Abstract

Purpose

Nowadays, with the expansion of terrorist operations around the world and also the dangers of accidental explosions, the need to design structures resistant to this phenomenon for the protection and safety of its citizens is inevitable. Tall buildings are one of the most important issues because of which those behavior should be investigated against the blast loading.

Design/methodology/approach

In this paper, the authors used a simple method for investigating the dynamic response of tall buildings with the combined system of framed tube, shear core and outrigger-belt truss located at different heights of the building’s that were subjected to blast loading. This proposed model is based on the development of a continuum model and the ruling equations that have been obtained using the energy principle predict the whole structure idealized as a shear and flexural cantilever beam with rotational springs at the belt truss location.

Findings

The mathematical procedure shows a good understanding of the structural behavior and is suitable for a quick evaluation during the preliminary design stage, which requires less time. Moreover, it was concluded that the present blast load idealization can be used to reasonably assess the response of tall buildings subjected to blast load.

Originality/value

The comparative analysis in this paper could give other engineers a simple analysis method for the preliminary analysis and design of tall building analysis. Numerical example is given to illustrate the ease of application and the accuracy of the suggested model.