To read this content please select one of the options below:

Uncertainty evaluation and optimization of INS installation measurement using Monte Carlo Method

Qing Wang (The State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou, China)
Peng Huang (The State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou, China)
Jiangxiong Li (The State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou, China)
Yinglin Ke (The State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou, China)

Assembly Automation

ISSN: 0144-5154

Article publication date: 3 August 2015

369

Abstract

Purpose

The purpose of this paper is to increase the measurement accuracy of assembly deviations of an inertial navigation system, a new evaluation and optimal method of assembly metrology system is proposed, which takes into account the uncertainty from laser tracker hardware and coordinate system transformation, and is based on the Monte Carlo method.

Design/methodology/approach

The uncertainty model of the laser tracker is established and its parameters are obtained from the known repeated test data by kriging interpolation and the least squares method. The errors of coordinate transformation are reduced by using a weighted point matching method, and the uncertainty of the transformation parameters is obtained based on the generalized inverse theory. The weighting coefficients of each reference point are optimized by the particle swarm optimization method according to the assembly requirements.

Findings

The experiment results show that measurement error and predicted results match well, and the assembly deviation uncertainty of large component is reduced by about 10 per cent compared with the singular value decomposition method.

Originality/value

This paper proposes a method to evaluate and eliminate the influence of random errors of the laser tracker during evaluation process of coordinate translation parameters and assembly deviations. The proposed method would be useful to improve the assembly measurement accuracy through less measurement times.

Keywords

Acknowledgements

This work was supported by the National Natural Science Foundation of China (Grant No. 51375442) and the Science Fund for Creative Research Groups of National Natural Science Foundation of China (No.51221004). The authors would also like to thank the editors and the anonymous referees for their insightful comments.

Citation

Wang, Q., Huang, P., Li, J. and Ke, Y. (2015), "Uncertainty evaluation and optimization of INS installation measurement using Monte Carlo Method", Assembly Automation, Vol. 35 No. 3, pp. 221-233. https://doi.org/10.1108/AA-08-2014-070

Publisher

:

Emerald Group Publishing Limited

Copyright © 2015, Emerald Group Publishing Limited

Related articles