(S). and Hadjisophocleous, G. (2022), "Fire performance of hybrid mass timber beam-end connections with perpendicular-to-wood grain reinforcement", Journal of Structural Fire Engineering, Vol. 13 No. 4, pp. 433-450. https://doi.org/10.1108/JSFE-06-2021-0036

Publisher

:

Emerald Publishing Limited

Copyright © 2021, Emerald Publishing Limited