Books and journals Case studies Expert Briefings Open Access
Advanced search

Improvement of surface properties of AISI 316L SS by oxygen and helium ion implantation

V. Muthukumaran (Mechanical Engineering, Kumaraguru College of Technology, Coimbatore, India)
M. Senthil kumar (Mechanical Engineering, PSG College of Technology, Coimbatore, India)
V. Selladurai (Mechanical Engineering, Coimbatore Institute of Technology, Coimbatore, India)

Journal of Engineering, Design and Technology

ISSN: 1726-0531

Publication date: 22 March 2013

Abstract

Purpose

–

The purpose of the paper is to study effect of the implantation of oxygen and helium ions on the corrosion performance of the AISI3l6L stainless steel. It presents useful new results which allows one to draw conclusions as to the suitability of the helium and oxygen ion implanted AISI 316L stainless steel for biomedical use in the body.

Design/methodology/approach

–

The implantation of oxygen and helium ions was done on AISI 316L SS at an energy level of 100 keV at a dose of 1×1017 ions/cm2, at room temperature. In order to simulate the natural tissue environment, an electrochemical test using cyclic polarization was done in a 0.9 percent sodium chloride solution at a pH value of 6.3 at 37°C. This was carried out on both the virgin and implanted AISI 316L stainless steel for the purpose of comparing performance. In addition to this, the hardness of the virgin and implanted samples was also studied using Vickers microhardness tester with varying loads. Besides, the surface morphologies of the implanted samples and the corroded samples were studied with XRD and SEM.

Findings

–

From the study the following findings are made. First, the XRD and SEM results were found to be in accordance with the corrosion test results. Second, the general corrosion behavior showed a significant improvement in the case of both helium implanted (icorr=0.0689 mA/cm2) and oxygen implanted (icorr=1.104 mA/cm2), when compared to the virgin AISI 316L SS (icorr=1.2187 mA/cm2). The pitting corrosion showed a significant improvement for helium implanted (Epit=230 mV) when compared to virgin material (Epit=92 mV). The oxygen implanted has not shown any improvement (Epit=92 mV). The surface hardness is found to be 1202 HV for helium implanted and 1020 HV for oxygen implanted, while it is found to be 195 HV for the virgin material. The hardness of the helium and oxygen implanted samples is found to be increased by about 600 percent and 500 percent, respectively, when compared to the virgin samples. Helium implanted samples show better performance in terms of corrosion resistance and hardness when compared to those of the oxygen implanted samples.

Originality/value

–

Although a number of authors have conducted many research on AISI 316L stainless steel, this work has original experimental results in terms of the oxygen and helium ion implantation parameters used and the specific tests: microhardness, electrochemical corrosion test, SEM and XRD that were used. It thus presents useful new results which allows one to draw conclusions as to the suitability of the Helium and Oxygen ion implanted AISI 316L stainless steel for biomedical use.

Keywords

  • Ion implantation
  • AISI 316L stainless steel
  • Corrosion
  • Hardness
  • SEM
  • Stainless steel

Citation

Muthukumaran, V., Senthil kumar, M. and Selladurai, V. (2013), "Improvement of surface properties of AISI 316L SS by oxygen and helium ion implantation", Journal of Engineering, Design and Technology, Vol. 11 No. 1, pp. 34-43. https://doi.org/10.1108/17260531311309116

Download as .RIS

Publisher

:

Emerald Group Publishing Limited

Copyright © 2013, Emerald Group Publishing Limited

Please note you do not have access to teaching notes

You may be able to access teaching notes by logging in via Shibboleth, Open Athens or with your Emerald account.
Login
If you think you should have access to this content, click the button to contact our support team.
Contact us

To read the full version of this content please select one of the options below

You may be able to access this content by logging in via Shibboleth, Open Athens or with your Emerald account.
Login
To rent this content from Deepdyve, please click the button.
Rent from Deepdyve
If you think you should have access to this content, click the button to contact our support team.
Contact us
Emerald Publishing
  • Opens in new window
  • Opens in new window
  • Opens in new window
  • Opens in new window
© 2021 Emerald Publishing Limited

Services

  • Authors Opens in new window
  • Editors Opens in new window
  • Librarians Opens in new window
  • Researchers Opens in new window
  • Reviewers Opens in new window

About

  • About Emerald Opens in new window
  • Working for Emerald Opens in new window
  • Contact us Opens in new window
  • Publication sitemap

Policies and information

  • Privacy notice
  • Site policies
  • Modern Slavery Act Opens in new window
  • Chair of Trustees governance statement Opens in new window
  • COVID-19 policy Opens in new window
Manage cookies

We’re listening — tell us what you think

  • Something didn’t work…

    Report bugs here

  • All feedback is valuable

    Please share your general feedback

  • Member of Emerald Engage?

    You can join in the discussion by joining the community or logging in here.
    You can also find out more about Emerald Engage.

Join us on our journey

  • Platform update page

    Visit emeraldpublishing.com/platformupdate to discover the latest news and updates

  • Questions & More Information

    Answers to the most commonly asked questions here