TY - JOUR AB - Purpose– The purpose of this paper is to provide a modeling perspective relevant to the use of cathodic prevention (CPre) for unconventional concrete in salt‐laden environment.Design/methodology/approach– Based on the experimentally obtained concrete resistivity and chloride diffusion coefficient data, numerical studies with the Nernst‐Planck equations were conducted to investigate the influence of applied voltage (magnitude, direction, and interruption), surface chloride concentration, and concrete mix design on the effectiveness of cathodic prevention and the distribution of ionic species in protected concrete.Findings– The modeling results revealed that the direction of applied electric voltage has significant effect on the distributions of electrical potential and hydroxyl ions in the reinforced concrete, confirming the benefits of cathodic prevention in significantly increasing hydroxyl concentration near rebar and in slowing down the ingress of chloride ingress into concrete. The performance of intermittent CPre was found to be constrained by the variations in concrete resistance from the anode to the cathode. The model was also useful in illustrating the temporal and spatial evolutions on rebar surface in terms of oxygen, hydroxyl and chloride concentrations and electrical potential of top rebar, as well as such evolutions in concrete domain in terms of concrete resistivity and current density for each mix design.Originality/value– The results reported herein shed light on the fundamental processes defining the performance of CPre for new unconventional concrete in salt‐laden environment. VL - 59 IS - 3 SN - 0003-5599 DO - 10.1108/00035591211224663 UR - https://doi.org/10.1108/00035591211224663 AU - Liu Yajun AU - Shi Xianming PY - 2012 Y1 - 2012/01/01 TI - Modeling cathodic prevention for unconventional concrete in salt‐laden environment T2 - Anti-Corrosion Methods and Materials PB - Emerald Group Publishing Limited SP - 121 EP - 131 Y2 - 2024/09/23 ER -