To read this content please select one of the options below:

Long exposure test in air, conducted on super-lattice coatings at 850°C for 4,000 hours

Tomasz Pawel Dudziak (Centre for High Temperature Studies, Foundry Research Institute, Krakow, Poland.)
Hailiang Du (Alstom Power, Rugby, United Kingdom.)
Prasanta Datta (Advanced Materials Research Institute, Northumbria University, Newcastle upon Tyne, United Kingdom.)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 2 November 2015

93

Abstract

Purpose

The purpose of this study is to investigate the high-temperature behavior of newly developed high-impulse power magnetron sputtering system (HIPIMS) coatings and compare them to the standard TiAlCr system deposited on to a Ti–Al intermetallic alloy. The corrosion test was performed in air for 4,000 hours at 850°C.

Design/methodology/approach

In this study, air oxidation test was performed at high temperature. Design and methodology is described in detail in the methodology section in the submitted manuscript. The test was carried out by discontinuous exposure of the three different systems produced by different deposition technique. The exposed samples were investigated using scanning electron microscope coupled with energy dispersive X-ray spectroscopy. The exposed samples were investigated from the surface and cross-sections.

Findings

The performed study shows that HIPIMS coatings had a much better oxidation resistance at a high temperature than that offered by the standard physical vapor deposition (PVD) system. HIPIMS costing developed Al–Cr oxide on the surface; however, cracks and detachments were found at the interface between the coating and the substrate. TiAlCr coating spalled off from the material due to the critical thickness reached; moreover, high brittleness and lack of adherence were found. Due to poor oxidation resistance, TiAlCr coating was discarded from the test after 3,000 hours of exposure.

Originality/value

The work performed in this study was designed for 4,000 hours oxidation at 850°C. The long-term exposures are not commonly met in the research work due to the cost and time. The work clearly shows differences between new type of coatings and standard PVD system applied on TiAl lightweight alloy.

Keywords

Acknowledgements

The authors gratefully acknowledge the financial support from The European Union (INNOVATIAL-Project NMP3-CT-2005-515844).

Citation

Dudziak, T.P., Du, H. and Datta, P. (2015), "Long exposure test in air, conducted on super-lattice coatings at 850°C for 4,000 hours", Anti-Corrosion Methods and Materials, Vol. 62 No. 6, pp. 394-399. https://doi.org/10.1108/ACMM-03-2014-1366

Publisher

:

Emerald Group Publishing Limited

Copyright © 2015, Emerald Group Publishing Limited

Related articles