TY - JOUR AB - Inverter‐fed asynchronous motors represent today a source of disturbance in electric drives, because they irradiate outside their frames electromagnetic waves with different frequencies. Knowledge of the disturbances generated inside the drive is necessary. In the paper the influence of the sampling time on the distortion between predicted and actual armature current is evaluated on the basis of an analytical calculus procedure, that allows for an easy evaluation of the harmonic contents of the currents. This is the first step towards the evaluation of the causes of environmental electromagnetic disturbances. VL - 17 IS - 2 SN - 0332-1649 DO - 10.1108/03321649810369393 UR - https://doi.org/10.1108/03321649810369393 AU - Guidobaldi R. AU - Pagano E. AU - Veneri O. PY - 1998 Y1 - 1998/01/01 TI - Influence of the sampling period on sinusoidal steady‐state operations of inverter‐fed asynchronous motors T2 - COMPEL - The international journal for computation and mathematics in electrical and electronic engineering PB - MCB UP Ltd SP - 219 EP - 224 Y2 - 2024/04/25 ER -