TY - JOUR AB - Purpose– The present study aims to find out the best polymer/polymer pair in electrical insulating applications. Moreover, the effects of different polymer counterpart and applied load on the friction and wear behaviour of PA 46 + 30%GFR and unfilled PA 66 thermoplastic polymers are to be studied.Design/methodology/approach– Friction and wear tests vs PA 46 + 30%GFR and PPS + 30%GFR polymer composites were carried out on a pin‐on‐disc arrangement and at a dry sliding conditions. Tribological tests were performed at room temperature under 20, 40 and 60 N loads and at 0.5 m/s sliding speed.Findings– The results showed that, the coefficient of friction decreases with the increasing of load (up to 40 N) for PA 46 + 30%GFR composite and polyamide (PA) 66 polymer used in this study. However, above 40 N applied load the coefficient of friction increases. The specific wear rate for PA 46 + 30%GFR and PA 66 against PPS + 30%GFR polymer composite counterpart are about in the order of 10−13 m2/N while the specific wear rate for PA 46 + 30%GFR and PA 66 against PA 46 + 30%GFR polymer composite counterpart are in the order of 10−14 m2/N. For PA 46 + 30%GFR composite and unfilled PA 66 polymers tested the specific wear rate values increased with the increment of load. The highest specific wear rate is for unfilled PA 66 against PPS + 30%GFR with a value of 2.81 × 10−13 m2/N followed by PA 66 against PA 46 + 30%GFR with a value of 2.26 × 10−13 m2/N. The lowest wear rate is PA 46 + 30%GFR polymer composite against PA 46 + 30%GFR polymer composite counterpart with a value of 3.19 × 10−14 m2/N. The average specific wear rates for unfilled PA 66 against PA 46 + 30%GFR is 80 times higher than PA 46 + 30%GFR wear rate while specific wear rates for unfilled PA 66 against PPS + 30%GFR is 100 times higher than that of PA 46 + 30%GFR wear rate. From point view of tribological performance, PA 46 + 30%GFR is a more suitable engineering thermoplastic composite materials for electrical contact breaker applications.Research limitations/implications– In the present work, tribological tests were performed only at room temperature under three different loads and a sliding speed. This is the limitation of the work.Practical implications– This work is easily used for industrial polyamides to check their tribological behaviours.Originality/value– This is an original and experimental study and it will be useful both for academicians and for industrial sides. VL - 60 IS - 4 SN - 0036-8792 DO - 10.1108/00368790810881542 UR - https://doi.org/10.1108/00368790810881542 AU - Unal H. AU - Findik F. PY - 2008 Y1 - 2008/01/01 TI - Friction and wear behaviours of some industrial polyamides against different polymer counterparts under dry conditions T2 - Industrial Lubrication and Tribology PB - Emerald Group Publishing Limited SP - 195 EP - 200 Y2 - 2024/05/14 ER -