TY - JOUR AB - Purpose The purpose of this paper is to recommend a validated numerical model for simulation the flue gases heat recovery recuperators. Due to fulfill of this demand, the influences of ash fouling characteristics during the transient/steady-state simulation and optimization of a 3D complex heat exchanger equipped with inner plain fins and side plate fins are studied.Design/methodology/approach For the particle dispersion modeling, the discrete phase model is applied and the flow field has been solved using SIMPLE algorithm.Findings According to obtained results, for the recuperator equipped with combine inner plain and side plate fins, determination of ash fouling characteristics is really important, effective and determinative. It is clear that by underestimating the ash fouling characteristics, the achieved results are wrong and different with reality.Originality/value Finally, the configuration with inner plain fins with characteristics of: di =5 mm, do = 6 mm, dg = 2 mm, dk = 3 mm and NIPFT = 9 and side plate fins with characteristics of: TF = 3 mm, PF = 19 mm, NSPF = 17·2 = 34, WF = 10 mm, HF = 25 mm, LF = 24 mm and ß = 0° is introduced as the optimum model with the best performance among all studied configurations. VL - 30 IS - 5 SN - 0961-5539 DO - 10.1108/HFF-01-2019-0036 UR - https://doi.org/10.1108/HFF-01-2019-0036 AU - Abbasian Arani Ali Akbar AU - Arefmanesh Ali AU - Ehteram Hamidreza PY - 2019 Y1 - 2019/01/01 TI - Numerical optimization of obstructed high temperature heat exchanger for recovery from the flue gases by considering ash fouling characteristics T2 - International Journal of Numerical Methods for Heat & Fluid Flow PB - Emerald Publishing Limited SP - 2273 EP - 2303 Y2 - 2024/04/26 ER -