To read this content please select one of the options below:

Dynamic behaviour of a three fluid heat exchanger subjected to step change in inlet temperature of hot and cold fluids

Veerabhadrappa Kavadiki (Department of Mechanical Engineering, BMS College of Engineering, Bangalore, India)
Vinayakaraddy (Department of Mechanical Engineering, PES Institute of Technology, India)
Meghana H Chaturvedi (Department of Mechanical Engineering, PES Institute of Technology, Bangalore, India)
Krishna Venkataram (Department of Mechanical Engineering, PES Institute of Technology, Bangalore, India)
K N Seetharamu (Department of Mechanical Engineering, PES Institute of Technology, Bangalore, India)

International Journal of Numerical Methods for Heat & Fluid Flow

ISSN: 0961-5539

Article publication date: 3 August 2015

192

Abstract

Purpose

The purpose of this paper is to analyse the dynamic behaviour of a three-fluid heat exchanger subjected to a step change in the temperature and velocity of the fluids at the inlet.

Design/methodology/approach

The analysis is carried out using the finite element methodology, adopting the Galerkin’s approach, using implicit method for transient behaviour.

Findings

The effect of step changes in the inlet temperature of hot and cold fluids show that an increase in the fluid inlet temperatures leads to increased outlet temperatures of all fluids and decreased hot fluid effectiveness. The exit temperatures of the fluids do not show any response initially for a certain period of time with the step changes. The time to reach steady state is independent of the step change in inlet temperature of the hot and the cold fluids.

Research limitations/implications

The findings of this paper is limited to constant property situations.

Practical implications

The findings will be useful in designing control and regulation systems of heat exchangers used in different industrial processes and operations, such as in nuclear reactors, cryogenic and petrochemical process plants.

Social implications

The analysis provides a time frame in which the controls and regulation systems work, so that the necessary safety precautions for the people working in the surrounding area can be taken care of.

Originality/value

As per the best knowledge of the authors, none of the papers so far have discussed the effect of the change in the inlet temperature and velocity of both the fluids. Performance parameters such as effectiveness, time to reach steady state, etc. have not been studied so far.

Keywords

Citation

Kavadiki, V., Vinayakaraddy,  ., Chaturvedi, M.H., Venkataram, K. and Seetharamu, K.N. (2015), "Dynamic behaviour of a three fluid heat exchanger subjected to step change in inlet temperature of hot and cold fluids", International Journal of Numerical Methods for Heat & Fluid Flow, Vol. 25 No. 6, pp. 1311-1321. https://doi.org/10.1108/HFF-07-2014-0227

Publisher

:

Emerald Group Publishing Limited

Copyright © 2015, Emerald Group Publishing Limited

Related articles