To read this content please select one of the options below:

Study on the interference between cathodic protection systems of gas station and long distance trunk pipeline

Gan Cui (College of Pipeline and Civil Engineering, China University of Petroleum (East China), Qingdao, China and Shandong Provincial Key Laboratory of Oil & Gas Storage and Transportation Safety, Qingdao, China and Qingdao Key Laboratory of Circle Sea of Oil & Gas Storage and Transportation Technology, Qingdao, China)
Zili Li (College of Pipeline and Civil Engineering, China University of Petroleum (East China), Qingdao, China and Shandong Provincial Key Laboratory of Oil & Gas Storage and Transportation Safety, Qingdao, China and Qingdao Key Laboratory of Circle Sea of Oil & Gas Storage and Transportation Technology, Qingdao, China)
Chao Yang (College of Pipeline and Civil Engineering, China University of Petroleum (East China), Qingdao, China and Shandong Provincial Key Laboratory of Oil & Gas Storage and Transportation Safety, Qingdao, China and Qingdao Key Laboratory of Circle Sea of Oil & Gas Storage and Transportation Technology, Qingdao, China)
Xiaoyong Ding (Oil and Gas Control Centre, Beijing, China)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 1 January 2016

287

Abstract

Purpose

Under normal conditions, there are different protection objects inside and outside the gas station, so two sets of independent cathodic protection systems are adopted. At the same time, an insulating flange is applied at the position where trunk pipelines access to the gas station, which realizes electrical isolation of the structures inside and outside the station. However, as a result of short distance between the two cathodic protection systems, there will be stray current interference between them. The purpose of this paper was to study on the interference between cathodic protection systems of gas station and long distance trunk pipeline.

Design/methodology/approach

Based on the above, in this paper, first, the mathematical model of interference between cathodic protection systems was established and the control equations solved using the boundary element method. Second, the influence of cathodic protection system of gas station on long distance trunk pipeline and the influence of cathodic protection system of long distance trunk pipeline on gas station were studied separately using BEASY software. Finally, a new thought of cathodic protection design for local station was put forward.

Findings

It was concluded that there were serious interference problems between the cathodic protection systems of gas station and long distance trunk pipeline. By moving the potential control point to area outside the influence scope of anode ground bed could avoid the influence of cathodic protection system of gas station on long distance trunk pipeline. By moving the auxiliary anodes away from gas station could avoid the influence of cathodic protection system of long distance trunk pipeline on pipelines in gas station. The new thought of cathodic protection design could avoid the interference between the cathodic protection systems effectively.

Originality/value

It is considered that the results can guide cathodic design for gas station and long distance trunk pipeline. The results can also avoid the interference corrosion between the structures in gas station and trunk pipeline.

Keywords

Acknowledgements

This work was financially supported by the Natural Science Foundation of China (No. 50804053) and the National Science and Technology Major Projects of Large Oil and Gas Fields and Coal Bed Methane Development (2008ZX05017-04-01).

Citation

Cui, G., Li, Z., Yang, C. and Ding, X. (2016), "Study on the interference between cathodic protection systems of gas station and long distance trunk pipeline", Anti-Corrosion Methods and Materials, Vol. 63 No. 5, pp. 405-413. https://doi.org/10.1108/ACMM-11-2014-1466

Publisher

:

Emerald Group Publishing Limited

Copyright © 2016, Emerald Group Publishing Limited

Related articles