TY - JOUR AB - Purpose– There have been several recent cases reported in Malaysian newspapers of complaints about the impact of construction works on the physical conditions of the surrounding buildings. The purpose of this paper is to present the findings of a study conducted on a complaint received by the Local Authority in Selangor, Malaysia, about the impact of adjacent new construction works on the conditions of existing buildings in the neighbouring vicinity.Design/methodology/approach– The sample case study consists of 28 units of two‐storey terrace houses, and the instrument used was the inspection form for building inspections. A building survey was carried out for all the buildings in the case study. Two teams conducted the survey. Each team was led by a professional building surveyor and assisted by two assistant building surveyors. Apart from basic surveying tools, a digital calliper was also used to measure cracks. Crack‐width data were collected and analysed using the statistical package for social sciences (SPSS) software.Findings– The findings show that the adjacent new construction works have impacted the existing buildings nearby. A numbers of cracks of various magnitudes were identified in all the existing houses. One significant finding is that there appears to be no significant relationship between the cracks on the interior and the exterior, nor between the original and the renovated parts, of the existing buildings.Originality/value– The significant number of cracks identified in the existing houses implies that the cracks were associated with the impacts from the new construction works. However, the primary cause of the building cracks was difficult to determine. It is therefore proposed that the Local Authority should establish guidelines at the local level for new construction works to prepare an inspection report on the condition of existing buildings in the surrounding area before the project commences. Building condition reports can then be used for reference in the event of claims received from the surrounding building owners alleging that the new construction works have adversely impacted the existing conditions of nearby buildings. VL - 29 IS - 4 SN - 0263-080X DO - 10.1108/02630801111162396 UR - https://doi.org/10.1108/02630801111162396 AU - Irfan Che‐Ani Adi AU - Mohd Noor Zaleha AU - Sui Pheng Low AU - Mohd Tawil Norngainy AU - Mohd Tahir Mazlan PY - 2011 Y1 - 2011/01/01 TI - Building cracks: evidence on the impact of new construction works on existing buildings T2 - Structural Survey PB - Emerald Group Publishing Limited SP - 337 EP - 351 Y2 - 2024/04/23 ER -